• 제목/요약/키워드: Flexible Wedge Gate

검색결과 5건 처리시간 0.019초

차압이 모터구동 Flexible Wedge형 게이트밸브의 성능에 미치는 영향 (Effect of Differential Pressure on the Performance of Motor Operated Flexible Wedge Gate Valve)

  • 김대웅;유성연
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.151-158
    • /
    • 2007
  • The mechanism of power transmission from motor torque to stem thrust and the operation characteristic of each stroke position are analyzed using the diagnostic signal, and effects of differential pressure on the performance of motor operated flexible wedge gate valve are investigated. Test facility consists of 76 mm motor operated valve(flexible wedge type), pump and pipe system. Static and dynamic test are performed separately, and two differential pressure conditions are applied in the dynamic test. To evaluate the performance of valve, test signals for the torque, thrust, current, voltage and stroke length are acquired by using UDS which is diagnosis device for motor operated valve, and each diagnostic signal is analyzed and compared. The characteristic of valve performance factors such as stem factor, rate of loading, valve factor, are evaluated, and these factors are found to be severely influenced by the fluid differential pressure.

모터구동 Flexible Wedge형 게이트밸브의 밸브 성능인자 Bounding Value에 대한 연구 (A Study on the Bounding Value of Valve Performance Parameters for Motor Operated Flexible Wedge Gate Valve)

  • 김대웅;유성연;박성근;이도환
    • 한국유체기계학회 논문집
    • /
    • 제10권5호
    • /
    • pp.46-53
    • /
    • 2007
  • Stem friction coefficient and valve factor are very important parameters for the evaluation of valve performance. In this study, the characteristics of stem friction coefficient and valve factor are analyzed, and thor bounding value is determined. The hydraulic testing is performed for many flexible wedge gate valves in the plant and statistical method is applied to the determination of bounding value. According to the results of this study, stem friction coefficient does not change much with differential pressure, and the bounding value of closing stroke is higher than that of opening stroke. The valve factor of valves with high differential pressure is higher than that of valves with medium differential pressure. It means valve factor is more sensitive to the differential pressure than the stem friction coefficient. Valve factor of the closing stroke is higher than that of opening stroke due to piston effect.

Flexible Wedge Gate 밸브의 운전 성능향상 방안에 관한 연구 (A Study for the Improvement Method of Flexible Wedge Gate Valve Operation Capability)

  • 김대웅;이도환;강신철;김인환;박성근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.644-651
    • /
    • 2001
  • The purpose of this study is to develop the improvement method of MOV(Motor Operated Valve) operability without major modification or change of MOV which needs a great expense and manpower. We studied valve stem lubrication, stem packing thrust and actuator control switch which could give an major effect to MOV operability, and found the some consequences. First, the stem/stem-nut friction coefficient and stem factor is significantly effected by stem lubrication state. Second, the measured packing thrust value is appeared higer than the design value for tested valves and the preparation of optimal value selection criteria is needed. Finally, optimization of MOV control switch is another major factor for MOV operability and structual integrity.

  • PDF

압력잠김 및 열고착 현상 발생가능 밸브의 선정 (Selection of Valves Susceptible to Pressure Locking and Thermal Binding)

  • 이성노;안진근;김석범
    • 한국유체기계학회 논문집
    • /
    • 제10권5호
    • /
    • pp.20-26
    • /
    • 2007
  • Some gate valves are susceptible to pressure locking and thermal binding which prevent the safety function. The safety related gate valves susceptible to pressure locking and thermal binding shall be identified and taken preventive actions to ensure the safety function. The identification of the gate valves susceptible to pressure locking and thermal binding needs the evaluation of system design, valve and piping arrangement, test requirements, and operating conditions. Application of preventive methods should consider the system safety function, applicability, effectiveness, interface with system design, and cost. The selection procedure of valves susceptible to pressure locking and thermal binding can be effectively used in industry including nuclear power plants. In order to prevent the pressure locking, the hole can be drilled through the one disc of upstream side or down stream and the external equalizing line can be installed from bonnet to downstream or upstream. The double disc parallel seat valve type can be used instead of flexible wedge gate valve to prevent the thermal binding. The identification of gate valves susceptible to pressure locking and thermal binding, and preventive actions will meet the regulatory requirements and enhance the availability and safety of plants.

PPM을 이용한 원자력 발전소 모터구동밸브의 안전성 평가 (A Safety Evaluation of Motor-Operated Valves of Nuclear Power Plants By Using PPM)

  • 박수기;김대웅;정희권;박성근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.718-723
    • /
    • 2001
  • PPM (Performance Prediction Methodology) developed by EPRI was introduced and applied to calculate the stem thrust of 3 and 4 inches flexible-wedge gate valves. The calculated stem thrusts of open and close strokes including cracking were compared with the results measured at in-situ differential pressure tests. The comparison has shown that PPM is an extremely conservative method to predict the minimum required stem thrust to operate motor-operated valves in a design basis accident condition of nuclear power plants.

  • PDF