• 제목/요약/키워드: Flame-flame interactions

검색결과 44건 처리시간 0.028초

LES기반 연소모델과 Helmholtz 방정식을 이용한 LIMOUSINE 버너의 연소불안정 해석 (Combustion Instability Analysis of LIMOUSINE Burner using LES-based Combustion Model and Helmholtz Equation)

  • 신영준;전상태;김용모
    • 한국연소학회지
    • /
    • 제22권3호
    • /
    • pp.41-46
    • /
    • 2017
  • This study has numerically investigated the flame-acoustics interactions in the turbulent partially premixed flame field. In the present approach, in order to analyze the combustion instability, the present approach has employed the LES-based combustion model as well as the Helmholtz solver. Computations are made for the validation case of the partially premixed LIMOUSINE burner. In terms of the FFT data, numerical results are compared with experimental data. Moreover, Helmholtz equation in frequency domain is solved by combining CFD field data including the flight time from a nozzle to the flame zone. Based on numerical results, the detailed discussions are made for the essential features of the combustion instability encountered in the partially premixed burner.

CH-OH PLIF와 Stereoscopic PIV동시계측에 의한 난류예혼합화염의 관찰 (Simultaneous Measurements of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames)

  • 최경민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제29회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.91-96
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry (PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Reynolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Reynolds number turbulent premixed flame. The Reynolds number dependence of the flame front was clearly captured by the simultaneous CH-OH PLIF and stereoscopic PIV measurements.

  • PDF

CH-OH PLIF와 Stereoscopic PIV계측법을 이용한 난류예혼합화염의 관찰 (Simultaneous Measurement of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames)

  • 최경민
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.102-103
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry(PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Renolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Renolds number turbulent premixed flame.

  • PDF

직사각형 폭발 챔버에서 화염전파와 직사각형 장애물의 상관관계 (Interactions Between a Propagating Flame and Rectangular Wall Obstacles in a Rectangular Confinement)

  • 박달재;이태성;이영순
    • 한국안전학회지
    • /
    • 제23권2호
    • /
    • pp.81-86
    • /
    • 2008
  • 직사각형 폭발 챔버에서 전파하는 화염과 직사각형 장애물의 상관관계를 조사하기 위한 실험적 연구가 수행되었다. 챔버내에 10%, 20%및 30%의 blockage ratio를 가지는 3가지 직사각형 장애물들이 사용되었다. 전파하는 화염과 장애물의 상관관계를 조사하기 위해 고속카메라가 사용되었다. 고속카메라로 얻어진 화염 이미지로부터 장애물 주위의 국부 화염속도 및 그 화염속도의 확률밀도함수가 계산되었다. 실험결과, 전파하는 화염이 직사각형 장애물의 모서리와 상호작용할 때 국부 화염속도는 증가하였다. 그 증가속도는 장애물의 Blockage Ratio가 증가할 때 더욱 커지는 것으로 나타났다. 그러나, 평균화염속도는 Blockage Ratio에 큰 의존성을 가지지 않는 것으로 나타났다. 이 연구에서 사용된 작은 L(Lenlgth)/D(Diameter)비를 가지는 폭발 챔버내에서 전파하는 화염전면과 직사각형 장애물과의 상관관계는 L/D비가 큰 문헌에서 보고된 결과와 비교하면, Blockage Ratio에 따른 의존성은 작은 것으로 나타났다.

합판(合板)의 내화처리(耐火處理)에 관(關)한 연구(硏究) - III. 제1인산(第一燐酸)암모늄처리합판(處理合板)의 내화도(耐火度) (Studies on Plywood Treated Fire-Retardant - III. The Fire-Retardant Degree of Monoammonium Phosphate Treated Plywood)

  • 김종만
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권4호
    • /
    • pp.21-28
    • /
    • 1986
  • Plywood used for construction as a decorative inner material is inflammable and can fire accident, causing destruction of human life and property. In this study, 3.5mm Kapur plywoods were soaked in the 23% monoammonium phosphate solutions by cold soaking method 3, 6, 9hrs and hot-cold bath method for 3/3hrs, and redrying was carried out by press-drying at the platen temperature of 110, 130, 160, 180$^{\circ}C$, and then fire test was carried out to investigate burning point, flame exhausted length, frame spread length, back side carbonized area and weight loss. The results are as follows; 1. In cold soaking method for 3, 6, 9hrs. retentions of monoammonium phosphate were 0.377, 0.448, 0.498kg/(30cm)$^3$ respectively, and in hot-cold bath method for 3/3hrs, the retention was 1.331kg(30cm)$^3$ that exceeded the minimum retention 1.124kg/(30cm)$^3$. 2. Correlation coefficients among the variable were shown in table 2. From the table, it could be recognized that there were close negative correlations between the treatment and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, and there was negative correlation between treating time and back side carbonized area, but there was positive correlation between platen temperature and burning point. 3. From table 3, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carhonized area, weight loss between treatments. And in 2-way interactions, there were also highly significant for burning point, flame spread length, flame exhausted time, weight loss between time x treatment. 4. It was observed that burning point, flame exhausted time, flame spread length, back side carbonized area, and weight loss in fire-retardant treated plywood were the best effects in fire-retardant treated plywood, water treated plywood and nontreated plywood. In conclusion, I can estimate that absorbed chemical contents by hot-cold bath method for 3/3hrs, have a lot of effects on fire-retardant factors such as burning point, flame spread length, flame exhausted time, backside carbonized area and weight loss, but platen temperatures have a little effects on the fire factors.

