• Title/Summary/Keyword: Flat Foot

검색결과 131건 처리시간 0.023초

보행 시 Wedged 인솔과 보행진행 각이 슬관절 외측 밀림(Lateral Thrust)에 미치는 영향 (The Influence of Wedged Insole and Foot Progression Angle on Lateral Thrust of Knee During Walking)

  • 정도영;김문환;권오윤
    • 한국전문물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.27-34
    • /
    • 2004
  • The purpose of this study was to identify the influence of wedged insole and foot progression angle (FPG) on lateral thrust of knee in healthy subjects. Fifteen healthy male subjects were recruited from Suncheon First College, in Suncheon. The subjects randomly walked at the comfortable velocity under five conditions: bare footed, medio-lateral $10^{\circ}$ wedged insoles, toe-in and toe-out gait. The lateral thrust was measured by a accelerometer with telemeter during walking. Data was collected while each subject walked for about 10 gait cycle on a flat, level walkway at their normal speed. The middle three gait cycle were used for averaged peak value of lateral acceleration. The three averaged peak value of lateral acceleration were collected under each condition at heel strike. The results showed that averaged peak value of lateral acceleration increased significantly in medial wedged insole and toe-in gait and decreased significantly in lateral wedged insole and toe-out gait as compared with bare footed (p<.05). These results suggest that wedged insole as well as walking strategy, such as foot progression angle, may prevent progression of degenerative knee osteoarthritis.

  • PDF

운동 선수군의 제 5중족골 피로골절의 수술적 치료 후 발생한 재골절 (Refracture of Proximal 5th Metatarsal Stress Fracture in Athletes Treated Operatively)

  • 이경태;양기원;김재영;방유선;이상준
    • 대한족부족관절학회지
    • /
    • 제7권1호
    • /
    • pp.95-100
    • /
    • 2003
  • Purpose: To evaluate the incidence, contributing factors, and clinical results of refracture of proximal 5th metatarsal stress fracture treated operatively in athletes Materials and Methods: This study included 8 patients who had been treated for refracture of proximal 5th metatarsal stress fracture with operaton. Their charts & radiologic findings were evaluated retrospectively. Results: The overall incidence of refracture was 13%. Main contributing factors were time of return to sports activity and associated deformities such as cavus foot or flat foot. Seven cases were managed with nonoperative treatment, and we added percutaneous pin fixation under local anesthesia in one case. Bony union was seen at average 8. 5 weeks in 7 cases except 1 nonunion and all of 8 patient returned to athletics at average 16 weeks. Conclusion: The incidence of refracture of proximal 5th metatarsal stress fracture treated operatively in athletes was relatively high. Time of rerum to sports activity must be decided very carefully on individual situation and further imaging study may be helpful for bony union evaluation. The non-operative treatment may have a good result if bone graft was done initially.

  • PDF

화상을 동반한 당뇨발 환자에게 Razor Blade를 이용한 부분층피부조각 이식술의 효용성 (Fragmented Split-Thickness Skin Graft Using a Razor Blade in Burn Induced Diabetic Foot)

  • 박철흠;최만기;강찬수;김태곤
    • 대한화상학회지
    • /
    • 제23권1호
    • /
    • pp.20-24
    • /
    • 2020
  • Diabetic patients have an increased risk of burn injuries on foot. Because of their diabetic neuropathy, they could contact with hot water or warming device without being aware of it. Split-thickness skin graft (STSG) is successful in treatment of various wound types; however, donor site wounds are sometimes problematic, and complications such as pain and impaired healing often occur. Although, donor site wounds in healthy young individuals can rapidly heal without complications, the wound-healing capacity of elderly patients or those with a comorbidity has been reported to be low. The dermatome is the most commonly used tool because it can harvest a large skin graft in one attempt. However, it is difficult to harvest tissues if the area is not flat. Furthermore, because the harvested skin is usually rectangular, additional skin usually remains after skin grafting. Therefore, use of razor blade and fragmented STSG on a large defect area is advantageous for harvesting a graft with a desired size, shape, and thickness. From January 2018 to July 2018, fragmented STSG was used in 9 patients who suffered from burn induced open wound on foot with diabetic neuropathy. With this approach, healing process was relatively rapid. The mean age of patients was 70 (57~86 years) and all of 9 patients had diabetes mellitus type 2. In all patients, the skin graft on the defect site healed well and did not result in complications such as hematoma or seroma.

