• Title/Summary/Keyword: Flat Nozzle

Search Result 140, Processing Time 0.019 seconds

A Study of Spray Characteristics for the Shape of Nozzle by Phase Doppler Analyzer (PDPA를 이용한 노즐의 형상에 따른 분무 특성의 연구)

  • Hwang, S. S.;Lee, H. S.;Kim, J.;Lee, B. G.;Kim, J. C.;Chun, U. H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.199-210
    • /
    • 1998
  • The skill that utilizes atomization of the liquid has been widely used in the field of industry and engineering. Though there are dozens of methods to make atomization, the pressure type injection nozzle is frequently used in washing of parts, pastourization and painting because it has relatively simple system. This study is to reveal the characteristics of atomizing formed by three different types of the pressure type injection nozzle. We measured velocity and diameter of droplet to compare and analyze characteristic of each nozzle. In case of velocity, atomization of hollow-cone nozzle is irregular than others and change of radial direction is especially large. Atomization of flat nozzle is nearly uniform. In case of diameter, atomization of hollow-cone nozzle is increased rapidly, as measurement point become more distant from the center of nozzle. Atomization of flat nozzle has the most fixed magnitude. Accordingly, full-cone nozzle can be used irrespective of the form of subject and hollow-cone nozzle is proper to the occasion to spray large and smooth subject. Also, flat nozzle is proper to the occasion to spray a part of subject and long groove.

  • PDF

Design Factors of Boom Sprayer(II) -Spray Droplet Size and Coverage Characteristics on Rice Plants- (붐방제기 살포장치의 설계요인 구명을 위한 실험적 연구(II) -노즐의 분무유형 및 벼의 피복특성-)

  • 정창주;김학진;이중용;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.313-322
    • /
    • 1995
  • This study was conducted to find the design factors of spraying device of the boom sprayer for low volume application. Specific objectives of this study were 1) to select proper nozzles for broadcast spraying and row crop spraying by the nozzle spray characterisic experiment, and 2) to investigate the coverage characteristic of rice plant at the row crop spraying. The results of this study are summarized as follows. (1) From the tested results on the droplet diameter spectrum and spray pattern the standard flat-fan nozzle and drift guard nozzle were judged as appropriate for the broadcasting. Even flat-fan nozzle showed similar span values to standard flat-fan nozzles and drift guard nozzle : however, the nozzles were found to be inappropriate for broadcasting because of their spray pattern. Hollow cone nozzle showed relatively small span values and uniform spray pattern. (2) For the upper and lower sides of the rice plants, coverage rates of even flat-fan nozzles and hollow cone nozzles were maximum at the second row, but decreased rapidly after the third row. For the middle side of the rice plants, coverage rates of them were maximum at the first row, but decreased rapidly. When one nozzle was tested, C.V. values were in the range of 90~160% and 60~160% on entire heights of rice plant for even flat-fan nozzles and hollow cone nozzles respectively. C.V. values at other parts were poor. Spray coverage rate at the middle part was improved by overlapping the nozzles whereas there was little difference on the upper and lower part of rice plants. (3) For spraying lower part of rice plant between rows, even flat-fan nozzles and hollow cone nozzle were judged as appropriate, but in order to ensure the uniform coverage, distance between nozzles, recommended to be less than 90cm.

  • PDF

A study on the local heat transfer in rectangular impinging water jet cooling system (장방형 충돌수분류 냉각계의 국소열전달에 관한 연구)

  • Lee, Jong-Su;Eom, Gi-Chan;Choe, Guk-Gwang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1395-1405
    • /
    • 1996
  • The purpose of this experimental research is to investigate the local heat transfer characteristics in the upward free water jet impinged on a downward flat plate of uniform heat flux. The inner shape of rectangular nozzle used was sine curve type and its contraction ratio of inlet to outlet area was five. Experimental parameters considered were Reynolds number, nozzle exit-flat plate distance, and level of supplementary water. Local Nusselt number was influenced by Reynolds number, Prandtl number, supplementary water level, and distance between the nozzle exit and flat plate. Within the impingement region, the Nusselt number has a maximum value on the nozzle center axis and decreases monotonically outward from center. Outside of the impingement region, on the other hand, the Nusselt number has a secondary peak near the position where the distance from nozzle center reaches four times the nozzle width. However if nozzle exit velocity exceeds 6.2 m/s, the secondary peak appears also in the impingement region. The empirical equation for the stagnation heat transfer is a function of Prandtl, Reynolds, and axial distance from the nozzle exit. The optimum level of supplementary water to augment the heat transfer rate at stagnation point was found to be twice the nozzle width.

