한국인에 있어 깊은아래배벽동맥(Deep Inferior Epigastric Artery)의 천공지(Perforator)에 관한 해부학적 연구 (Anatomical Study for Vascular Distribution of the Perforator of Deep Inferior Epigastric Artery in Koreans)

  • 김지훈;이백권;이종원;김덕임;한승호
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.28-35
    • /
    • 2008
  • Purpose: The pedicle of transverse rectus abdominis myocutaneous(TRAM) flap and deep inferior epigastric arterial perforator flap is deep inferior epigastic artery (DIEA) and accurate anatomic knowledge about perforator of DIEA is very important for the elevation of these flap. The authors investigated a detailed vascular network of perforator of DIEA in Koreans. Methods: 24 fresh cadavers were studied. Among them, 15 were examined based on the plain X-ray examination for the distribution and location of perforator of DIEA. And 9 fresh cadavers were examined based on the 3-dimensional computed tomography(CT) study for the distance between ending point of perforator of DIEA and mother artery, the distance between most medial mother artery and midline, the distance between most lateral mother artery and midline, and the running type of perforators of DIEA. Results: Based on the plain X-ray examination, suitable(external diameter$${\geq_-}0.5mm$$) perforators of DIEA are located between the level of umbilicus and 8 cm below it. Based on the 3D-CT study, average distance between the ending point of perforator of DIEA and the mother artery is 30.26 mm on the left, 28.62 mm on the right, respectively. The average distance between most medial mother artery and midline is 17.13 mm on the left, 15.76 mm on the right, respectively. The average distance between most lateral mother artery and midline is 56.31 mm on the left, 50.90 mm on the right, respectively. The main running course of suitable perforators of DIEA is type a, which is a direct musculocutaneous perforator vessel from main vascular axis passing outward to join the subdermal plexus, directly. Conclusion: 3-dimensional computed tomography study as well as plain X-ray examination provided more accurate and detail informations about perforators of DIEA in Koreans. These informations will help us understand the detailed vascular anatomy and operation with ease and safe in the lower abdomen of Koreans.

변형된 공장-장간막 복합 유리피판을 이용한 인두식도 재건 (Pharyngoesophageal Reconstruction Using Modified Jejunomesenteric Composite Free Flap)

  • 임진수;유결
    • 대한두개안면성형외과학회지
    • /
    • 제9권2호
    • /
    • pp.110-113
    • /
    • 2008
  • Purpose: The jejunal free flap is the most standard and reliable procedure of reconstruction of the circumferential pharyngoesophageal defect because it provides pliable, elastic, secreting mucosa and posses reliable vascular anatomy. In this report, the authors introduce the modification of jejunal free flap for decreasing the complications in fatty complicated patients. Method: After harvesting the jejunum with mesentery and mesenteric vessels, both ends of jejunum were excised remaining the mesenteric portion. The jejunal portion of this composite flap was placed to reconstruct esophagopharyngeal defect area and the mesenteric portion was used to obliterate the dead space at paratracheal region and to cover the vital structure and the vascular anastomotic region. Result: A 72 year-old man with recurrent hypopharyngeal cancer who had about 15 cm sized circumferential pharyngoesophageal defect after total pharyngectomy was reconstructed with jejunomesenteric composite free flap without any complications. Conclusion: The mesenteric flaps at both side of jejunomesenteric composite free flap provide the advantages that could obliterate dead space, that could provide cover for the vital cervical vascular structure in case of vascularity was compromised due to previous radiation therapy, and that could preserve as much vascularity at both ends of jejunal flap as possible.

횡복직근 유리 피판술후 공여부 합병증과 이환율 (Complication and Morbidity of Donor Site after Free TRAM Flap)

  • 안희창;성건용;조동인;최승석
    • Archives of Reconstructive Microsurgery
    • /
    • 제13권1호
    • /
    • pp.68-73
    • /
    • 2004
  • Transverse rectus abdominis muscle (TRAM) free flap is widely used for breast reconstruction, however donor-site morbidities such as abdominal wall weakness, hernia, bulging are troublesome. For the purpose of minimizing donor-site morbidity, there has been a surge in interests in muscle sparing free TRAM flap preserving the anatomy of rectus abdominis muscle, fascia, and motor nerve. The purpose of this study is to investigate complication and morbidity after muscle sparing free TRAM flap. Between August, 1995 and May, 2003, there were 108 cases of muscle sparing free TRAM flap of breast reconstruction. There was no abdominal hernia. There were 4 cases of dog ear, 3 cases of marginal necrosis of apron flap, 2 cases of asymmetry of umbilicus. At 1 year after operation, most patients feel comfortness in physical exercise. Muscle sparing free TRAM flap provides ample amount of well vascularized soft tissue with small inclusion of rectus abdominis muscle and fascia. Also it minimizes donor-site morbidity with rapid recovery of abdominal strength.

