• 제목/요약/키워드: Flexural

검색결과 5,058건 처리시간 0.032초

Full Zirconia Crown용으로 사용되는 block의 제조사의 굴곡강도와 임상작업후의 굴곡강도에 관한 연구 (The Study of Flexural Strength of Full Zirconia Crown using Block after Clinical Work)

  • 정효경;곽동주
    • 대한치과기공학회지
    • /
    • 제33권4호
    • /
    • pp.283-289
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate flexural strength of full zirconia crown using block after clinical work. Methods: The three point bending test was used to measure the flexural strength of zirconia block. Statistical analysis was done using the Statistical Package for Social Sciences version 19.0 for Windows. As for the analysis methods, the study used analysis of variance, Tukey's test. Results: The ave Rage value of flexural strengths of WIELAND, Zirkonzahn, Hass, D-MAX were 516.2 MPa, 612.6MPa, 566.2MPa, 744.6MPa. The ave Rage value of Surface Roughness of WIELAND, Zirkonzahn, Hass, D-MAX were 0.39Ra, 0.33Ra, 0.33Ra, 0.47Ra. Conclusion: Flexural strength of zirconia block decreased after clinical work. Flexural strength of zirconia block is equal to or higher than flexural strength of dental metal, so zirconia block can be used as dental material.

Flexural and shear behavior of large diameter PHC pile reinforced by rebar and infilled concrete

  • Bang, Jin-Wook;Lee, Bang-Yeon;Kim, Yun-Yong
    • Computers and Concrete
    • /
    • 제25권1호
    • /
    • pp.75-81
    • /
    • 2020
  • The purpose of this paper is to provide an experimental and analytical study on the reinforced large diameter pretensioned high strength concrete (R-LDPHC) pile. R-LDPHC pile was reinforced with infilled concrete, longitudinal, and transverse rebar to increase the flexural and shear strength of conventional large diameter PHC (LDPHC) pile without changing dimension of the pile. To evaluate the shear and flexural strength enhancement effects of R-LDPHC piles compared with conventional LDPHC pile, a two-point loading tests were conducted under simple supported conditions. Nonlinear analysis on the basis of the conventional layered sectional approach was also performed to evaluate effects of infilled concrete and longitudinal rebar on the flexural strength of conventional LDPHC pile. Moreover, ultimate strength design method was adopted to estimate the effect of transverse rebar and infilled concrete on the shear strength of a pile. The analytical results were compared with the results of the bending and shear test. Test results showed that the flexural strength and shear strength of R-LDPHC pile were increased by 2.3 times and 3.3 times compared to those of the conventional LDPHC pile, respectively. From the analytical study, it was found that the flexural strength and shear strength of R-LDPHC pile can be predicted by the analytical method by considering rebar and infilled concrete effects, and the average difference of flexural strength between experimental results and calculated result was 10.5% at the ultimate state.

커플러 이음 철근을 사용한 철근콘크리트 보의 휨 거동에 대한 실험적 연구 (An Experimental Research on the Flexural Behavior of Concrete Beams with Lock Joint Coupler Bars)

  • 박선규;이괄;고원준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권3호
    • /
    • pp.197-204
    • /
    • 2000
  • Tensile strength (stress) of bar splice is important in the research of mechanical behavior of reinforced concrete structures-beam, column etc.- with bar splice. The purpose of this research is to evaluate the flexural behavior - deflection of beam specimens, strain of main bars - of reinforced concrete beam with Lock Joint Coupler. To make a comparative research, reinforced concrete beam specimens with normal deformed bar and lap splice are tested and analyzed. Test results, Comparing a deflection of three types flexural specimens, a flexural specimen with Lock Joint Coupler is 40% greater than the other flexural specimens. At the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 50% less, and vice versa, at the point of 14cm far from the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 9% larger than the strain of main bar(D29) which calculated using the classical flexure theory. A discords, between a deflection behavior of the flexural specimens and a strain of the main bar, are caused by the difference of strain between the lock joint coupler and main bar, near the lock joint coupler. So, additional research is need to verify as stated above discords.

