• Title/Summary/Keyword: Flexible screw

Search Result 22, Processing Time 0.028 seconds

A Development and Estimation about Flexible Rod for Flexibility of Pedicle Screw System (인공 척추경 나사시스템의 유연성 증가를 위한 플렉시블 로드의 개발 및 평가)

  • Yoon, Gil-Sang;Sohn, Jong-In;Kim, Gun-Hee;Seo, Tae-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1775-1780
    • /
    • 2011
  • In this paper, it is analyzed about the mechanical characteristics of pedicle screw system which is a artificial implant for surgery to treatment serious lumbar vertebra diseases. The disk of lumbar vertebra to be fixed by pedicle screw system shows regressive phenomena. But if flexible rod, to give a flexibility(under 6 degree) to fixable disk is applied, it can protect against the degeneration of disk. This research is carried out a mechanical characteristic of pedicle screw system used flexible rod through finite elements analysis, and then flexible rod system was verified about safe movement through compression, tension and torsion test which is the pedicle screw system official recognition test(ASTM F 1717).

Strength of Furniture Joints Constructed with PVC Anchor and Screw (PVC 앵커와 나사못으로 구성(構成)한 가구류(家具類) 접합부(接合部)의 강도(强度))

  • Lee, Phil-Woo;Park, Hee-Jun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.22-30
    • /
    • 1991
  • This study was carried out to determine the Joint characteristic of L-type specimens. L-type specimens were made of two kinds uf solid woods(Antiaris, Sepetir) and three kinds of wood based materials(plywood, particleboard, medium density fiberboard). They were constructed with PVC anchor and screw, and were discussed with joint strength and stiffness coefficients. The obtained results were as follows: 1. Bending strength showed very high increasing rate from one to three used PVC anchor and screw but was a little rise from three to four used PVC anchor and screw in solid wood. However. in wood based materials, it was unchanged without increasing rate or slight decreased from three to four used PVC anchor and screw. 2. The stiffness coefficients, or Z-values, were in the range from $4.704\times10^{-4}$ to $1.864\times10^{-3}$(rad/kgf-cm). They showed $10^{-3}$ level in one PVC anchor and screw but $10^{-4}$ level in two, three. four PVC anchor and screw. Accordingly, they indicated flexible joints in one PVC anchor and screw and relatively stable joints in two, three. four PVC anchor and screw. 3. Measured ultimate bending moments were 258.70kgf-cm in plywood and 142.68kgf-cm in medium density fiberboard. 4. Comparing with dowel joint. the joint strength used PVC anchor screw was inferior to 8mm and 10mm dowel diameter but differ little from 6mm dowel diameter.

  • PDF

The Role of the Narrow Band Imaging for Lung Cancer (폐암에서의 협대역 내시경의 역할)

  • Park, Jinkyeong;Choi, Chang Min
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.1
    • /
    • pp.5-8
    • /
    • 2011
  • The proliferation of new technologies has significantly enhanced the diagnostic capabilities of flexible bronchoscopy compared with traditional methods. Narrow band imaging (NBI), an optical technique in which filtered light enhances superficial neoplasms based on their neoangiogenic patterns, was developed to screen for central intraepithelial moderate or severe dysplasia, carcinoma in situ (CIS), and microinvasive neoplasia in patients at risk for lung cancer. Because angiogenesis occurs preferentially in dysplastic and neoplastic lesions, NBI may identify early dysplastic lesions better than white light bronchoscopy (WLB) currently in use. NBI bronchoscopy can be used not only to detect precancerous lesions, but also to screen for cancerous lesions. We prospectively evaluated 101 patients with suspected lung cancer between July 2009 and June 2010. All were previously scheduled for flexible bronchoscopy CT scans. Abnormal NBI was defined by Shibuya's descriptors (tortuous, dotted, or spiral and screw patterns). Biopsies of 132 lesions in 92 patients showed that 78 lesions (59.1%) were malignant and 54 (40.9%) were benign. The diagnostic sensitivity of bronchoscopy in detecting malignancy was 96.2% (75/78). When assorted by lesion pattern, the sensitivity and specificity of NBI bronchoscopy in detecting malignancies were 69.2% (54/78) and 96.3% (52/54), respectively, for the spiral and screw pattern and 14.1% (11/78) and 96.3% (52/54), respectively, for the dotted pattern. Unexpectedly, additional cancerous lesions were detected in five patients (2 dotted and 3 spiral and screw). As a screening tool for malignant lesions, NBI bronchoscopy should assess combinations of all three lesion. The dotted and spiral and screw patterns may be helpful in determining which lesions should be biopsied. NBI bronchoscopy may be useful not only for the diagnosis of early-stage lung cancer but also for more accurate local staging of lung cancer.