  • PDF

The Axillary Approach to Raising the Latissimus Dorsi Free Flap for Facial Re-Animation: A Descriptive Surgical Technique

  • Leckenby, Jonathan;Butler, Daniel;Grobbelaar, Adriaan
    • Archives of Plastic Surgery
    • /
    • 제42권1호
    • /
    • pp.73-77
    • /
    • 2015
  • The latissimus dorsi flap is popular due to the versatile nature of its applications. When used as a pedicled flap it provides a robust solution when soft tissue coverage is required following breast, thoracic and head and neck surgery. Its utilization as a free flap is extensive due to the muscle's size, constant anatomy, large caliber of the pedicle and the fact it can be used for functional muscle transfers. In facial palsy it provides the surgeon with a long neurovascular pedicle that is invaluable in situations where commonly used facial vessels are not available, in congenital cases or where previous free functional muscle transfers have been attempted, or patients where a one-stage procedure is indicated and a long nerve is required to reach the contra-lateral side. Although some facial palsy surgeons use the trans-axillary approach, an operative guide of raising the flap by this method has not been provided. A clear guide of raising the flap with the patient in the supine position is described in detail and offers the benefits of reducing the risk of potential brachial plexus injury and allows two surgical teams to work synchronously to reduce operative time.

How to Transform a Perforator Propeller Flap into a Keystone Flap in Case of Unsatisfying Perforator Vessel Local Perforator Flap Coverage in Limbs

  • Elena Ciucur;Hadj Boukhenouna;Benjamin Guena;I. Garrido-Stowhas;Christian Herlin;Benoit Chaput
    • Archives of Plastic Surgery
    • /
    • 제50권2호
    • /
    • pp.194-199
    • /
    • 2023
  • Moderate soft-tissue defects need stable coverage, ideally with tissue of similar characteristics and low donor site morbidity. We propose a simple technique for the coverage of moderate skin defects in the limbs. It allows intraoperative transformation of a propeller perforator flap (PPF) into a keystone design perforator flap (KDPF) in cases of unsatisfying perforator vessel or in cases of unpredictable intraoperative events. Between March 2013 and July 2019, nine patients with moderate soft-tissue defects (mean defect size 4.5 × 7.6 cm) in the limbs (two on the upper limbs and seven on the lower limbs) were covered using this technique. We performed four PPFs and five KDPFs. The mean follow-up was 5 months. There was one complication, partial distal tip necrosis in a PPF located in the leg, which healed by secondary intention within 3 weeks. The donor site was closed directly in all cases. No functional impairments were noted regardless of the perforator flap utilized. This technique enables us to employ flexible surgical strategies and allows us to make adjustments based on the patient's vascular anatomy.

Unusual anomaly of the radial artery encountered during the elevation of a radial forearm free flap: a case report

  • Jin Myung Yoon;Tae Jun Park;Sae Hwi Ki;Min Ki Hong
    • 대한두개안면성형외과학회지
    • /
    • 제24권1호
    • /
    • pp.28-31
    • /
    • 2023
  • The radial forearm free flap (RFFF) has become popular for head and neck reconstructions. Owing to a constant anatomy the RFFF is relatively easy to dissect. Nevertheless, anatomical variations of the radial artery have been reported. Some variations could affect the survival of the flap. This paper reports an unusual anomaly of the radial artery where the radial artery was not located between the brachioradialis (BR) and flexor carpi radialis. The radial artery was observed above the BR and on the radial side of the BR. The survival of the elevated flap was deemed questionable because it had only few perforators. So we decided to discard the flap and to elevate another free flap for the head and neck defect. The donor area on the forearm was covered using the original skin of the first flap as a full-thickness skin graft. This case highlights a means to deal with anomalies of the radial artery encountered during the elevation of RFFF and the checking process for variations of the radial artery before RFFF.