An Experimental Study on the Characteristics of Rectangular Supersonic Jet on a Flat Plate

  • Kwak, Ji-Young;Lee, Yeol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.324-331
    • /
    • 2016
  • The present study focuses on the characteristics of a supersonic jet flowing from a rectangular nozzle exit on a flat plate. Flow visualization techniques using schlieren and kerosene-lampblack tracing are utilized to investigate shock reflection structures and boundary-layer separations over a flat plate. Wall pressure measurements are also carried out to quantitatively analyze the flow structures. All observations are repeated for multiple jet flow boundary conditions by varying the flap length and nozzle pressure ratio. The experimental results show that the jet flow structures over the flat plate are highly three-dimensional with strong bleeding flows from the plate sides, and that they are sensitive to plate length and nozzle pressure ratio. A multi-component force measurement device is also utilized to observe the characteristics of the jet flow thrust vectoring over the plate. The maximum thrust deflection angle of the jet is about $8^{\circ}$, demonstrating the applicability of thrust vector control via a flat plate installed at the nozzle exit.

An Experimental Study of Underexpanded Moist Air Jet Impinging on a Flat Plate

  • Lee, D.W.;S.C. Baek;S.B. Kwon;Kim, H.D.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.768-773
    • /
    • 2004
  • When a gas expands through a convergent nozzle in which the ratio of the ambient to the stagnation pressures is higher than that of the critical one, the issuing jet from the nozzle is underexpanded. If a flat plate is placed normal to the jet at a certain distance from the nozzle, a detached shock wave is formed at a region between the nozzle exit and the plate. In general, supersonic moist air jet technologies with nonequilibrium condensation are very often applied to industrial manufacturing processes. In spite of the importance in major characteristics of the supersonic moist air jets impinging to a solid body, its qualitative characteristics can not even know. In the present study, the effect of the nonequilibrium condensation on the underexpanded moist air jet impinging on a vertical flat plate is investigated experimentally. Flow visualization and impact pressure measurement are performed for various relative humidities and flat plate positions. The obtained results show the plate shock and Mach disk are dependent on the nozzle pressure ratio and the relative humidity, but for a given nozzle pressure ratio, the diameters of the plate shock and Mach disk depend on the stagnation relative humidity. The impact pressure deviation from the flow of without condensation is large, as the relative stagnation humidity increases.

  • PDF

An Experimental Study on Heat Transfer and Flow Characteristics of a Circular Impinging Jet on a Flat Plate : Effects of Nozzle Wall Thickness and Nozzle Exit Pressure (원형 제트 충돌 열전달과 유동 특성에 관한 실험적 연구 : 노즐 벽 두께와 노즐 출구 압력의 영향)

  • Yoon, Sangheon;Yang, Geunyoung;Sohn, Dong Kee;Choi, Mansoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1285-1295
    • /
    • 1999
  • An experimental study on heat transfer and flow characteristics of a circular impinging jet on a flat plate has been carried out. Of particular interests are the effects of nozzle wall thickness and nozzle exit pressure. Experimental apparatus has been designed to view heating plate coated by TLC from the opposite side of the nozzle in order to measure heat transfer rates for cases of very small nozzle to plate spacings. A visualization study of jet flows has also been performed. As the nozzle wall thickness increases at small nozzle to plate spacings, the effect of mixing is inhibited due to the confinement caused by the finite nozzle wall, consequently, heat transfer rates have been decreased. At small nozzle to plate spacings, heat transfer rates and nozzle exit pressures are increased together, therefore, enhancement of heat transfer at small nozzle to plate spacings should be considered in conjunction with the need of more fan power to generate the same Reynolds numbers.

Design Factors of Boom Sprayer(I) - Spray Patterns of Nozzles - (붐방제기 살포장치의 설계요인 구명을 위한 실험적 연구(I) -노즐의 분무유형-)

  • 정창주;김학진;조성인;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • v.20 no.3
    • /
    • pp.217-225
    • /
    • 1995
  • This study was conducted to find design factors of spraying device of the boom sprayer for low volume application. Four types of nozzles(standard flat nozzle, drift guard nozzle, even flat nozzle, and hollow cone nozzle) were used for the spray characteristic experiment. Spray patterns of the nozzles were distinguished by the nozzle type, spray distance, and spray direction. The flow rate was proportional to the square root of spray pressure in all nozzles. Increased nozzle height improved spray distribution at reduced pressures and/or increased spacing. Distribution tended to improve as pressure increased within the range of pressures used for fan nozzles.

