• 제목/요약/키워드: Flat tubes

검색결과 82건 처리시간 0.019초

원형관 및 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 상관관계식 (Convective Heat Transfer Correlations for the Compact Heat Exchanger with Circular Tubes and Flat Tubes-Plate Fins)

  • 모정하
    • 대한기계학회논문집B
    • /
    • 제34권3호
    • /
    • pp.291-299
    • /
    • 2010
  • 본 연구에서는 열의 수가 세 개인 원형관 및 종횡비가 고려된 납작관-평판휜 형상의 밀집형 열교환기 내 공기의 유동 및 열전달 특성을 RNG $k-{\varepsilon}$ 난류모델을 적용하여 수치적으로 해석하였다. 수치조건의 범위는 원형관인 경우 1,000<$Re_D_h$<10,000이며, 납작관인 경우 1,000<$Re_{D_h}$<10,000 및 3.06$f\;=\;CRe^m_{D_h}$의 형태로, Colburn j 계수는 $j\;=\;CRe^m_{D_h}$ 형태로 상관관계식을 제시하였다. 이러한 상관관계식은 향후 원형관 및 납작관-평판휜 형상의 열교환기 설계시에 기본적인 자료로 충분히 활용될 수 있을 것으로 판단된다.

An Experimental Study on Laminar Heat Transfer in Flat Aluminum Extruded Tubes Having Small Hydraulic Diameter

  • Kim, Nae-Hyun;Ham, Jung-Ho;Kim, Do-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권2호
    • /
    • pp.47-53
    • /
    • 2007
  • Laminar heat transfer experiments were conducted in flat extruded aluminum tubes. Three different flat tubes-two with smooth inner channel, one with micro-finned inner channel-were tested. Smooth tube data were in reasonable agreement with the predictions by simplified theoretical models. The heat transfer coefficients of the micro-fin tube were significantly smaller than those of the smooth tube. The reason was attributed to the decelerating flow in the inter-fin region. Heat transfer correlations were developed from the data.

종횡비에 따른 납작관-평판휜 형상의 밀집형 열교환기 내공기 측 대류열전달특성에 대한 수치해석 (Numerical Analysis for the Air-Side Convective Heat Transfer Characteristics in a Compact Heat Exchanger with Flat Tubes and Plate Fins According to the Aspect Ratio)

  • 모정하
    • 대한기계학회논문집B
    • /
    • 제32권9호
    • /
    • pp.695-703
    • /
    • 2008
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in a compact heat exchanger with flat tubes and continuous plate fins according to the aspect ratio. RNG k-$\varepsilon$ model is applied for turbulence analysis. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous correlations for circular tubes. The numerical conditions are considered for the aspect ratios ranging from 3.06 to 5.44 and Reynolds number ranging from 1000 to 10,000. The results showed that heat transfer coefficients decreased with the increase of aspect ratio. From the calculated results a correlation of Colburn j factor for the considered aspect ratio in the compact heat exchanger system is suggested. The predicted results in this study can be applied to the optimal design of air conditioning system.

임의형상을 갖는 납작관에서의 혼합대류 열전달 해석 (Analysis of Mixed Convection Heat Transfer in Arbitrarily Shaped Flat Tubes)

  • 박희용;박경우;이상철
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.398-410
    • /
    • 2001
  • The flow and heat transfer characteristics for three-dimensional mixed convection flows in a radiator flat tube with U--shaped grooves are analyzed numerically. The flow and temperature fields are calculated by using the modified SIMPLE algorithm for irregular geometry. One tube specification among the various flat tube exchangers is recommended by considering the heat transfer and pressure drop. The effects of variation of coolant flow conditions and external air conditions on the flow and the thermal characteristics for the selected tube are investigated. the results show that inlet velocity of coolant flow is the very important factor in heat transfer and pressure drop, and top side is better position than the others as fin cleave to tube.

  • PDF

전열관의 마모 체적형상에 따른 마모깊이 예측 (Prediction of Wear Depth of SG Tube based on Types of Wear Scar)

  • 유기완;김형진;박치용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.475-478
    • /
    • 2005
  • Calculation of wear depth with regard to the wear topology is peformed numerically Four typical wear topology, that is round, crescent, flat, and diamond types are adopted to represent the configuration of wear volume. Diamond and flat types are the most severe topology for wear depth history, whereas round and crescent types have small increasing rate of wear depth to the wear volume. Based on this study we can guess that the most severe wear phenomena happens to be upper side of U-tubes in the KSNP SG, because flat or diamond wear will be generated by the wearing motion between tubes and diagonal, vertical, horizontal strips. The misalignment of tube at the stage of manufacturing or distortion of upper structure due to the thermal expansion or vibration of upper structure such as diagonal, vertical, and horizontal strips will be one of the main causes of flat or diamond wear.