Immediate Bilateral Breast Reconstruction with Unilateral Deep Superior Epigastric Artery and Superficial Circumflex Iliac Artery Flaps

  • Hansen, Keith S.;Gutwein, Luke G.;Hartman, Brett C.;Sood, Rajiv;Socas, Juan
    • Archives of Plastic Surgery
    • /
    • 제43권5호
    • /
    • pp.457-460
    • /
    • 2016
  • Autologous breast reconstruction utilizing a perforator flap is an increasingly popular method for reducing donor site morbidity and implant-related complications. However, aberrant anatomy not readily visible on computed tomography angiography is a rare albeit real risk when undergoing perforator flap reconstruction. We present an operative case of a patient who successfully underwent a bilateral breast reconstruction sourced from a unilateral abdominal flap divided into deep superior epigastric artery and superficial circumflex iliac artery flap segments.

두경부재건을 위한 전외측 대퇴유리피판: 해부학적 연구 (ANTEROLATERAL THIGH FLAP FOR HEAD AND NECK RECONSTRUCTION : ANATOMIC STUDY)

  • 박주용;박현도;윤관현;곽현호;허경석;강현주;김회진;최성원
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권4호
    • /
    • pp.360-364
    • /
    • 2005
  • The anterolateral thigh flap was originally described in 1984 as a septocutaneous flap based on the descending branch of the lateral circumflex artery. This flap has some significant advantages for reconstruction of the head and neck. It can be raised as a subcutaneous flap, a fasciocutaneous flap, or a myocutaneous flap and can resurface large defects in the head and neck. In addition, it has a large and long vascular pedicle, and because of the distance of the donor site from the head and neck, it can easily be harvested with a 2-team approach. However, the number and locations of cutaneous perforators vary individually, and thus, it is not widely used because flap elevation is often complicated and time-consuming owing to unexpected anatomical variations. The purposes of this study are to classify the vascular anatomy and to assess the suitability of anterolateral thigh flap for head and neck reconstruction in Korean. We performed an anatomic study on cadavers and analyzed the anatomic pattern of the lateral circumflex femoral arterial system and the perforators nourishing the anterolateral thigh flap. This study suggest the characteristics of vascular anatomic patterns of anterolateral thigh flap of Korean and utility of this flap for head and neck reconstruction.

Using a Thermal Imaging Camera to Locate Perforators on the Lower Limb

  • Paul, Sharad P.
    • Archives of Plastic Surgery
    • /
    • 제44권3호
    • /
    • pp.243-247
    • /
    • 2017
  • Reconstruction of the lower limb presents a complex problem after skin cancer surgery, as proximity of skin and bone present vascular and technical challenges. Studies on vascular anatomy have confirmed that the vascular plane on the lower limb lies deep to the deep fascia. Yet, many flaps are routinely raised superficial to this plane and therefore flap failure rates in the lower limb are high. Fascio-cutaneous flaps based on perforators offer a better cosmetic alternative to skin grafts. In this paper, we detail use of a thermal imaging camera to identify perforator 'compartments' that can help in designing such flaps.

Indocyanine green fluorescence videoangiography for reliable variations of supraclavicular artery flaps

  • Suzuki, Yushi;Shimizu, Yusuke;Kasai, Shogo;Yamazaki, Shun;Takemaru, Masashi;Kitamura, Takuya;Kawakami, Saori;Tamura, Takeshi
    • Archives of Plastic Surgery
    • /
    • 제46권4호
    • /
    • pp.318-323
    • /
    • 2019
  • Background Pedicled flaps are useful for reconstructive surgery. Previously, we often used vascularized supraclavicular flaps, especially for head and neck reconstruction, but then shifted to using thoracic branch of the supraclavicular artery (TBSA) flaps. However, limited research exists on the anatomy of TBSA flaps and on the use of indocyanine green (ICG) fluorescence videoangiography for supraclavicular artery flaps. We utilized ICG fluorescence videoangiography to harvest reliable flaps in reconstructive operations, and describe the results herein. Methods Data were retrospectively reviewed from six patients (five men and one woman: average age, 54 years; range, 48-60 years) for whom ICG videoangiography was performed to observe the skin perfusion of a supraclavicular flap after it was raised. Areas where the flap showed good enhancement were considered to be favorable for flap survival. The observation of ICG dye indicated good skin perfusion, which is predictive of flap survival; therefore, we trimmed any areas without dye filling and used the remaining viable part of the flap. Results The flaps ranged in size from $13{\times}5.5cm$ to $17{\times}6.5cm$. One patient received a conventional supraclavicular flap, four patients received a TBSA flap, and one patient received a flap that was considered to be intermediate between a supraclavicular flap and a TBSA flap. The flaps completely survived in all cases, and no flap necrosis was observed. Conclusions The TBSA flap is very useful in reconstructive surgery, and reliable flaps could be obtained by using ICG fluorescence videoangiography intraoperatively.