두 족저압 측정장비의 비교 분석 (Comparative Analysis of Two Pedobarography Systems)

  • 강호원;변수민;김대유;조윤재;경민규;이동연
    • 대한족부족관절학회지
    • /
    • 제28권1호
    • /
    • pp.21-26
    • /
    • 2024
  • Purpose: Foot pressure measurement devices are used widely in clinical settings for plantar pressure assessments. Despite the availability of various devices, studies evaluating the inter-device reliability are limited. This study compared plantar pressure measurements obtained from HR Mat (Tekscan Inc.) and EMED-n50 (Novel GmbH). Materials and Methods: The study involved 38 healthy male volunteers. The participants were categorized into two groups based on the Meary's angle in standing foot lateral radiographs: those with normal feet (angles ranging from -4° to 4°) and those with mild flatfeet (angles from -8° to -15°). The static and dynamic plantar pressures of the participants were measured using HR Mat and EMED-n50. The reliability of the contact area and mean force was assessed using the interclass correlation coefficient (ICC). Furthermore, the differences in measurements between the two devices were examined, considering the presence of mild flatfoot. Results: The ICC values for the contact area and mean force ranged from 0.703 to 0.947, indicating good-to-excellent reliability across all areas. EMED-n50 tended to record higher contact areas than HR Mat. The mean force was significantly higher in the forefoot region when measured with EMED-n50, whereas, in the hindfoot region, this difference was observed only during static measurements with HR Mat. Participants with mild flatfeet exhibited significantly higher contact areas in the midfoot region for both devices, with no consistent differences in the other parameters. Conclusion: The contact area and mean force measurements of the HR Mat and EMED-n50 showed high reliability. On the other hand, EMED-n50 tended to record higher contact areas than HR Mat. In cases of mild flatfoot, an increase in contact area within the midfoot region was observed, but no consistent impact on the differences between the two devices was evident.

광주, 전남지역 대학생의 신발착용 실태에 관한 연구 (A Study on Actual Footwear-wearing Conditions of College Students in Kwangju & Jeonam)

  • 정영옥
    • 한국지역사회생활과학회지
    • /
    • 제22권3호
    • /
    • pp.365-377
    • /
    • 2011
  • The dual purposes of this study were to investigate footwear worn by college students who have become spoilt for choice in apparel & shoes, and point out the problems of their shoe-wearing habbits. The survey was administered in October, 2010 to 600 college residents in Kwangju-Jeonnam area and the results are as follows. Firstly, the most frequently worn footware by males were sneakers, followed by dress shoes and oxford shoes. Females followed a similar trend with sneakers being the most frequently worn, followed by high heeled shoes, flat shoes, wedge high heeled shoes and chucker boots. Secondly, both male and female students thought that the most comfortable and favorable shoes for them were sneakers and the most uncomfortable ones were high-heeled shoes and sandals. They thought chucker boots were both fashionable and comfortable. Thirdly, the degree of unsatisfaction for shoes was relatively high and the influencing factors for unsatisfaction were uncomfortable soles, aches around the toes and a frontward leaning posture of the body, etc. Finally, 87% of the female subjects who had experience wearing high-heeled(over 7cm height) shoes showed a significant increase in foot disorders than those who had never worn high-heeled shoes. According to the results, it is necessary to educate proper selection and wearing of footwear in order to prevent foot disorders and maintain overall health of the body.

스마트 인솔의 족저압 측정 결과에 대한 타당도 및 신뢰도 평가 (Assessment of Validity and Reliability of Plantar Pressure in Smart Insole)