  • PDF

CPM을 이용한 평판위 천이경계층에서 벽 마찰응력의 계측 (Measurement of Wall Shear Stress in Transitional Boundary Layer on a Flat Plate Using Computational Preston Tube Method)

  • 전우평;강신형
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.240-250
    • /
    • 1995
  • A CPM (computational preston tube method) was developed to measure wall shear stress in a transitional boundary layer on a flat plate using Preston tubes. Correlation for the displacement factor of Preston tubes was improved for a CPM to be used in the transitional boundary layer. The distribution of skin-friction coefficient was reasonably predicted in the uniform free stream of 3.1% turbulence intensity. Reasonable and accurate estimation of displacement factor of Preston tubes was found to be of crucial importance for the CPM, especially in the laminar boundary layer. The mean velocity profiles of the boundary layer on the plate were also measured and presented.

R-22 and R-410A Condensation in Flat Aluminum Multi-Channel Tubes

  • Kim, Nae-Hyun;Min, Chang-Keun;Jung, Ho-Jong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.114-124
    • /
    • 2003
  • In this study, condensation heat transfer tests were conducted in flat aluminum multi-channel tubes using R-410A, and the results are compared with those of R-22. The flat tubes have two internal geometries; one with smooth inner surface and the other with micro-fins. Data are presented for the following range of variables; vapor Quality (0.1∼0.9), mass flux (200∼600 kg/$m^2$s) and heat flux (5∼15 kW/$m^2$). Results show that the effect of surface tension drainage on the fin surface is more pronounced for R-22 than R-410A. The smaller Weber number of R-22 may be responsible. For the smooth tube, the heat transfer coefficient of R-410A is slightly larger than that of R-22. For the micro-fin tube, however, the trend is reversed. Possible reason is provided considering physical properties of the refrigerants. For the smooth tube, Webb's correlation predicts the data reasonably well. For the micro-fin tube, the Yang and Webb model was modified to correlate the present data. The modified model adequately predicts the data.

비대칭 엇갈림 배열로 구성된 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 특성 해석 (Analysis of Convective Heat Transfer Characteristics for the Compact Heat Exchanger with Flat Tubes and Plate Fins Having a Non-symmetric Staggered Arrangements)

  • 모정하;이상호
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.318-325
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchanger with flat tubes and continuous plate fins having a symmetric and non-symm etric staggered arrangements. Simulation results such as air velocity and temperature distributions are presented, and heat transfer coefficients are compared with previous experimental results. In order to investigate the flow and heat transfer features by periodic boundary conditions, the three blocks were used. Predicted heat transfer coefficients between the three blocks are similar while there are relatively differences, compared with the experimental data. From the calculated results a correlation for Colburn j factor in the compact heat exchanger system is suggested. The predicted results in this study can be applied to the optimal design of air conditioning system.

라디에이터용 납작관의 최적형상 도출을 위한 열.유동해석 (Flow and Thermal Analyses for the Optimal Specification of Flat Tube at Radiator)

  • 박경우;박희용
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1046-1055
    • /
    • 2000
  • The flow and thermal phenomena in flat tubes of radiator are analyzed numerically. To predict the characteristics of heat transfer and pressure drop, the flow analysis program for three-dimensional complex geometry is developed, which adopted an non-staggered grid system and Cartesian velocities as dependent variables of the momentum equations. Using the developed program, the effect of tube specifications on the heat transfer characteristics is investigated for various flat tubes. From this study, the following results are obtained; (1) For the same hydraulic diameter($D_h{\doteq}5.2$mm), the Nusselt numbers of three basic modeis(D, J, and H-model) are 8.71, 8.92, and 10.58, respectively, and the pressure drops of D-, J-, and H-model are predicted as $-3.08{\times}10^{-2}\;Pa,\;-3.12{\times}10^{-2}\;Pa,\;and\; -3.98{\times}10^{-2}$ Pa, (2) In case of the same flat tube specification, the fins must be brazed at upper tube surface because the heat is more vividly transferred. Therefore, it is found that the H- model is the most effective tube as a heat exchanger and these results are used as a fundamental data for the design of tube.