Zr-2.5Nb 중수로 압력관의 조사후 강도 및 파괴거동 특성 (The Strength and Fracture Behavior characteristics of Irradiated Zr-2.5Nb CANDU Pressure Tube Materials)

  • 안상복;김영석;김정규
    • 대한기계학회논문집A
    • /
    • 제25권3호
    • /
    • pp.510-519
    • /
    • 2001
  • The tensile and fracture toughness tests have been conducted to investigate the degradations of mechanical properties induced mainly by neutron irradiations in Zr-2.5Nb CANDU pressure tube materials operated in Wolsung Unit-1. the tests were performed at room, 150, 200, 250, 300 $\^{C}$ for the irradiated and unirradiated specimens in hot cell. The specimens were directly machined from the tube retaining original curvature using specially designed electric discharge machine(EDM). From the tensile tests of the irradiated specimens, it was found that tensile strength was increased and total elongation was decreased compared to those of the unirradiated ones. The active voltages in the fracture toughness tests for the irradiated showed the discontinuous abrupt increases caused by crack jumping in lower temperature. In the crack resistance curves we found the stable crack growth in the unirradiated, whereas the unstable and three crack growth stages in the irradiated specimens due to the accumulated irradiation defects. The various fracture characteristic values in the irradiated are remarkably lower than those of the unirradiated. Through the fractography, we found in the irradiated that smaller dimple and shorter fissures than the unirradiated, and that the fractured surface had three regions that were flat, transition and slant/shear area. These can explain the difference in the crack growth characteristic values of the irradiated and the unirradiated ones.

연속된 배관의 결함 검출을 위한 개폐식 와전류 탐촉자 개발 (Development of Open-Connect Type Eddy Current Transducers for the Detection of Surface Flaws in Continuous Pipeline)

  • 김영주;안봉영;이승석
    • 비파괴검사학회지
    • /
    • 제22권2호
    • /
    • pp.187-192
    • /
    • 2002
  • 서로 연결되어 있는 강관의 결함을 검사할 수 있도록 하기 위한 개폐식 탐촉자를 제작하였다. 본 탐촉자는 기존의 외삽형 와전류 탐촉자로서는 탐상이 불가능한 설치 가동중인 튜브류의 검사를 위한 것이다. 리본 케이블과 커넥터로 구성된 여기 코일은 접합/단락이 가능하게 하였으며 감지 코일은 튜브 외벽 근처에 원주 방향으로 어레이 형태로 배치하였는데 여기 코일로부터 튜브 직경의 약 1.5배정도 떨어진 위치이다. 제작된 탐촉자를 강관에 적용한 결과, 감도나 결함 크기 구분 등의 성능은 자기 포화형 탐촉자에 미치지 못하나 비교적 큰 결함의 발견이나 위치 파악 등에는 적용 가능한 것으로 나타났다. 크랙 형태의 표면 결함의 경우 두께의 19% 이상의 결함을 찾을 수 있었다.

연료극 지지체식 평관형 고체산화물 연료전지 특성 연구 (Characteristics of Anode-supported Flat Tubular Solid Oxide Fuel Cell)

  • 김종희;송락현
    • 전기화학회지
    • /
    • 제7권2호
    • /
    • pp.94-99
    • /
    • 2004
  • 연료극 지지체 평관형 고체산화물 연료전지(SOFC)의 셀 전력밀도를 증가시키기 위하여 압출법에 의하여 제조하고 그 특성을 연구하였다. 연료극 지지체로써 Ni/YSZ($8mol\%$ yttria stabilized zirconia) cermet는 기공율 $50.6\%,\;0.23{\mu}m$의 기공크기를 나타내었다. 지지체에서의 Ni의 분포는 균일하였으며 전자전도 경로로써의 Ni의 연결성은 양호하였다. 지지체에 YSZ전해질과 복합 공기극층인 $LSM((La_{0.85}Sr_{0.15})_{0.9}MnO_3)/YSZ$ 복합층, LSM, LSCF $(La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3)$층이 슬러리 디핑법에 의하여 코팅 및 소결된 연료극 지지체식 평관형 고체산화물 연료전지 단위전지의 성능은 $800^{\circ}C$에서 $300mW/cm^2(0.6V,\;500mA/cm^2)$의 성능을 나타내었다. 임피던스 분석에 의하여 평관형 셀의 전기화학적 분극저항을 평가하고 연료측의 가습에 따라 분극저항이 감소되어 성능이 향상됨을 알 수 있었다 슬러리 디핑법으로 LSM이 코팅된 SUS430 금속연결재를 $Ar+10\%\;H_2$에서 소결하였으며, $750^{\circ}C$에서 면저항의 측정할 결과, 초기에는 $148m{\Omega}cm^2$를 나타내었으며, 450시간 경과 후에 $43m{\Omega}cm^2$의 낮은 면저항을 유지하였다. 반면에 동일한 조건으로 LSM이 코팅된 Fecralloy는 높은 면저항을 나타내었다.

