• Title/Summary/Keyword: Flexible Flywheel

Search Result 4, Processing Time 0.019 seconds

Validation of Flexible Rotor Model for a Large Capacity Flywheel Energy Storage System (유한요소법을 이용한 대용량 플라이휠 에너지 저장 장치의 연성 회전체 모델의 검증)

  • Yoo, Seong-Yeol;Park, Cheol-Hoon;Choi, Sang-Kyu;Lee, Jeong-Pil;Noh, Myoung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1096-1101
    • /
    • 2008
  • When we design a controller for the active magnetic bearings that support a large rotor, it is important to have an accurate model of the rotor. For the case of the flywheel that is used to store energy, an accurate rotor model is especially important because the dynamics change with respect to the running speed due to gyroscopic effects. In this paper, we present a procedure of obtaining an accurate rotor model of a large flywheel energy storage system using finite-element method. The model can predict the first and the second bending mode which match well with the experimental results obtained from a prototype flywheel energy storage system.

A Study on Improvement of the Power Plant Vibration for the Noise Reduction and the Sound Quality Improvement in the Compartment. (차량 실내소음 저감 및 음질향상을 위한 POWER PLANT 진동 개선에 관한 연구)

  • 이상권;최병욱;여승동
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.77-88
    • /
    • 1993
  • This paper shows the methods about an improvement of the sound quality, which is improvement for automobil market recently. Especially, the rumble noise in the passenger compartment makes driver uncomfortable. For an improvement of the rumble noise, in this paper, the increase of the number of balance weight of the crank shaft(from 4 to 8), the vibration constrainer of cylinder block and the flexible flywheel were applied to power plant. Among those kinds of applications, the application of the flexible flywheel to power plant makes not only the vibration of the engine mount boss reduce most effectly but also the interior noise. It also improves the sound quality and the rumble noise disappears in the passenger compartment.

  • PDF

A Novel Energy Storage System based on Flywheel for Improving Power System Stability

  • Wu, Jinbo;Wen, Jinyu;Sun, Haishun;Cheng, Shijie
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.447-458
    • /
    • 2011
  • In this paper, a novel flywheel energy storage device, called the flexible power conditioner, which integrates both the characteristics of the flywheel energy storage and the doubly-fed induction machine, is proposed to improve power system stability. A prototype is developed and its principle, composition, and design are described in detail. The control system is investigated and the operating characteristics are analyzed. The test results based on the prototype are presented and evaluated. The test results illustrate that the prototype meets the design requirement on power regulation and starting, and provides a cost-effective and effective means to improve power system stability.

Analysis of Control Stability and Performance of Magnetically-Levitated Flywheel Energy Storage System using Flexible Rotor Model (유연체 회전축 모델을 이용한 자기부상형 플라이휠 에너지 저장장치의 제어시스템 안정성 및 성능 해석)

  • Yoo, Seong-Yeol;Lee, Wook-Ryun;Bae, Yong-Chae;Noh, Myoung-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.258-263
    • /
    • 2009
  • This paper describes an analysis of the stability and performance of a large-capacity flywheel energy storage system (FESS) supported by active magnetic bearings. We designed and manufactured the system that can store up to 5kWh of usable energy at the maximum speed of 18,000 rpm. In order to analyze the stability of the systems accurately, we derived a rigid body rotor model, flexible rotor model using finite-element method, and a reduced-order model using modal truncation. The rotor model is combined with those of active magnetic bearings, amplifiers, and position sensors, resulting in a system simulation model. This simulation model is validated against experimental measurements. The stability of the system is checked from the pole locations of the closed-loop transfer functions. We also investigated the sensitivity function to quantify the robustness of the systems to the disturbances such as mass imbalance and sensor noises.

  • PDF