  • PDF

A minimum ductility design method for non-rectangular high-strength concrete beams

  • Au, F.T.K.;Kwan, A.K.H.
    • Computers and Concrete
    • /
    • 제1권2호
    • /
    • pp.115-130
    • /
    • 2004
  • The flexural ductility of solid rectangular reinforced concrete beams has been studied quite extensively. However, many reinforced concrete beams are neither solid nor rectangular; examples include T-, ${\Gamma}$-, ${\Pi}$- and box-shaped beams. There have been few studies on the flexural ductility of non-rectangular reinforced concrete beams and as a result little is known about the possible effect of sectional shape on flexural ductility. Herein, the effect of sectional shape on the post-peak flexural behaviour of reinforced normal and high-strength concrete beams has been studied using a newly developed analysis method that employs the actual stress-strain curves of the constitutive materials and takes into account the stress-path dependence of the stress-strain curve of the steel reinforcement. It was revealed that the sectional shape could have significant effect on the flexural ductility of a concrete beam and that the flexural ductility of a T-, ${\Gamma}$-, ${\Pi}$- or box-shaped beam is generally lower than that of a solid rectangular beam with the same overall dimensions and the same amount of reinforcement provided. Based on the numerical results obtained, a simple method of ensuring the provision of a certain minimum level of flexural ductility to non-rectangular concrete beams has been developed.

Effect of different coloring liquids on the flexural strength of multilayered zirconia

  • Yu, Na-Kyoung;Park, Mi-Gyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권4호
    • /
    • pp.209-214
    • /
    • 2019
  • PURPOSE. The purpose of this study was to evaluate the effect of two coloring liquids (aqueous and acid-based coloring liquids) and the position of multilayered zirconia on the flexural strength of multilayered zirconia. MATERIALS AND METHODS. The multilayered zirconia specimens were divided into upper and lower positions. The specimens were divided into three subgroups (n=10): non-shaded, acid-based coloring liquid, and aqueous coloring liquid. The specimens were cut using a milling machine and were immersed in either a acid-based coloring liquid or aqueous coloring liquid 2 times for 5 seconds. The specimens were sintered in a sintering furnace according to the manufacturer's introduction. The flexural strength of the specimen was measured using a universal testing machine and the surface of the specimen was observed using a field emission scanning electron microscope. RESULTS. The flexural strength of multilayered zirconia was 400 - 500 MPa. There was no statistically significant difference among all groups (P>.05).The flexural strength of the multilayered zirconia was not influenced by the kind of coloring liquid used (P>.05). The flexural strength of the multilayered zirconia colored with the coloring liquids was not influenced by its position (P>.05). CONCLUSION. The different coloring liquid application did not affect the flexural strength of multilayered zirconia of all positions.

하이브리드 조립형 보강 기법을 적용한 철근콘크리트 보의 휨 성능 평가에 관한 실험적 연구 (An Experimental Study on Flexural Performance of RC Beams Reinforced With Hybrid Prefabricated Retrofit Method)

  • 문상필;이성호;이영학;김민숙
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.131-139
    • /
    • 2020
  • In this paper, the hybrid prefabricated retrofit method is suggested and examined. Six specimens were manufactured in order to evaluate their flexural performance of RC beams. Test parameters include the added beam depth, the thickness of bottom plate, the number of the steel plate with openings. The effects of these parameters on the flexural performance of reinforced concrete beams were examined. The load-deflection behavior and modes of cracks are presented from the test results. At the test result, the flexural capacity and the ductility of the hybrid prefabricated retrofit method was increased satbly. Also, comparing the flexural performance of RC beam and retrofitted RC beams, it was increased that the flexural strength is about 3.3 times, the ductility is about 2.55 times, and energy dissipation capacity is about 7.34 times.

Research on flexural bearing capacity of cold-formed thin-walled steel and reinforced concrete sandwich composite slabs

  • Qiao, Wentao;Huang, Zhiyuan;Yan, Xiaoshuo;Wang, Dong;Meng, Lijun
    • Steel and Composite Structures
    • /
    • 제45권2호
    • /
    • pp.219-230
    • /
    • 2022
  • The aim of this paper is to study the mechanical behaviors of the cold-formed thin-walled steel and reinforced concrete sandwich composite slab (CTS&RC-SCS) under vertical loads and to develop the calculation methods of its flexural bearing capacity and section stiffness. Two CTS&RC-SCS specimens were designed and manufactured to carry out the static loading test, and meanwhile, the numerical simulation analyses based on finite element method were implemented. The comparison between experimental results and numerical analysis results shows that the CTS&RC-SCS has good flexural capacity and ductility, and the accuracy and rationality of the numerical simulation analysis are verified. Further, the variable parameter analysis results indicate that neither increasing the concrete strength grade nor increasing the thickness of C-sections can significantly improve the flexural capacity of CTS&RC-SCS. With the increase of the ratio of longitudinal bars and the thickness of the composite slab, the flexural capacity of CTS&RC-SCS will be significantly increased. On the basis of experimental research and numerical analysis above, the calculation formula of the flexural capacity of CTS&RC-SCS was deduced according to the plastic section design theory, and section stiffness calculation formula was proposed according to the theory of transformed section. In terms of the ultimate flexural capacity and mid-span deflection, the calculated values based on the formulas and the experimental values are in good agreement.

