Feasibility of a Linear Diode Array Detector for Commissioning of a Radiotherapy Planning System

  • Seung Mo Hong;Uiseob Lee;Sung-woo Kim;Youngmoon Goh;Min-Jae Park;Chiyoung Jeong;Jungwon Kwak;Byungchul Cho
    • 한국의학물리학회지:의학물리
    • /
    • 제34권1호
    • /
    • pp.1-9
    • /
    • 2023
  • Purpose: Although ionization chambers are widely used to measure beam commissioning data, point-by-point measurements of all the profiles with various field size and depths are time-consuming tasks. As an alternative, we investigated the feasibility of a linear diode array for commissioning a treatment planning system. Methods: The beam data of a Varian TrueBeam® radiotherapy system at 6 and 10 MV with/without a flattening filter were measured for commissioning of an Eclipse Analytical Anisotropic Algorithm (AAA) ver.15.6. All of the necessary beam data were measured using an IBA CC13 ionization chamber and validated against Varian "Golden Beam" data. After validation, the measured CC13 profiles were used for commissioning the Eclipse AAA (AAACC13). In addition, an IBA LDA-99SC linear diode array detector was used to measure all of the beam profiles and for commissioning a separate model (AAALDA99). Finally, the AAACC13 and AAALDA99 dose calculations for each of the 10 clinical plans were compared. Results: The agreement of the CC13 profiles with the Varian Golden Beam data was confirmed within 1% except in the penumbral region, where ≤2% of a discrepancy related to machine-specific jaw calibration was observed. Since the volume was larger for the CC13 chamber than for the LDA-99SC chamber, the penumbra widths were larger in the CC13 profiles, resulting in ≤5% differences. However, after beam modeling, the penumbral widths agreed within 0.1 mm. Finally the AAALDA99 and AAACC13 dose distributions agreed within 1% for all voxels inside the body for the 10 clinical plans. Conclusions: In conclusion, the LDA-99SC diode array detector was found to be accurate and efficient for measuring photon beam profiles to commission treatment planning systems.

6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포 (Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator)

  • 윤주호;이철수;염하용
    • 대한방사선치료학회지
    • /
    • 제12권1호
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구 (Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws)

  • 김정기;최영민;이형힉;허원주
    • Radiation Oncology Journal
    • /
    • 제14권3호
    • /
    • pp.237-244
    • /
    • 1996
  • 목적 : 의료용 선형가속기의 Independent Collimator는 현재 광범위하게 사용되고 있다. 그러나 방사선량의 계산과 MU(Monitor Unit)의 계산에 사용되는 모든 기본 자료는 대칭 조사면를 기준으로 작성되었기 때문에 independent collimator를 사용한 비대칭적인 조사면의 경우 현재 사용하고 있는 계산 방식을 그대로 적용함에 무리가 있을 것으로 생각된다. 따라서 이러한 의문에 대한 체계적이고 과학적인 검토가 필요할 것으로 사료되어 본 연구를 진행하였다. 대상 및 방법 :본 연구는 Dual Photon Beam(6MV와 15MV)을 산출(産出)하는 선형가속기(Linac 1800, Varian Co)에서 collimator 사용시 산란 방사선의 총채로 표현되어지는 field size factor, beam qualify에 영향을 미치는 HVL와 PDD를 조사하였다. 먼저 field size factor는 water phantom(WP 600C Wellhofer, Germany)내의 Dmax에서 field size $3{\times}3cm$에서 $35{\times}35cm$까지의 방사선량의 변화를 square field로 $1cm^2$씩 증가시켜 가며 0.6cc ion chamber(NE 2571)로 측정하였다. Beam quality는 100cm SSD(source-surface distance)에서 $5{\times}5$, $10{\times}10$, $15{\times}15$$20{\times}20cm$ field size로 0, 3 및 10cm off-axis distance와 dmax 4, 10, 15 및 20cm의 깊이에서 측정하였다. Dose distribution을 분석하기 위하여 film densitometer와 water phantom(IC 10 ion chamber)을 사용, $10{\times}10cm$ field size에서 5, 10 및 15cm의 off-axis distance까지의 방사선량의 분포를 관찰하고 대칭 방사선 조사면와 비교 분석하여 실제 isodose 분포에 미치는 영향을 관찰하였다. 결과: 1) Relative field size factor는 중심 축에서 off-axis lateral distance에 따라 다양하게 변화하였는데 6MV X-선의 경우 최대 $3.1\%$, 15MV X-선의 경우 최대 $5\%$까지의 변화를 보였다. 이때 off-axis factor를 구하여 교정을 하였을 경우 중심 축의 field size factor와 거의 유사한 값에 도달할 수 있었다. 2) Beam qualify의 변화를 관찰하기 위한 실험에서 HVL는 off-axis distance가 멀어질수록 감소하였고 PDD도 off-axis distance가 멀어지고 측정 깊이가 깊어질수록 감소되는 현상을 보였다. 통상적인 방사선 치료시에 이용되는 $5{\times}5cm$ 이상의 field size와 15cm 이내의 깊이에서는 3cm 와 l0cm의 off-axis에서 6MV X-선은 평균 $0.5\%$$2\%$, 15MV X선은 $0.4\%$$1.4\%$의 감소 현상을 보여 큰 편차를 관찰할 수 없었다. 3) Isodose distribution은 off-axis distance가 멀어질수록 depth dose의 증가치가 감소되었으며 특히 central axis의 가장자리 부위에서는 isodose curve의 위축이 확연하였다. 결론 : Independent collimator를 사용하여 비대칭 방사선 치료를 할 경우 MU의 계산은 off-axis factor와 PDD 보정이 필수적이며 임상적으로는 중심 축에서의 과소조사에 대한 정밀한 주의가 필요할 것으로 사료된다.

