• Title/Summary/Keyword: Flat specimen

Search Result 158, Processing Time 0.025 seconds

A Fossil Feather from the Late Pleistocene Deposits in Jeiu Island, Korea (제주도 후기 플라이스토세 퇴적층에서 산출된 깃털 화석)

  • Kim, Jeong-Yul;Kim, Kyung-Soo;Kim, Sam-Hyang
    • Journal of the Korean earth science society
    • /
    • v.27 no.5
    • /
    • pp.579-584
    • /
    • 2006
  • A fossil feather found from the Late Pleistocene sediments of Jeju Island, Korea is described. The sediments deposited in a shallow marine environment yielded numerous footprints of diverse birds and mammals including hominids. A fossil feather well-preserved as a thin white film on the light gray mudstone is part of a vaned flight one. Although the specimen is relatively small in size (10.3 mm long and 9.0 mm wide), a rachis with two flat vanes and nearly parallel curved barbs with numerous proximal and distal barbules are well preserved. The specimen represents the first record of a fossil feather from Korea and is also the first record of feather from the Pleistocene deposits in the world.

Study on the Out-of-Plane Deformation Measurement Condition through Comparison Photosensitivity (광감도 비교를 통한 면외 변형 측정 조건에 대한 연구)

  • Kim, Hyun Ho;Kang, Chan Geun;Lee, Hyun Jun;Jung, Hyun Chul;Kim, Kyeong Suk;Hong, Chung Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.9
    • /
    • pp.807-813
    • /
    • 2015
  • In the present study, an interferometer system, which integrates the laser sensitivity control technique based on the theory of electronic speckle pattern interferometry, one of non-contact non-destructive analysis methods, was developed. This interferometry system receives an image from CCD cameras for each reference and object, and compares the photosensitivity of the object and reference images from imagification. For the purpose of this study, the photosensitivity of object and reference light is measured with power meters, and the amount of light was controlled with an ND filter with a reference light port matching photosensitivity. Using the plate specimen as the object, 0.6, 0.9, 1.2, and $1.5{\mu}m$ of out-plane deformation was made, and images were compared according to the difference in photosensitivity. After analysis, larger object deformations showed larger numbers of stripe patterns. Images became clearer and data error was reduced when the photosensitivity of object and reference light matched.

Development of Radiometric Scanning System for the Evaluation of the Pipeline (배관 검사용 Radiometric Scanning System 제작 및 시험)

  • Kim, Yong-Kyun;Hong, Seok-Boong;Chung, Chong-Eun;Lee, Yoon-Ho;Jung, Yong-Ha;Lee, Jeong-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.474-482
    • /
    • 2002
  • One dimensional Radiometric scanning system was fabricated and tested as a filmless radiographic inspection system, which could be applied to the evaluation of the corrosion and deposits in the pipeline. This system is composed of the single radioactive source of the collimated focusing beam, and single scintillation detector of BGO, and the mechanical scanning system to transport and align the source and detector, and the operating software to automatically control the mechanical scan system. The performance of the system was simulated using GEANT4 software. This system is applied to one specimen having an artificial falw(flat bottom hole) in the pipe and the other specimen with thickness variation. For the inspection by using the radioactive source in the pipeline, it is possible to evaluate the corrosion and deposits in real time and without film.

Measurement of Residual Stress Using Photoelasticity and Computer Simulation of Optical Characteristics in a Transparent Injection Molded Article (광탄성을 이용한 투명한 사출성형품의 잔류응력측정 및 광학적 특성의 컴퓨터 모사)

  • Hong, Jin-Soo;Park, Seo-Ri;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.35 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Pressurized high temperature plastic resin flows into the cavity of mold and is solidified in injection molding process. Residual stress is being developed in injection molded part because of high temperature variations and high pressure. Developed residual stress relaxes as time goes. Consequently this makes part deformed and deteriorates quality of product. A measurement method of residual stress for injection molded transparent articles has been investigated using photoelasticity. Light, a composite of electromagnetic waves, is purified into a single wave by a polarized film. When this wave passes through the specimen, birefringence is developed according to the level of residual stress in the specimen and color fringed pattern appears after the second polarized film. Residual stress in the injection molded transparent flat a part has been measured quantitatively using the color fringed pattern. Optical characteristics have been a part also predicted by computer simulation and compared with experimental results.

