• Title/Summary/Keyword: Flash Fire

Search Result 198, Processing Time 0.024 seconds

Numerical study to reproduce a real cable tray fire event in a nuclear power plant

  • Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1571-1584
    • /
    • 2023
  • In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.

The Measurement and Estimation of Lower Flash Point for o-Xylene+n-Pentanol and m-Xylene+n-Hexanol Systems Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 o-Xylene+n-Pentanol 계와 m-Xylene+n-Hexanol 계의 하부인화점 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sung-Jin;Jeong, Kee-Sin
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.19-25
    • /
    • 2010
  • The flash points for the systems, o-xylene+n-pentanol and m-xylene+n-hexanol, were measured by using Tag open-cup tester(ASTM D1310-86). The experimental data were compared with the values calculated by the Raoult's law and the optimization method using van Laar and Wilson equations. The calculated values based on the optimization method were found to be better than those based on the Raoult's law. The predictive curve of the flash point prediction model based on the van Laar equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the Wilson equation.

Measurement and Prediction of Combustion Properties of Styrene (스티렌의 연소특성치 측정 및 예측)

  • Ha, Dong-Myeong;Na, Byeong-Gyun
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.70-76
    • /
    • 2013
  • For the safe handling of styrene, this study was investigated the explosion limits of styrene in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. As a results, the lower and upper explosion limits of styrene recommended 0.9 Vol.% and 8.0 Vol.%, respectively. The lower flash points of styrene by using closed-cup tester were experimented $29^{\circ}C{\sim}31^{\circ}C$. The lower flash points of styrene by using open cup tester were experimented $32^{\circ}C{\sim}36^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for styrene. The experimental AIT of styrene was $460^{\circ}C$.

A Study on the Optimal Flash-Point of WDF Production (유화유 생산의 적정 인화점에 관한 연구)

  • Lee, Jin;Kim, Hwaseong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.310-314
    • /
    • 2020
  • Although waste oil derived fuel (WDF) production technology was developed under a government initiative ~10 years ago, it became stagnant owing to the small size of participating companies, residents' rejection of foul odor, and the nature of the technology for recycling waste that was avoided. However, this subject is under the spotlight again because of recent developments, such as garbage crisis. In particular, plastic is the most difficult waste to dispose of, with more than 4 million tons of plastic waste produced every year according to statistics from the Ministry of Environment. The most effective method for treating plastic waste is to produce WDF through low temperature thermal decomposition. The WDF includes several volatile ingredients that mostly limit the use of fuel for boilers, owing to safety concerns. In particular, flash point is legally stipulated because of secondary contamination in the distribution process and the risk of fire and explosion. It is required that external shipments (distribution) should be maintained in the range of at least 30~60℃ (excluding explosion prevention facilities) for diesel power generation. Therefore, this study seeks to find the flash point that is best suited to WDFs produced from plastic waste.

Numerical Study on Atmospheric Dispersion and Fire Possibility in Toluene Leakage (톨루엔 누출 시 대기확산 및 화재가능성에 관한 수치해석 연구)

  • Ko, Jae Sun;Kim, Joo-Seok
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.1-10
    • /
    • 2017
  • This study examined the risk of accidents when handling hazardous materials in hazardous materials storage facilities without safety facilities. In the case of illegal dangerous cargo containers, the burning rate is very fast in the case of fire, which leads to explosions, that are damaging and difficult to control. In addition, accidents that occur in flammable liquid hazardous materials are caused mostly by accidents that occur in the space due to leakage. Therefore, the variables that affect these accidents were derived and the influence of these variables was investigated. Numerical and computational fluid dynamics programs were used to obtain the following final results. First, when a flammable liquid leaks into a specific space, it is influenced by temperature and relative humidity until a certain concentration (lower limit of combustion) is reached. In the case of temperature, it was found that the reaching time was shorter than the flash point In addition, the effect of variables on pool fire accidents of leakage tanks is somewhat different, but the variables that have the largest influence are the wind speed. Therefore, it is expected that the results of this study will be used as basic data for similar numerical analysis and it will provide useful numerical information about the accidental leakage of hazardous materials under various research conditions.