  • PDF

용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가 (Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning)

  • 우헌;박장필;민제순;이제희;유숙현
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.115-121
    • /
    • 2013
  • 목 적: 최신 선형가속기와 새로운 평가 장비를 도입하게 되어 이를 임상에 적용하기 위한 준비과정 중 몇 가지 문제가 발생하여 유용성을 확인하는 과정을 분석함으로써 앞으로 이 장비를 도입하는 기관에 도움이 되고자 한다. 대상 및 방법: 모든 측정은 TrueBEAM STX (Varian, USA)를 이용하였으며, 전산화치료계획장비(Eclipse ver 10.0.39, Varian, USA)를 이용하여 각 에너지 별, 조사조건 별 선량분포파일을 산출하였다. MapCHECK 2의 고유의 성능과 오차로 발생 할 수 있는 원인에 대하여 측정 및 분석하였다. MapCHECK 2의 성능 확인을 위해 6X, 6X-FFF (Flattening Filter Free), 10X, 10X-FFF, 15X의 에너지별로 필드사이즈 $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ 방향에서 측정을 하였다. 또한 기존 IGRT couch의 CT값이 volumetric dosimetry에 영향을 주는지 확인을 위해서, CT 넘버 값: -800 (Carbon) & -950 (COUCH안의 공기), -100 & -950을 지정해준 상태에서 6X-FFF, 15X의 에너지별로 필드사이즈 $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ 방향에서 측정을 하였고, MapPHAN에 할당된 HU 값 확인을 위해 Solid water phantom 3 cm을 위로 얹은 MapCHECK 2와 치료계획용 컴퓨터를 이용해 비교하였고, MapPHAN의 각진 모서리에 의한 측정오류문제, MapPHAN의 gantry 방향 의존성을 알아보기 위해 3가지 방법으로 측정 하였다. 세로로 세운 세팅 상태에서 6X-FFF, 15X를 GANTRY $90^{\circ}$, $270^{\circ}$ 방향에서 각각 측정하고, 가로로 세운 세팅상태에서 에너지 6X-FFF, 15X를 필드사이즈 $10{\times}10$ cm, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$의 방향에서 각각 측정하였다. 세 번째로 빔의 세기조절을 하지 않은 상태에서 open arc를 조사하였다. 결 과: MapCHECK의 기본 성능을 확인, Couch에 의한 감약 측정, MAP-PHAN에 할당하는 HU값 측정, MapPHAN의 각진 모서리에 대한 계산 정확도 확인을 위한 측정에서 모두 유효한 범위에 들어와 측정오류에 영향을 미치지 않는 것을 확인 할 수 있었다. Gantry 방향의존성 확인하기 위한 3가지 방법 중 첫 번째로 측정기를 세운 상태에서의 값은 Gantry $270^{\circ}$ (상대적 $0^{\circ}$), $90^{\circ}$ (상대적 $180^{\circ}$)에서 6X-FFF, 15X에서 각각 -1.51, 0.83%와 -0.63, -0.22%를 나타내어 AP/PA 방향에 의한 영향이 없음을 나타냈다. 측정기를 가로로 세팅한 상태에서는 Gantry $90^{\circ}$, $270^{\circ}$에서 에너지 6X-FFF 4.37, 2.84%, 15X에서는 -9.63, -13.32%의 차이가 측정되어 gamma pass rate 3%의 값보다 큰 값을 나타내므로 MapPHAN에 의한 측방향 측정값이 유효범위 안에 들지 못하는 것을 확인 할 수 있었다. 마지막 Open Arc에서 6X-FFF, 15X 에너지를 필드사이즈 $10{\times}10$ cm에 $360^{\circ}$ 회전상태에서의 선량분포를 보면 pass rate가 90% 가까이 나오는 것을 확인 할 수 있다. 결 론: 위 결과를 토대로 MapPHAN은 상대등선량분포 감마값 측정에는 적합 하지만, 측방향 빔에 대한 gantry 방향의 의존성 때문에 절대선량은 정확한 측정을 할 수 없는 것으로 판단되어진다. 본 논문에서는 더욱 정확한 치료계획 확인을 위해서 VMAT 같은 회전조사시 측방향에 대한 오차를 줄이고 정확한 절대선량을 측정하기 위해서 MapCHEK 2와 IMF (Isocentric Mounting Fixture)의 조합을 사용하여 gantry 방향 의존성에 의한 영향을 최소화 할 수 있을 것이라 판단된다.

  • PDF