  • 강호원;안예린;김대유;이동오;박길영;이동연
    • 대한족부족관절학회지
    • /
    • 제26권3호
    • /
    • pp.130-135
    • /
    • 2022
  • Purpose: Smart insoles are wearable devices that are inserted into shoes. Smart insoles with built-in pressure and acceleration sensors can measure the plantar pressure, stride length, and walking speed. This study evaluated the validity and reliability of the plantar pressure measurements of smart insoles during walking on flat ground. Materials and Methods: Twenty one subjects were included in this study. After wearing smart insoles, I-SOL® (Gilon, Seongnam, Korea), the subjects walked a 10 m corridor six times at a rate of 100 steps/min, and the middle three steps, free from direction changes, were chosen for data analysis. The same protocol was repeated after wearing Pedar-X (Novel Corporation, Munich, Germany), an insoletype plantar pressure measurement equipment with proven validity. The average maximum pressure (Ppeak, kPa) and the time at which Ppeak appeared (Ptime, %stride) were calculated for each device. The validity of smart insoles was evaluated by using the interclass correlation coefficient (ICC) of Ppeak and Ptime between the two instruments, and Cronbach's alpha was obtained from the Ppeak values to evaluate the reliability. Results: The ICC of Ppeak was 0.651 (good) in the hallux, 0.744 (good) in the medial forefoot, 0.839 (excellent) in the lateral forefoot, and 0.854 (excellent) in the hindfoot. The ICC of Ptime showed 0.868 (excellent) in the hallux, 0.892 (excellent) in the medial forefoot, 0.721 (good) in the lateral forefoot, and 0.832 (excellent) in the hindfoot. All ICC values showed good or excellent results. The Cronbach's alpha of Ppeak measured in the smart insoles was 0.990 in the hallux, 0.961 in the medial forefoot, 0.973 in the lateral forefoot, and 0.995 in the hindfoot; all indicated excellent reliability in all areas. Conclusion: The plantar pressure measurements of smart insoles during walking on a flat ground showed validity compared to Pedar-X, and high reliability after repeated measurements.

무지 외반증의 수술비 및 보험 (Operation Fee and Insurance Charge of Hallux Valgus Surgery)

  • 송하헌;심대무;김동철;권석현;김종윤
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.238-241
    • /
    • 2006
  • Purpose: The purpose of this study was to figure out the appropriate and systemic insurance charge for the hallux valgus operations. Materials and Methods: 5 Hospitals for hallux valgus operations were analyzed how they have been charging the national health insurance corporation for their operation fees and how to use the estimated guide and authoritive interpretation through the guide book of health insurance medical treatment grant expense and the guide book of Health insurance medical treatment. Results: There are nothing for guiding principle of hallux valgus operations in both books but a guide of Mcbride operation which is approved 'JA-93-KA and JA-31' for operation fee. So majority of hospitals have charged operation fee depending on their own interpretations they like. According to the guide books, there was a authoritive interpretation that simultaneous operation of osteotomy and tendon transfer for cerebral palsy and flat foot can be eatimated as 'osteotomy+JA-93-NA'. Conclusion: Distal soft tissue procedure should be approved as 'JA-93-NAx100%+JA-31x50%' according to the the estimated guide and authoritive interpretation if transected adductor hllucis is transfered to first metatarsal head. So distal chevron osteotomy could be 'JA-30-1-RAx100%+JA-31x50%', proximal metatarsal osteotomy could be 'JA- 93-NAx100%+JA-31-50%+JA-30-1-RAx50%', first metatarsocuneiform joint arthrodesis could be 'JA-93-NAx100%+ JA-31x50%+JA-73-RAx50%'.

  • PDF

The immediate effects of foot pressure based insole on ankle dorsiflexion range of motion, postural sway, and muscle activation in healthy adults with genu varum

  • Chun, Hye-Lim;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권4호
    • /
    • pp.164-171
    • /
    • 2018
  • Objective: The purpose of this research was to determine the immediate effects of wearing a foot-pressure-based insole (FPBI) on ankle dorsiflexion range of motion (DFROM), postural sway, and muscle activation in healthy individuals with genu varum. Design: Cross-sectional study. Methods: This study was conducted on thirteen adults, with six male and seven females subjects. The mean age was 24.08 years. Foot pressure was measured to apply the FPBI and the weight bearing lunge test was performed with the application of a flat insole (FI) and FPBI. Examination was randomly performed in four conditions to measure both postural sway and muscle activation. All participants applied both the FI and FPBI with four conditions. The four conditions were as follows: 1) Romberg test posture with eyes closed, 2) Romberg test posture with eyes opened, 3) dominant single leg standing with eyes opened, and 4) non-dominant single leg standing with eyes opened. Results: For ankle DFROM between the FI and FPBI, a significant increase was observed in both the dominant and non-dominant leg (p<0.05). For postural sway between the FI and FPBI in the Romberg test posture with eyes closed and dominant single leg standing with eyes opened conditions, a significant decrease was observed (p<0.05). However, the postural sway between FI and FPBI in the Romberg test posture with eyes opened and non-dominant single leg standing with eyes opened, no significant decrease was observed. Also, there were no significant effects on muscle activation between the application of the FI and FPBI. Conclusions: The result showed that FPBI immediately improved ankle DFROM and postural sway. It seems that FPBI may improve genu varum in healthy individuals with genu varum.