Characteristics of a new cone beam computed tomography

  • Park, Chang-Seo;Kim, Kee-Deog;Park, Hyok;Jeong, Ho-Gul;Lee, Sang-Chul
    • Imaging Science in Dentistry
    • /
    • 제37권4호
    • /
    • pp.205-209
    • /
    • 2007
  • Purpose: To determine the physical properties of a newly developed cone beam computed tomography (CBCT). Materials and Methods: We measured and compared the imaging properties for the indirect-type flat panel detector (FPD) of a new CBCT and the single detector array (SDA) of conventional helical CT (CHCT). Results: First, the modulation transfer function (MTF) of the CBCT were superior to those of the CHCT. Second, the noise power spectrum (NPS) of the CBCT were worse than those of the CHCT. Third, detective quantum efficiency (DQE) of the indirect-type CBCT were worse than those of the CHCT at lower spatial frequencies, but were better at higher spatial frequencies. Although the comparison of contrast-to-noise ratio (CNR) was estimated in the limited range of tube current, CNR of CBCT were worse than those of CHCT. Conclusion: This study shows that the indirect-type FPD system may be useful as a CBCT detector because of high resolution.

  • PDF

유한요소법에 의한 평면 TV 새도우마스크의 열변형해석 및 전자빔 오착 예측 (Thermal Deformation Analysis of Shadow Mask in a Flat TV and Prediction of Electron Beam Landing Shift by FEM)

  • 김정;박수길;강범수
    • 대한기계학회논문집A
    • /
    • 제26권11호
    • /
    • pp.2297-2304
    • /
    • 2002
  • Two-dimensional and three-dimensional finite element methods have been used to analyze the deformation behavior of a shadow mask due to thermal and tension load. The shadow mask inside the Braun tube of a TV set has numerous slits through which the electron beams are guided to land on the designed phosphor of red, green or blue. Its thermal deformation therefore causes landing shift of the electron beam and results in decolorization of a screen. For the realistic finite element analysis, the effective thermal conductivity and the effective elastic modulus arc calculated, and then the shadow mask is modeled as shell without slits. Next a transient thermal analysis of the shadow mask is performed, wherein thermal radiation is a major heat transfer mechanism. Analysis of the resulting thermal deformation is followed, from which the landing shift of the electron beam is obtained. The present finite element scheme may be efficiently used to reduce thermal deformation of a shadow mask and in developing prototypes of a large screen flat TV.

디지털 방사선 투과영상의 식별도 평가 연구 (The Study on Image Sensitivity Evaluation For Digital Radiography Image)

  • 박상기;이영호
    • 동력기계공학회지
    • /
    • 제12권6호
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study is to compare the quality of digital radiography image with that of classical film images for welded structure in power plants. The CMOS(Complementary Metal Oxide Semiconductor) flat panel detecter and Agfa D5 film are used to image flaw specimens respectively. In the test, CMOS flat panel detector has been determined to have a better image than that of film image. In the IQI(Image Quality Indicator) transmission test, one or two more line can be seen in digital image than in film image. Digital Radiography Test enabled to successfully detect all defects on the weld specimens fabricated with real reheat stem pipe and boiler tube as well. In the specific comparison test, Digital radiography test detected micro flaws in the size of 0.5 mm in length by 0.5 mm in depth. However, film test has limited it to 1.0 mm in length by 1.0 mm in depth. As a result of this study, digital radiography technology is estimated well enough to perform the inspection in the industry with far more cost effective way, compared to the classical film test.