비정질 강섬유보강콘크리트의 휨성능 특성 (Flexural Performance Characteristics of Amorphous Steel Fiber-Reinforced Concrete)

  • 구동오;김선두;김희승;최경규
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.483-489
    • /
    • 2014
  • 이 연구에서는 ASTM C 1609을 따라서 비정질 강섬유보강콘크리트의 휨실험을 수행하였고, 이를 바탕으로 휨성능을 평가하였다. 비정질 강섬유는 기존의 일반 강섬유와 달리 얇은 두께, 거친 표면의 특성을 가지고 있다. 주요한 실험변수는 섬유 종류(비정질 강섬유, 일반 강섬유), 섬유 혼입률(0.25, 0.50, 0.75%) 그리고 콘크리트 압축강도(27, 50 MPa)이다. 실험 결과에 근거하여 비정질 강섬유와 일반 강섬유보강콘크리트의 휨강도와 휨인성을 분석하였고, 그 결과 일반 강섬유보강콘크리트의 경우 주로 휨인성이 증가하였으나 비정질 강섬유보강콘크리트의 경우 휨강도와 인성을 모두 증가하는 것으로 나타났다.

Al Shee/CFRP 다적층 하이브리드 복합재료의 굴곡강도에 미치는 카본섬유 체적률 및 배열방향 영향 (The Influence of Volume Fraction and Fiber Orientation of CERP Layer on Flexural properties of A17075/CFRP Multi-Layered Hybrid Laminate Material)

  • 유재환
    • 한국안전학회지
    • /
    • 제19권4호
    • /
    • pp.31-35
    • /
    • 2004
  • The A17075/CFRP multi-layered hybrid laminate material consists of the alternating A17075-T6 sheets and carbon/epoxy prepregs of M40 fade. The influence of volume fraction and fiber orientation of A17075/CFRP layer on flexural properties of A17075/CFRP laminate alternating A17075-T6 and carbon/epoxy prepreg was investigated. The results obtained from the experimental analysis are as follows: 1. In the $0^{\circ}$ fiber orientation, the mont of increase of the flexural rigidity was $20.5\%$ at the $26.5\%$ volume fraction and $38.0\%\;at\;the\;35.7\%$ volume fraction compared with the flexural rigidity level(20.0GPa) of the $10\%$ volume fraction of CFRP. 2. In the $\pm45^{\circ}$ fiber orientation the amount of decrease of the flexural rigidity was $23.5\%\;at\;the\;20.0\%$ volume fraction and $31.5\%\;at\;the\;33.3\%$ volume fraction compared with the flexural rigidity level of the $10\%$ volume fraction of CFRP. 3. In the $0^{\circ}$ fiber orientation, the flexural strength was 481.5MPa at the $10\%$ volume fraction of CFRP and 583.8MPa at the $26.5\%$ volume fraction and 653.7MPa at the $35.7\%$ volume faction. 4. In the $\pm45^{\circ}$ fiber orientation, the flexural strength was 354.0MPa at the $20.0\%$ volume fraction of CFRP and 340.5MPa at the $33.3\%$ volume fraction.

집중하중 조합에 의한 섬유 보강 콘크리트 바닥슬래브의 설계 휨 내력 (Effect of the Combination of Point Loads on the Design Flexural Capacity for Fiber Reinforced Concrete Floor Slab)

  • 이종한;조백순;김정식;조범구;김한식
    • 한국건설순환자원학회논문집
    • /
    • 제4권1호
    • /
    • pp.47-54
    • /
    • 2016
  • 본 연구에서는 섬유 보강 콘크리트 바닥슬래브의 주요 설계하중인 선반하중과 이동하중에 의한 휨 내력을 평가하였다. 설계기준을 바탕으로 각 하중의 크기와 작용면적을 정의하였으며, 그 관계를 분석하였다. 단일하중에 의해서는 슬래브 경계면에서 휨 내력이 평가되어야 하며, 슬래브 두께 180mm 이상, 콘크리트 강도 35MPa 이상일 때는 최소 등가 휨강도비로써 휨 내력을 충분히 만족하였다. 조합하중에 의해서는 선반하중간의 조합이 가장 큰 등가 휨강도비를 요구하였으며, 선반하중과 이동하중의 조합은 선반하중간의 조합에 비해서는 작게 평가되었고, 단일 하중에 비해서는 크게 평가되었다. 본 연구결과 섬유 보강 콘크리트 바닥슬래브의 휨 설계는 하중 조합에 의한 내력 평가가 필요함을 확인하였다.