REWETTING EFFECT OF WATER-BASED PRIMER ON THE AIR-DRIED DENTIN (공기건조된 상아질에 대한 수분함유 primer의 재습윤효과)

  • Kim, Ki-Young;Park, Jeong-Kil;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.498-503
    • /
    • 2003
  • The purpose of this study was to evaluate the rewetting effect of water-based primer on the air-dried dentin. In this in vitro study, freshly extracted non-caries human molars and three-step adhesive system(SBMP) were used. Freshly extracted non-caries human molars and three-step adhesive system(SBMP) were used. Flat occlusal dentin surface were prepared using low-speed diamond saw, Prepared teeth were randomly divided into three groups. Group 1.(W): etched(35% phosphoric acid for 15s) and blot-dried, Group 2.(5D): 5s air-dried, Group 3.(30D): 30s ail-dried, To obtain color contrast in CLSM observation, primer was mixed with rhodamine B and bonding resin was mixed with fluorescein. Microscopic sample of each group were obtained after longitudinal section. Morphological investigation of resin-dentin interface and thickness of hybrid layer measurement using CLSM were done. Microtensile bond strength for each specimen was measured. Specimen were observed under microscope to examine the failure patterns of interface between resin and dentin. The results of this study were as follows: 1. The results(mean) of Thickness of hybrid layer were W:19.67, 5D:20.9, 30D:10$\mu\textrm{m}$. Only 30D had statistically significant differences to Wand 5D(P<0.05). 2. The results(mean) of Microtensile bond strength were W:16.02, 5D:14.69, 30D:11.14MPa. Only 30D had statistically significant differences to Wand 5D(P<0.05). 3. There were positive correlation between Thickness of hybrid layer and microtensile bond strength(P<0.05).

Comparison of Coffee Stain Removal Effects of Commercial Whitening Toothpaste in Sound and Demineralized Teeth In Vitro

  • Ji-Hyun Min
    • Journal of dental hygiene science
    • /
    • v.23 no.3
    • /
    • pp.236-244
    • /
    • 2023
  • Background: The size of the tooth whitening market and toothpaste market is increasing worldwide. The purpose of this in vitro study is to confirm and compare the coffee stain removal effects of commercial whitening toothpaste in sound and demineralized teeth, respectively. Methods: A total of 112 flat permanent bovine teeth specimens were manufactured. Half of the surface of the specimen was coated with an acid-resistant varnish and deposited in an artificial demineralizing solution for 65 hours. The varnish applied to half of the specimen was removed and deposited in a coffee solution for 96 hours to induce coloring. Two control and five experimental group toothpastes for teeth whitening were selected and the main components were investigated. Toothbrushing was performed 50, 100, and 150 times for each toothpaste group. A total of four images were obtained: before the start and after 50, 100, and 150 times of brushing to obtain the lightness (L*) values of the sound and the demineralized tooth surfaces. The difference in the average value between toothpaste groups at each treatment period was analyzed by one-way ANOVA. The difference in the L* average value according to the number of the brushing was analyzed by repeated measure ANOVA. Results: All toothpastes in the seven groups contained abrasive agents and had different ingredients for each product. Compared to before brushing, the L* value changed significantly in all toothpaste groups after brushing 50 times (p<0.05). This was common in both the sound and demineralized teeth surfaces. Demineralized teeth had significantly lower L* values at all brushing times than that in sound teeth (p<0.05). Conclusion: The effect of whitening teeth was different for each toothpaste. Demineralized teeth were more likely to cause coloration than sound teeth, and the coloration was not removed well.

Natural History of Early Gastric Cancer: a Case Report and Literature Review

  • Iwai, Tomohiro;Yoshida, Masao;Ono, Hiroyuki;Kakushima, Naomi;Takizawa, Kohei;Tanaka, Masaki;Kawata, Noboru;Ito, Sayo;Imai, Kenichiro;Hotta, Kinichi;Ishiwatari, Hirotoshi;Matsubayashi, Hiroyuki
    • Journal of Gastric Cancer
    • /
    • v.17 no.1
    • /
    • pp.88-92
    • /
    • 2017
  • Early detection and treatment decrease the mortality rate associated with gastric cancer (GC). However, the natural history of GC remains unclear. An 85-year-old woman was referred to our hospital for evaluation of a gastric tumor. Esophagogastroduodenoscopy identified a 6 mm, flat-elevated lesion at the lesser curvature of the antrum. A biopsy specimen showed a well-differentiated tubular adenocarcinoma. The depth of the lesion was estimated to be intramucosal. Although the lesion met the indications for endoscopic resection, periodic endoscopic follow-up was performed due to the patient's advanced age and comorbidities. The mucosal GC invaded into the submucosa 3 years later, and finally progressed to advanced cancer 5 years after the initial examination. The patient died of tumor hemorrhage 6.4 years after the initial examination. In this case, mucosal GC progressed to advanced GC, eventually leading to the patient's death from GC. Early and appropriate treatment is required to prevent GC-related death.