  • PDF

평판형 태양열 집열기의 각도에 따른 집열성능 연구 (Study on the Heat Collecting Performance of Flat-Plate Solar Collector by the angle)

  • 지명국;공태우;배철환;정효민;정한식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.316-321
    • /
    • 2000
  • In this study, heat collecting performance was study of flat plate solar collector by the angle. A method of study on were made turn out artificial sun by the angle of 0, 15, 30 degrees. The heat performances were measured the tube array surface temperature by thermo-couple. The winter season natural condition for 4 times on the angles of various general and emboss glass at optimum distance(0.68m) calculated of between sun and solar collector. To sum up temperature rise is appear more or less that emboss glass is all the better for general glass. The temperature variable at below of 30 degree was appear very less. The maximum performance of this system at that it is tilt angle of 30 with general glass is appear Q:11.54(kcal/min) and ${\Delta}T=18.9^{\circ}C$.

  • PDF

Experimental Study on Heat Transfer Performance of Absorber with Variable Plate Types

  • M.A. Sarker;Moon, C.G.;Lee, H.S.;Kim, E.P.;Yoon, J.I.
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2004년도 춘계 학술발표회 논문집
    • /
    • pp.201-212
    • /
    • 2004
  • An experimental study of the absorption process of water vapor into a lithium bromide solution was performed. For the purpose of developing high performance absorption chiller/hater utilizing lithium bromide solution as working fluid, it is important to improve the performance of absorber with the larger heat transfer area of the four heat exchangers. The experimental apparatus was composed of a plate type absorber which could increase the heat exchange area per unit volume to investigate more detail characteristics instead of the conventional type, that is, horizontal tube bundle type. The size of plate absorbers were made for 0.4m$\times$0.6m and the design objective of a refrigeration capacity was 1RT. In this experiment, three kinds of plate absorbers namely flat plate, dimple plate and groove plate were used. The obtained results were less than the design objective values, that is, the refrigeration capacity was about 0.3 ~0.4RT and the overall heat transfer coefficient was 500~600 kcal/$m^2$h$^{\circ}C$ at the standard conditions.

  • PDF

두 종류 태양열 집열기를 이용하는 대규모 태양열 시스템의 동작특성 분석 (Analysis of Operating Characteristics of Large-scale Solar Thermal System Using Two Types of Collectors)

  • 이동원;허재혁;김민휘
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.67-75
    • /
    • 2017
  • We have investigated the operating characteristics of $1,600m^2$ large-scale solar thermal system installed in an eco-friendly energy town in Chungbuk Innovation City. The operation criteria of the collecting pump and storage pump were different from the existing standard, and it was confirmed that each pump works well according to the changed criteria. Based on the data of the representative day, the daily collecting heat (efficiency) and the production (storing) heat (efficiency) were estimated. It was confirmed that the daily collecting heat (efficiency) of the flat plate type was higher than that of the evacuated tube type, but the useful heat production was more in evacuated tube type collector.

냉장고 응축기의 전열성능에 대한 CFD 해석 (CFD ANALYSIS ON HEAT TRANSFER PERFORMANCE OF A REFRIGERATOR CONDENSER)

  • 유성수;황도연;이명수;한병윤;박형구
    • 한국전산유체공학회지
    • /
    • 제14권3호
    • /
    • pp.56-62
    • /
    • 2009
  • In this study, the heat transfer and flow field of a condenser used for a Kim-chi refrigerator is analysed with numerical method. Main objective is to present the basic data for designing a new condenser model with improvement of heat transfer performance. For CFD analysis, a commercial code, STAR CCM+ was used. The water was used for the inner working fluid and the air was used for the outer fluid. The condenser type used in this study is a flat plate fin-and-tube heat exchanger. As analysis parameters, the effect of condenser geometry and air velocity was investigated. For validation of the numerical calculations, the results were compared with the experimental ones. The heat transfer rates for both results were consistent with each other by maximum 5 % error. Based on this comparison, the numerical analysis was done with some modifications. As a result, it has been observed that there is a suitable fin pitch with which heat transfer performance of condenser is maximized.