  • PDF

상호작용 하는 H2-공기/CO-공기 예혼합화염에 미치는 H2 선호 확산 영향에 대한 수치적 연구 (Numerical Study on H2 Preferential Diffusion Effect in Downstream Interactions between Premixed H2-air and CO-air Flames)

  • 정용호;박정;권오붕;길상인;윤진한
    • 한국연소학회지
    • /
    • 제18권4호
    • /
    • pp.37-43
    • /
    • 2013
  • The effects of preferential diffusion of hydrogen in interacting counterflow $H_2$-air and CO-air premixed flames were investigated numerically. The global strain rate was varied in the range $30-5917s^{-1}$, where the upper bound of this range corresponds to the flame-stretch limit. Preferential diffusion of hydrogen was studied by comparing flame structures for a mixed average diffusivity with those where the diffusivities of H, $H_2$ and $N_2$ were assumed to be equal. Flame stability diagrams are presented, which show the mapping of the limits of the concentrations of $H_2$ and CO as a function of the strain rate. The main oxidation route for CO is $CO+O_2{\rightarrow}CO_2+O$, which is characterized by relatively slow chemical kinetics; however, a much faster route, namely $CO+OH{\rightarrow}CO_2+H$, can be significant, provided that hydrogen from the $H_2$-air flame is penetrated and then participates in the CO-oxidation. This modifies the flame characteristics in the downstream interaction between the $H_2$-air and CO-air flames, and can cause the interaction characteristics at the rich and lean extinction boundaries not to depend on the Lewis number of the deficient reactant, but rather to depend on chemical interaction between the two flames. Such anomalous behaviors include a partial opening of the upper lean extinction boundary in the interaction between a lean $H_2$-air flame and a lean CO-air flame, as well as the formation of two islands of flame sustainability in a partially premixed configuration with a rich $H_2$-air flame and a lean CO-air flame. At large strain rates, there are two islands where the flame can survive, depending on the nature of the interaction between the two flames. Furthermore, the preferential diffusion of hydrogen extends both the lean and the rich extinction boundaries.

붕산처리(硼酸處理) 합판(合板)의 열판건조(熱板乾燥) 및 동적(動的) 탄성율(彈性率)에 관(關)한 연구(硏究) (Studies on Press Drying and Dynamic Elastic Modulus of Plywood Treated with Boric Acid)

  • 김종만
    • Journal of the Korean Wood Science and Technology
    • /
    • 제15권3호
    • /
    • pp.56-67
    • /
    • 1987
  • Plywoods used for construction as a decorative interior material are inflammable and can make fire accidents, causing destruction of human life and property. Therefore, it is indeed required to make fire-retardant treated plywood. In this study, 3.7mm yellow meranti plywoods were soaked in 18% boric acid solutions and tap water by hot-cold bath for 1/2, 2/2, 4/2, 6/2 hours and redrying of treated plywoods was carried out by press drying at the platen temperature of 110, 130, 160, $180^{\circ}C$ and then it was conducted to investigate solution absorption, drying rates, dynamic young's modulus. specific gravity and fire-retardant factors such as burning point, flame spread length. flame exhausted time, back side carbonized area and weight loss by treating time, treating solutions and platen temperature. The results are as follows; 1. When plywood was impregnated with the hot bath temperature of $70^{\circ}C$ for 1. 2, 4, 6 hours and the cold bath temperature of $15^{\circ}C$ for 2 hours respectively, retentions of boric acid were 1.565, l.597, 1.643, 1.709kg/$(30cm)^3$ and all of them exceeded the minimum retention [1.125kg/$(30cm)^3$] even in the shortest treatment. 2. In hot-cold bath method for 1/2 hours, the drying rates of treated plywood remarkably increased with the extension of platen temperature of 110, 130, 160, $180^{\circ}C$ and the values of boric acid treated plywood were 5.900, 10.196, 45.42, 54.958m.c%/min and the values of water treated plywood were 6.014, 12.373, 46.520, 55.730m.c%/min and drying rates of water treated plywood were faster than those of boric acid treated plywood. 3. The values of boric acid treated plywoods in dynamic young's modulus were widely higher than those of water treated plywoods. And it can be observed that there were highly significant differences for treating time between dynamic young's modulus, and the values of boric acid plywoods increased with the extension of treating time but on the contrary water treated plywoods were decreased values with prolonged time 4. It was observed that there were highly significant differences for platen temperature between dynamic young's modulus. When the values of water treated plywoods in dyna nic young's modulus were abruptly decreased according to the rise of platen temperature. boric acid treated plywoods showed rather increased values at $160^{\circ}C$ of platen temperature. And in 2- way interactions, there were also highly significant for dynamic young's modulus between treating time x treating solutions and platen temperature x treating solutions. 5. Correlation coefficients of fire-retardant factors were shown in table 5. It could be recognized that there were close correlations between the treating solutions and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, but there was no correlation between fire-retardant factors and treating time and platen temperature. 6. From table 6, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carbonized area, weight loss between treating solutions. And in 2-way interactions, there were highly significant for burning point, flame spread length, weight loss between treating time $\times$ treating solutions.

