• Title/Summary/Keyword: Flank

Search Result 486, Processing Time 0.029 seconds

Comparison of Paramedian and Flank Approaches for Abdominal Unilateral Cryptorchidectomy in Korean Native Calves (한우에서 복강 내 편측성 잠복고환 제거를 위한 부정중선 및 겸부 접근의 비교)

  • Jeong, Jae-Kwan;Baik, Young-Chul;Kang, Hyun-Gu;Kim, Ill-Hwa
    • Journal of Veterinary Clinics
    • /
    • v.30 no.1
    • /
    • pp.66-70
    • /
    • 2013
  • This report compared paramedian and flank approaches for the effective removal of abdominal unilateral cryptorchidism in calves. Two Korean native calves of approximately 300 kg in body weight, which had undergone the removal of a testis from the scrotum, were diagnosed as having abdominal unilateral (left) cryptorchidism by rectal palpation. One calf was administered with xylazine (0.2 mg/kg, IV) and was restrained in the dorsal recumbency position on the ground of barn for the paramedian approach, while the other calf was sedated with xylazine (0.03 mg/kg, IV) and restrained in the standing position for a flank approach. For the two calves, 2% lidocaine was administered by local infiltration, along the proposed incision line. Following incisions of the skin, muscle and peritoneum, the testis, which was located between the left kidney and inguinal canal, was grasped, exteriorized out of the abdominal cavity and detached from the gubernaculum testis. Then spermatic cord was ligated and cut. Finally, the testis was removed. An assistant was required to restraint a calf in dorsal recumbency for paramedian approach, and cryptorchidectomy was carried out with operator in a rather uncomfortable squatting posture, while restraint was rather simple and cryptorchidectomy was proceeded with operator in a standing posture where the flank approach was taken. During surgery, the gubernaculum testis was more strained during pulling the testis in the flank approach than in the paramedian approach, as the distance between incision site and the gubernaculum testis was greater in the flank approach than that in the paramedian approach. On the other hand, intra-abdominal pressure was greater in the paramedian approach than in the flank approach during surgery. The elapsed time between restraint and the end of surgery was 10 min shorter where the flank approach (35 min) was taken, than where the paramedian approach (45 min) was taken. In conclusion, this case study demonstrated that the flank approach might be more convenient than the paramedian approach for abdominal unilateral cryptorchidectomy in calves.

A Study on Lipids Oxidation Boiled Whale Meat’s in Process of Circulation Market (유통되고 있는 삶은 고래고기의 안정성 연구)

  • 최민경;김경옥
    • Korean Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.33-41
    • /
    • 2004
  • The purpose of the study was to analyze in process of circulation market boiled whale meat's rancidity. oxidative rancidity is oil or fat food depend on oxygen in air oxidative change in quality. boiled whale meat faty come to oxidative rancidity food stability and hygiene reasons for people health poisonous point out, however it is not indication study of support. Accordingly confirm lead into circulation process boiled whale meat's rancidity examination and microorganism examination boiled whale meat's stability whether or not. The result obtained were summarized as follows: 1. Proximate percentage of boiled whale meat(pectoral, pelvic, fin, flank) of moisture and crude lipid and crude protein from samples shown to be : moisture was pectoral 16.4%, pelvic 36.2%, fin 46.2%, flank 19.2%, crude lipid was pectoral 54.1%, pelvic 42.8%, fin 15.8%, flank 40.6%,crude protein was pectoral 29.4%, pelvic 20.5%, fin 29.5%, flank 28.6%. 2. The fatty acid composition of total lipid were composed of pectoral 27.2%, pelvic 28.9%, fin 33.3%, flank 23.4% of oleic acid and pectoral 12.7%, pelvic 11.1%, fin 11.3%, flank 14.0% of palmitic acid pectoral 10.8%, pelvic 7.9%, fin 7.6%, flank 2.1% of docosahexaenoic acid, pectoral 14.2%, pelvic 7.5%, fin 1.9%, flank 7.2% of eicosenoic acid, pectoral 5.1%, pelvic 5.7%, fin 4.4%, flank 5.7% of myristic acid, 16: 0 11∼14 % of high saturated fatty acid. generally most of 18: 1ω9 of boiled whale meat's each portion, 22:6 7∼12%, 20:5 1∼14% of polyenoic fatty acid. 18:3 showen to be 1% make an expection of pectoral and fin portion the total lipid were most of netural lipid's about 90%, monoenic fatty acid were most of 19∼22% of saturated fatty acid, 77∼80% of monoenic fatty acid level of 47∼56% of 18:1 16:1 was markelly high to those of total lipid. 3. The storage number days variation of oxidation were shown to be by stages process favorably the past days of boiled whale meat's acid value for 5days. pectoral the day 0.1, five days 1.3, pelvic the day 0.1, five days 1.6, fin the day 0.3, five days 0.7, flank the day 0.2, five days 0.4. 4. The sealer and wrapper the storage number days variation of boiled whale meat oxidation for 7days were shown to be a stage of sealing, the temperature of a room, pectoral the day 0.1 seven days 0.6, pelvic the day 0.1, seven days 1.3, fin.