Epicuticular Waxes and Stomata of Adult Scale Leaves of the Chinese Juniper Juniperus chinensis

  • Kim, Ki-Woo
    • Applied Microscopy
    • /
    • v.42 no.3
    • /
    • pp.124-128
    • /
    • 2012
  • Leaf surface structures were investigated in the Chinese juniper Juniperus chinensis by scanning electron microscopy. Adult scale leaves were collected from the tree, air-dried at room temperature, and sputter-coated with gold without further specimen preparation. Approximately fi ve stomata were locally distributed and arranged in clusters on the leaf surface. Stomata were ovoid and ca. 40 ${\mu}m$ long. The epicuticular wax structures of J. chinensis leaves were tubules and platelets. Numerous tubules were evident on the leaf regions where stomata were found. The tubules were cylindrical, straight, and ca. 1 ${\mu}m$ in length. They almost clothed the stomatal guard cells, and occluded the slit-shaped stomatal apertures. Moreover, the wax ridges were flat crystalloids that were connected to the surface by their narrow side. They did not have distinct edges, and their width/height ratio varied. In particular, the wax ridges could be discerned on the leaf regions where stomata were not present nearby. Since the wax ridges did not have distinct edges on their margin, they were identified as platelets. Instances were noted where platelets were oriented either parallel to each other or perpendicular to the cuticle surface. These results can be used in biomimetics to design the hierarchical structures for mimicking the plant innate properties such as hydrophobicity and self-cleaning effects of the leaf surface.

Effusion Cytology of Squamous Cell Carcinoma (전이성 편평 세포암종의 체액 세포학적 소견)

  • Myong, Na-Hye;Ko, Jae-Soo;Ha, Chang-Won;Cho, Kyung-Ja;Jang, Ja-June
    • The Korean Journal of Cytopathology
    • /
    • v.3 no.1
    • /
    • pp.12-18
    • /
    • 1992
  • It is very rare to diagnose a squamous cell carcinoma when the carcinoma cells are observed in various body fluids. The effusion cytology of squamous cell carcinoma has not been sufficiently studied till now. We examined 10 cases of body fluid cytologic specimen diagnosed as metastatic squamous ceil carcinoma, which were selected among 2,100 body fluid cytology cases collected from 1986 to 1991. The patients had been confirmed to have primary squamous ceil carcinomas. The backgrounds of cellular aspirates were necrotic in most and the cells appeared in clusters or individually. The cell clusters showed round and smooth margins, mimicking adenocarcinoma, but in flat sheets rather than three-dimensional bails. the individual cells were most frequently Graham's 3rd-type cells, found in all cases, which were described as 1.5 times large as the parabasal cells and having small cytoplasmic rims. Other malignant squamous cells were undifferentiated cells, polygonal cells, fiber cells, and tadpole cells with decreasing order of frequency. The recognition of various features of malignant squamous cells would be helpful for the diagnosis of squamous ceil carcinoma found in effusion cytology.

  • PDF

Effect of Contact Area on Friction and Wear Behavior in Atomic Force Microscope (원자 현미경을 이용한 접촉 면적에 따른 마찰 및 마멸 특성 분석)

  • Choi Dukhyun;Hwang Woonbong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.167-173
    • /
    • 2004
  • Recently, it has been reported that frictional behavior at nanometer scale can be different from that at macro scale. In this article, friction and wear tests were conducted using an AFM to investigate the effect of real contact area on the coefficient of friction and wear property. SiO$_2$, Hica, and SiGe were used in friction test and the AFM tip was Si$_3$N$_4$. The real contact area between an AFM tip and flat surface was calculated by the Johnson-Kendall-Roberts (JKR) theory. Wear specimen was Mica, and the diamond tip was used. We found that the coefficient of friction is constant below a critical area, but it is degraded over the area. Moreover, it is found that wear depth increased rapidly from a certain load and was degraded as a function of the number of the scanning cycles. Also, the range of scanning velocity used in this study had little effect on the wear depth.