  • PDF

Control of Bead Geometry and Effect of Protection against Wind according to the CDP Gas Nozzle in Arc Welding (Arc용접에서 CDP Gas Nozzle에 의한 비드형상제어 및 방풍효과)

  • Seo, Ji-Seok;Ham, Hyo-Sik;Im, Sung-Bin;Ha, Jong-Moon;Son, Chang-Hee;Cho, Sang-Myung
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.25-25
    • /
    • 2009
  • 종래의 위보기 자세에서 용접은 중력이 모재의 표면으로 향하고 있어 용융금속이 중력에 의해 표면방향으로 흘러내리게 되어 용접 실시가 불가능하였다. 이에 Shield Gas Force, Trailing Gas Force 그리고 Ahead Gas Force를 적절히 적용하여 Position Welding에서 중력으로 인해 Molten Metal이 처지는 문제를 극복하여 생산성 향상으로 연결할 수 있음을 선행 실험을 통해 확인하였으나 기존의 C(Convergent)형, CP(Convergent Divergent)형 및 P(Parrallel)형 가스 노즐은 용접조건에 따라 실드 가스의 소모량이 많고, 토출되는 실드가스력이 부족하여 용접시 볼록한 이면 비드 형성을 위한 용융 풀을 효과적으로 제어 할 수 없다. 따라서 본 연구에서는 동일량의 실드 가스 공급시 가스 노즐을 통해 토출되는 실드가스의 소모를 줄이고 실드가스력을 극대화하여 저가의 고생산성을 가진 친 환경 용접기술(Green welding)에 부합하는 CDP(Convergent Divergent Parrallel)형 가스 노즐을 제작하여 기존의 CP형 가스 노즐과 비교 분석하였다. 또한 Overhead Position에서의 비드형상제어와 Flat Position에서 방풍효과를 비교해 보았다. 그 결과 CDP Nozzle은 CP Nozzle보다 동일한 유량에서 풍속은 3.5배, 냉각능력은 1.5배, 가스압력은 6.25배로 우수한 성능을 확인할 수 있었고, Overhead Position에서 가스 유량을 동일하게 하여 용접하였을 때 CP Nozzle의 경우 오목한 이면비드가 나타났지만 CDP Nozzle의 경우 볼록하게 양호한 이면비드 형상이 나타났고, Flat Position에서의 방풍효과 비교실험에서 CDP Nozzle에서는 깊고 균일한 용입을 CP Nozzle에서는 불안정한 용입이 나타났는데 이는 CDP Nozzle의 경우 풍속에 의한 Arc Blow가 적게 발생하여 상대적으로 더 나은 용입을 확인하였다.

  • PDF

Characteristics of Supersonic Jet Impingement on a Flat Plate

  • 홍승규;이광섭;박승오
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.134-143
    • /
    • 2001
  • Viscous solutions of supersonic jet impinging on a flat plate normal to the flow are simulated using three-dimensional Navier-Stokes solver. The jet impinging flow structure exhibits such complex nature as shock shell, plate shock and Mach disk depending on the flow parameters. Among others, the dominant parameters are the ratio of the nozzle exit pressure to the ambient pressure and the distance between the nozzle exit plane and the impinging plane. In the present study, the nozzle contour and the pressure ratio are held fixed, while the jet impinging distance is varied to illuminate the characteristics of the jet plume with the distance. As the plate is placed close to the nozzle at 3D high, the computed wall pressure at or near the jet center oscillates with large amplitude with respect to the mean value. Here D is the nozzle exit diameter. The amplitude of wall pressure fluctuations subsides as the distance increases, but the maximum pressure level at the plate is achieved when the distance is about 4D high. The frequency of the wall pressure is estimated at 6.0 kHz, 9.3 kHz, and 10.0 kHz as the impinging distance varies from 3D, 4D, to 6D, respectively.

  • PDF

A Study on the Spray Cooling Characteristics of hot Flat Plates (고온평판의 분무냉각특성에 관한 연구)

  • 윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.880-887
    • /
    • 1998
  • In order to study heat transfer characteristics of spray cooling for the purpose of uniform and soft cooling of high temperature surface a series of experiments for a hot horizontal copper flat plate was performed by downflow spray water using flat spray nozzle. Cooling curves were mea-sured under the various experimental conditions of flow rates and temperatures of cooling water Surface temperature surface heat fluxes and heat transfer coefficients of horizontal upward-facing flat surface were calculated with cooling curves measured at each radial positions near the cooling surface by TDMA method. Generally heat transfer characteristics for spray cooling is simi-lar to boiling phenomenon of pool boiling. The minimum heat flux(MHF) appear at the surface temperature of about ${\Delta}Tsat=250^{\circ}C$ and the critical heat flux(CHF) appear at about ${\Delta}Tsat=250^{\circ}C$.

  • PDF