Analysis of the Plantar Pressure on the Flat and Slope Walking by Insole Type

  • Kim, Bu Gan;Lee, Joong Sook;Yang, Jeong Ok;Lee, Bom Jin
    • 한국운동역학회지
    • /
    • 제28권3호
    • /
    • pp.165-173
    • /
    • 2018
  • Objective: The purpose of this study is to provide biomechanical basis data for the analysis of the maximum vertical ground reaction force, the maximum plantar pressure, the average plantar pressure, and the contact area according to the type of the insole through the insole insertion type foot pressure gauge. Method: In the treadmill, the slope was set at 10%, the first type A was worn at a walking speed of 3.5 km / h, and then walking was carried out using B, C, and D types. Data from 20 boots with consistent walking were extracted and plantar pressure data were collected and analyzed. Results: Functional insole was more effective than conventional insole for maximum vertical ground reaction force, maximum plantar pressure, average plantar pressure, and contact area at 10% of treadmill ramps. Conclusion: In this study, D-type insole supports the cushion in the middle part and supports the heel cup with hardness in the hind part, so that it is the most effective insole by lowering the plantar pressure and dispersing it more widely.

정상아와 편마비 뇌성마비아의 삼차원 보행분석 (Three-Dimensional Video Analysis of the Gate Patterns in Normal Children and Hemiplegic Children with Cerebral Palsy)

  • 이진희;배성수;김중선
    • The Journal of Korean Physical Therapy
    • /
    • 제9권1호
    • /
    • pp.127-145
    • /
    • 1997
  • The purpose of this study wa9 to analyse the gait patterns of two female children with hemiplegic cerebral palsy by using the three-dimensional video motion analysis technique. Case 1 has mild spastic hemiplegia on the right side while Case 3 has moderate spastic hemiplegia on the left side. A group of 10, normal female children of the same age(7-8 years old) were selected as the control group for comparison. Time and distance variables as well as the Center of Mass displacement, and the pelvic and joint motions in three anatomical planes were analysed for this purpose. The following observations were made through the analysis : Case 1 revealed an asymmetrical gait pattern in which the step length of the unaffected side was shorter than that of the affected side, which wan a result of the effort to minimize loading on the affected leg by shortening the swing phase of the unaffected leg. Case 1 scored similar phase ratios, cadence and walking velocity to the normal group. A slight posterior tilt of the pelvis was observed throughout the gait cycle. Less hip and knee flexion than the normal group was observed, and demonstrated hyperextension of the knee in the terminal stance phase. The main problem in case 1 originated from the insufficient dorsiflexion of the affected foot during the swing phase. Therefore, Case 1 has difficulty with foot clearance in the swing phase. Usually, this is compensated for by using exessive hip abduction and medial rotation in conjuction with trunk elevation as well as increased vortical displacement of the center of mass. Case 1 revealed a foot-flat initial contact pattern. Case 2 was characterized by a consistent retraction ef the affected aide of the body througout the gait cycle, As a result, an asymmetrical gait pattern with increased stance phase ratios of the unaffected side was observed. In spite of this the step lengths of both sieds were similar. Case 2 scored lower cadence and walking speed than the normal group with lower gait stability. The main problem in Case 2 originated from an excessive plantaflexion of the affected foot which, in turn, rebutted in high hip and knee flexion. Hyperextension of the knee was observed at mid-stance, and execessive anterior tilt of the pelvis throughout the gait cycle was noticed. A gait pattern with high hip abduction and medial circumduction was maintained for the stability in the stance phase and foot clearance in the swing phase. Case 2 revealed a forefoot-contact initial contact pattern.

  • PDF