  • PDF

예혼합화염의 불안정성 및 비선형적 거동에 관한 수치적 연구 (Numerical Study on the Premixed Flame Instability and Nonlinear Behavior)

  • 강상훈;백승욱;임홍근
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.281-286
    • /
    • 2005
  • To understand fundamental characteristics of combustion in a small scale device, the effects of the momentum and heat loss on the stability of laminar premixed flames in a narrow channel are investigated by two-dimensional high-fidelity numerical simulation. A general finding is that momentum loss promotes the Saffman-Taylor (S-T) instability which is additive to the Darrieus-Landau (D-L) instabilities, while the heat loss effects result in an enhancement of the diffusive-thermal (D-T) instability. These effects are also valid in nonlinear behavior of the premixed flame. The simulations of multiple cell interactions are also conducted with heat and momentum loss effects.

  • PDF

가연성 기체 혼합물에서 복잡한 구조에 따른 화염 가속 모델링 (Modeling of Flame Acceleration Considering Complex Confinement Effects in Combustible Gas Mixture)

  • 곽민철;여재익
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.315-324
    • /
    • 2012
  • 본 연구는 가연성 기체로서 에틸렌-공기 혼합물로 채워져 있는 관에서 장애물과 굽은 관에 의한 지형적 효과에 따라 변화하는 충격파와 화염의 상호 작용, 화염 가속, 연소폭발천이 현상을 수치적으로 살펴보았다. 여기서 사용되는 모델은 지배방정식으로 Navier-Stokes 방정식과 경계조건 처리 방법으로 ghost fluid 기법을 사용하였으며 지형적 영향을 달리한 여러 모델링을 통하여 화염과 강한 충격파의 충돌에 의한 열점 생성과 화염 전파의 지연 혹은 가속 현상을 확인하였다. 추가적으로 평균 화학적 에너지 발생률이 대략 20 MJ/($g{\bullet}s$)에서 폭굉으로 천이한다는 사실을 확인하였다. 그리고 동일 위치 열점 생성에도 불구하고 폭굉의 발생 시기가 반응물의 부재와 화염면 전방의 온도와 압력 차에 의해 지연될 수 있음을 확인하였다.

동축공기 수소확산 화염에서의 화염과 와류의 상호작용 실험연구 (Experimental Study on Flame-Vortex Interactions in Turbulent Hydrogen Non-premixed Flames with Coaxial Air)

  • 김문기;오정석;최영일;윤영빈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.86-94
    • /
    • 2006
  • This paper investigates the effects of acoustic forcing on NOx emissions and mixing process in the near field region of turbulent hydrogen nonpremixed flames. The resonance frequency was selected to force the coaxial air jet acoustically, because the resonance frequency is effective to amplify the forcing amplitude and reduce NOx emissions. When the resonance frequency is acoustically excited, a streamwise vortex is formed in the mixing layer between the coaxial air jet and coflowing air. As the vortex develops downstream, it entrains both ambient air and combustion products into the coaxial air jet to mix well. In addition, the strong vortex pulls the flame surface toward the coaxial air jet, causing intense chemical reaction. Acoustic excitation also causes velocity fluctuations of coaxial air jet as well as fuel jet but, the maximum value of centerline fuel velocity fluctuation occurs at the different phases of $\Phi$=$180^{\circ}$ for nonreacting case and $\Phi$=$0^{\circ}$ for reacting case. Since acoustic excitation enhances the mixing rate of fuel and air, the line of the stoichiometric mixture fraction becomes narrow. Finally, acoustic forcing at the resonance frequency reduces the normalized flame length by 15 % and EINOx by 25 %, compared to the flame without acoustic excitation.

  • PDF