  • PDF

The Literature Study on Medical treatments with acupuncture and Moxibustion of Flank pain (협통(脇痛)의 침구치료혈(鍼灸治療穴)에 대(對)한 문헌적(文獻的) 고찰(考察))

  • Park, Ki-Young;Lee, Jun-gu;Kim, Young-il;Park, Tae-gyun;Shin, Young-il;Hwang, Jae-yeon;Lee, Hyen;Lee, Byung-ryul
    • Journal of Haehwa Medicine
    • /
    • v.10 no.2
    • /
    • pp.97-106
    • /
    • 2002
  • As mentioned above, I have acquired some valuable results about medical treatment with acupuncture and Moxibustion of "Flank pain" after studying oriental medical books. The results were like below : 1. Medical treatment with acupunctures of Flank pain belonged to the Urinary Bladder Meridian of Foot Taiyang, the Liver Meridian of Foot Jueyin, the Gall Bladder Meridian of Foot Shaoyang. 2. Medical treatment with acupunctures of Flank pain used to Yang-laung-chan(陽陵泉), Gi-gu(地溝), Gi-mun(期門), Kan-su(肝兪) in turn. 3. Medical treatment with Ear acupunctures of Flank pain used to Dam(膽), Sin-mun(神門), Gan(肝)in turn. 4. Acupuncture point of Flank pain were lower limb part, chest and abdominal part. back part in turn. 5. Medical treatment with Moxibustion of Flank pain was the most Jang-mun(章門)

  • PDF

Flank Reconstruction of Large Soft Tissue Defect with Reverse Pedicled Latissimus Dorsi Myocutaneous Flap: A Case Report (옆구리 부위의 거대 연부조직 결손에 대한 역넓은등근 근육피부피판을 이용한 치험례)

  • Song, Seung-Yong;Kim, Da-Han;Kim, Chung-Hun
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.894-898
    • /
    • 2011
  • Purpose: Coverage of full-thickness large flank defect is a challenging procedure for plastic surgeons. Some authors have reported external oblique turnover muscle flap with skin grafting, inferiorly based rectus abdominis musculocutaneous flap, and two independent pedicled perforator flaps for flank reconstruction. But these flaps can cover only certain portions of the flank and may not be helpful for larger or more lateral defects. We report a case of large flank defect after resection of extraskeletal Ewing's sarcoma which is successfully reconstructed with reverse latissimus dorsi myocutaneous flap. Methods: A 24-year-old male patient had $13.0{\times}7.0{\times}14.0$ cm sized Ewing's sarcoma on his right flank area. Department of chest surgery and general surgery operation team resected the mass with 5.0 cm safety margin. Tenth, eleventh and twelfth ribs, latissimus dorsi muscle, internal and external oblique muscles and peritoneum were partially resected. The peritoneal defect was repaired with double layer of Prolene mesh by general surgeons. $24{\times}25$ cm sized soft tissue defect was noted and the authors designed reverse latissimus dorsi myocutaneous flap with $21{\times}10$ cm sized skin island on right back area. To achieve sufficient arc of rotation, the cephalic border of the origin of latissimus dorsi muscle was divided, and during this procedure, ninth intercostal vessels were also divided. The thoracodorsal vessels were ligated for 15 minutes before divided to validate sufficient vascular supply of the flap by intercostal arteries. Results: Mild congestion was found on distal portion of the skin island on the next day of operation but improved in two days with conservative management. Stitches were removed in postoperative 3 weeks. The flap was totally viable. Conclusion: The authors reconstructed large soft tissue defect on right flank area successfully with reverse latissimus dorsi myocutaneous flap even though ninth intercostal vessel that partially nourishes the flap was divided. The reverse latissimus dorsi myocutaneous flap can be used for coverage of large soft tissue defects on flank area as well as lower back area.