  • PDF

Translational control of a one link flexible arm

  • Lee, Seong-Cheol;Seiji Chonan;Hikaru Inooka
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.577-582
    • /
    • 1989
  • This is a study of the translational end-point control of a single link flexible arm-with a tip mass. The beam is mounted on a translational mechanism driven by the ball screw, whose rotation is controlled by DC servomotor. The problem of shifting the end-point from its initial position to the commanded position is studied analytically both for the open-loop control subjected to some path functions and for the closed-loop control using the feedback of the tip information.

  • PDF

Mechanical Characterization of the Pedicle Screw System for Thoracolumbar Spine (흉요추용 척추경 나사못시스템의 기계적 특성)

  • 이효재;최화순;안면환;송정일
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.17-26
    • /
    • 2002
  • The purpose of this study was to investigate the important Parameters of the Pedicle screw by estimating the mechanical characteristics of screws under static and dynamic loads. Methodology for estimating Parameters under static load was proposed. It was also shown that the fatigue life of the one-level system could be increased by changing the shape of screws. Load parameters of the single pedicle screw were friction force. bending moment. and holding force. The test results of the one-level system could be inferred from teat results of the sin91e screw under bending force Fatigue life of the one-level system with flexible rod was longer than that of the upper Part test without rod . Considering the drop of flexibility of the rod due to muscles and ligament, fatigue life of the one-level system could be estimated b? that of the single screw.

Coupled Flexible Multi-Body Dynamics and Controller Analysis of Machine Tool (공작기계의 유연 다물체 동역학 및 제어기 연계해석)

  • Kim, Dong-Man;Kim, Dong-Hyun;Park, Kang-Kyun;Choi, Hyun-Chul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.3
    • /
    • pp.307-312
    • /
    • 2010
  • In this study, advanced computational technique for mechatronic analysis has been developed for the efficient design and test of typical machine tool models. Flexible multi-body dynamic (FMBD) analysis method combined with motion controller including control logics is used to simulate typical operation conditions. The present FMBD machine tool model is composed of flexible column structure, rigid body spindle, vertical motion guide (arm) and screw elements. Driving motor clement with rotating degree-of-freedom is interconnected and governed by the designed Matlab Simulink control logic, and then the position of the spindle is feedback into the control logic. It is practically shown from the results that the investigation of designed machine tools with controller can be effectively conducted and verified.

PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY DIFFERENT TYPE ENDOSSEOUS IMPLANTS (골내 임플랜트의 종류에 따른 광탄성 응력 분석)