Effects of Antimony Trioxide-containing Coating on Fire Retardancy of Wood-based Materials (Antimony Trioxide가 첨가(添加)된 내화도료(耐火塗料)의 도막(塗膜)이 목질(木質) 판상재료(板狀材料)의 내화성(耐火性)에 미치는 영향(影響))

  • Yun, Young-Ki;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.31-42
    • /
    • 1992
  • In this study, the relative effectiveness of antimony trioxide-containing coat on fire retardancy of plywood, particleboard and medium density fiberboard was investigated and compared through ISO ignition test and inclined panel test with non-coated ones. The results obtained were summarized as fallows: Any treated materials was not ignited in inclined panel test with 5 minutes, but only particleboard among treated ones burned in ISO ignition test with fairly delayed time. The weight loss rate of plywood decreased with the increased addition level of fire-retardant and the least values were obtained in particleboard and MDF at addition level of 7% and 5% respectively. Carbonized area of wood based materials decreased with the increased addition level of fire retardant. The temperatures of back in plywood, particleboard treated with fire-retard ant coat containing 7% $Sb_2O_3$ showed the lowest but MDF did not show any effectiveness with the increased addition level. The first flash time of plywood treated with fire retardant coat containing 9% $Sb_2O_3$, MDF and particleboard treated with fire retardant coat containing 7% $Sb_2O_3$ were 257sec., 286.4sec., 165.4sec. respectively.

  • PDF

The Measurement of Lower Flash Point for tert-Pentanol+n-Decane System Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 tert-Pentanol+n-Decane 계의 하부인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.41-46
    • /
    • 2012
  • The flash point the lowest temperature at which the concentration of vapor of the substance in the air reaches the lower flammability limit(LFL), and is one of the most important physical properties used to determine the potential for fire and explosion hazards of industrial materials. The most published flash point data was for pure components and the flash points of the binary solutions that have flammable components, appear to be scarce in the literature. In the present study, the flash points of tert-pentanol+n-decane system were measured by Tag open-cup tester. The measured data were compared with the values calculated by the Raoult's law and the optimization methods based on the Wilson and NRTL equations. The calculated values by optimization methods were found to be better than those based on the Raoult's law.

A Study on Fire and Explosion Accident Cause in Regenerated Thermal Oxidizer (축열식 소각로의 화재.폭발 사고원인 규명 연구)

  • Lee, Keun-Won;Ma, Byung-Chol;Hwang, Soon-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.7-11
    • /
    • 2007
  • There has been a report of fire and explosion accident in regenerated thermal oxidizer (RTO). This paper was to investigate accident causes of RTO in the resin re-treatment process. The experiments carried out physicochemical properties and thermal stability analyses by using flash point tester, flammable range apparatus, autoignition tester, GC/MSD and thermal screening unit. We inferred causes of fire and explosion from the regenerated thermal oxidizer to prevent an accident of its process.

  • PDF

Analysis of a Fire in an Apartment Building Using a Zone Model (ZONE MODEL을 이용한 아파트에서의 화재 해석)

  • 박진국;김충익;유홍선;윤명오
    • Fire Science and Engineering
    • /
    • v.11 no.2
    • /
    • pp.25-33
    • /
    • 1997
  • Fire hazards in an apartment building that represents the average households in Korean were investigated by conducting a full-scale experiment. This experiment attempts to analyze fire hazards using materials, and furnishings common to Korean housing stock. Experimental results are compared to the predictions of the C-FAST and smoke transport computer model. Comparisons between experimental data and C-FAST data are performed only to a living-room fire. Flashover occurred at approximately 380 seconds in a fire experinent, and at approximately 420 seconds in Zone-Model. Based on all of data between experimental data between experimental data and Zone-Model data, it is concluded that the safe egress time is at least 250 seconds.

  • PDF