A Case of Pelvic Congestion Syndrome Presenting with Chronic Left Flank Pain in an Adolescent Girl (청소년기 여아에서 만성적인 좌측 측복부 통증으로 진단된 골반울혈증후군 1례)

  • Kim, Sung-Jin;Shim, Hae-Sun;Kang, Sung-Gil;Son, Byong-Kwan;Lee, Byong-Ik;Cho, Soon-Ku;Lee, Ji-Eun
    • Childhood Kidney Diseases
    • /
    • v.11 no.1
    • /
    • pp.126-131
    • /
    • 2007
  • Flank Pain is a leading indicator of renal and upper urinary tract disease or trauma, and rarely results from pelvic congestion syndrome. Although pelvic congestion syndrome occurs commonly in multi-parous women, pelvic congestion syndrome should also be considered as the cause of flank pain in an adolescent girl. We report the first case of pelvic congestion syndrome presenting with chronic left flank pain in an adolescent girl.

  • PDF

A Study of New Wuick Tool-Life Tesing Method(I) - The Analysis of the Wear Behavior for Carbide Tool - (새로운 급속 工具壽命試驗法에 관한 硏究 (I) - 초경공구의 유동거동 분석-)

  • 오양균;정동윤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.223-231
    • /
    • 1986
  • During the past decade, the Quick Tool-Life Testing Method has been studied. However, a generalized theory and testing method for the quantitative measurement of tool wear have not been developed yet. Among many factors to affect the tool wear, the flank wear is regarded as a main factor. In this study, the behavior of the flank wear for carbide tool was studied as a preceding step to present a simple method for Quick Tool-Life Testing, and it was found that the flank wear varies in direct proportion to cutting time, and the following general equation is obtained for the flank wear curves with respect to cutting time and velociety.

Effect of Support Surface Form on Abdominal Muscle Thickness During Flank Exercise (플랭크 운동 시 지지면의 형태가 복부 근육의 두께 변화에 미치는 영향)

  • Kim, Hyeonsu;Lee, Keoncheol
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.3
    • /
    • pp.197-204
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the effects of the plank exercise to strengthen the core muscles on the muscle thickness of external and internal obliques and transverse abdominis muscle depending on the form of the support surface. Methods: This study was randomized to 12 males and 12 females in their 20s and conducted three times a week for 4 weeks. The subjects were divided into the two groups and performed flank exercise on a stable surface (stable surface group) and an unstable surface (unstable surface group). A mat was used as a stable surface, and an TOGU used as a unstable surface. Results : In both stable and unstable surface, the thickness changes of the transverse abdominis and external and internal oblique muscle increased (p<.05). In the unstable surface, there was a greater increase in the thickness change of the transverse abdominis and external oblique muscles in the flank exercise than in the stable surface (p.<05). Among them, the greatest increase was found in the external abdominal muscle (p<.05). Conclusion : This study found that the flank exercise was more effective in strengthening the abdominal muscles on an unstable surface, when compared with the outcomes on a stable one. It is also thought to have the most effect on the muscle activity of the external oblique muscle on unstable surface.

A Study on Machining for Bearing Rubber Seal Die by Flank of Formed Insert Type Tool (Insert type 총형공구 여유각 영향에 따른 베어링 Rubber Seal 금형의 가공성 평가)

  • Li-Hai Li
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.42-47
    • /
    • 2004
  • Formed insert type tool satisfy both the surface roughness and geometric accuracy, so that cutting edge of formed tool can duplicate final feature. For experiment the formed tools with various clearance angles are machined. And the tools are evaluated with respect cutting force, flank rear and surface roughness to optimistic condition.

  • PDF

이미지 프로세싱을 위한 드릴 마모측정에 관한 연구

  • 양승배;김영일;유봉환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.298-301
    • /
    • 1992
  • A digital image processing approach has been adopted to measure the flank wear area, which is very difficult to measure using conventional techniques. Automatic thresholding of the gray-level values of an image is very useful in automated analysis of image. 1-D entropy thresholding technique is used for image processing and analysis of the flank wear area. This strategy provides more information about drill wear conditions and should therefore have a higher reliability than previous methods. This study calulated quantitatively the flank were area of drill by computer program.

The Automated Measurement of Tool Wear using Computer Vision (컴퓨터 비젼에 의한 공구마모의 자동계측)

  • Song, Jun-Yeop;Lee, Jae-Jong;Park, Hwa-Yeong
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.69-79
    • /
    • 1989
  • Cutting tool life monitoring is a critical element needed for designing unmanned machining systems. This paper describes a tool wear measurement system using computer vision which repeatedly measures flank and crater wear of a single point cutting tool. This direct tool wear measurement method is based on an interactive procedure utilizing a image processor and multi-vision sensors. A measurement software calcultes 7 parameters to characterize flank and crater wear. Performance test revealed that the computer vision technique provides precise, absolute tool-wear quantification and reduces human maesurement errors.

  • PDF