  • Chung Chae-Heon;Chang Doo-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.661-678
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of endosseous implants. This investigation evaluated the stress patterns in rectangular photoelastic models produced by four different types of dental implants such as $Br\ddot{a}nemark$, screw type of Steri-Oss, blade type of Steri-Oss, IMZ with IMC and resin tooth using the techniques of quasi-three dimensional photoelasticity. All prostheses were casted in the same nonprecious alloy and were cemented or screwed on their respective implants and abutments. 20 kg of vertical load was applied on the central fossa of casted crown and 16 kg of inclined had was applied on the top third of distal surface of casted crown respectively. The results were as follows : 1. Under the vertical load, screw implants of Steri-Oss and $Br\ddot{a}nemark$ showed increasing stress condition between and around the screw threads along the implant lateral surface and cylindrical implant of IMZ showed the less stress condition along the lateral surface with concentration of stress mostly near the root apex. 2. Under the vertical load, the stress of Steri-Oss blade was distributed uniformly at the alveolar bone under the broad blade. 3. Under the inclined load, the stress concentration of Steri-Oss screw and $Br\ddot{a}nemark$ was developed highly around the mesiocervical bone area on the contralateral side to force application. The stress of $Br\ddot{a}nemark$ with flexible gold glod was more concentrated in the cervical bone area than that of Steri-Oss with stiff screw. 4. Under the inclined load, the stress of Steri-Oss blade broadly was distributed around the mesioceivical bone area and the lower and mesial bone area of the blade. 5. Under the Inclined load, IMZ implant showed the gap between c개wn and fixture due ta deformation of the IMC and IMZ was lower in stress concentration developed around the mesiocervical bone area than $Br\ddot{a}nemark$ and Steri-Oss screw. 6. Under the inclined load, the stress magnitude induced in the mesiocervical bone area of implants was in order of $Br\ddot{a}nemark$, Steri-Oss strew, IMZ and Stsri-Oss blade. 7. Tilting forces as compared to axial forces exerted greater magnitude of stress in the cervical bone area of the implant. 8. In respect of stress distribution, Steri-Oss blade was superior than any other implants and in respect of the stability by horizontal lone, IMB and $Br\ddot{a}nemark$ was inferior than any other implants.

  • PDF

Biomechanical Efficacy of a Combined Flexible Cage with Pedicle Screws with Spring rods: A Finite Element Analysis (Spring rod를 사용한 척추경 나사못과 동반 시술된 Flexible cage의 생체역학적 효과)

  • Kim, Y.H.;Park, E.Y.;Kim, W.H.;Hwang, S.P.;Park, K.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • Recently, flexible cages have been introduced in an attempt to absorb and reduce the abnormal load transfer along the anterior parts of the spine. They are designed to be used with the pedicle screw systems to allow some mobility at the index level while containing ROM at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the flexible cage when combined with pedicle screws with flexible rods. The post-operated models were constructed by modifying the L4-5 of a previously-validated 3-D FE model of the intact lumbar spine (L2-S1): (1) Type 1, flexible cage only; (2) Type 2, pedicle screws with flexible rods; (3) Type 3, interbody fusion cage plus pedicle screws with rigid rods; (4) Type 4, interbody fusion cage plus Type 2; (5) Type 5, Type 1 plus Type 2. Flexion/extension of 10 Nm with a compressive follower load of 400N was applied. As compared to the Type 3 (62~65%) and Type 4 (59~62%), Type 5 (53~55%) was able to limit the motion at the operated level effectively, despite moderate reduction at the adjacent level. It was also able to shift the load back to the anterior portions of the spine thus relieving excessively high posterior load transfer and to reduce stress on the endplate by absorbing the load with its flexible shape design features. The likelihood of component failure of flexble cage remained less than 30% regardless of loading conditions when combined with pedicle screws with flexible rods. Our study demonstrated that flexible cages when combined with posterior dynamic system may help reduce subsidence of cage and degeneration process at the adjacent levels while effectively providing stability at the operated level.

Finite element analysis for dynamic behavior of a machine tool structure fed in open loop control (개루프제어로 이송되는 공작기계 구조물의 동적 거동을 위한 유한 요소 해석)

  • Choi, Jin-Woo;Lee, Tae-Hong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.5
    • /
    • pp.596-602
    • /
    • 2010
  • In this study, a fmite element model was developed for analysis of feeding a structure in open loop control The finite element analysis (FEA) can simulate dynamic behavior of the structure of a machine tool rapidly traveling with a screw feeding driving system. The feeding mechanism was implemented with screw element of the FEA tool used in this study. The procedure was developed for the dynamic transient FEA. First, motion parameters such as jerk and velocity were introduced for the structure to be fed in open loop control When its traveling distance was determined, set-points for the distance were generated based on the motion parameters. The set-points were applied to the FE model constructed for the traveling structure. The FEA was executed and evaluated. In this study, the FEA procedure was applied to the column of a machine tool and the dynamic behavior of the column was evaluated. The FEA helps in evaluation of the motion characteristics of a structure. The convergence time of the structure vibration posterior to feeding termination can be estimated and the stiffness of the flexible structure is also evaluated against jerk, and acceleration. It provides the feeding force which is helpful in selection of the feeding motor.