• 제목/요약/키워드: Flame interference

검색결과 28건 처리시간 0.019초

적외선식 불꽃감지기의 전자파 적합성 개선 (Improving Electromagnetic Compatibility of the Infrared Flame Detector)

  • 송현선;이의용
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.88-95
    • /
    • 2014
  • The infrared, flame detector uses to detect fire situation from the characteristics of fire sources radiant energy. But it is able to malfunction on account of susceptible to interference of various surrounding waves. This paper is designed 6 independent PCB-boards to minimize the closed loops of siginal circuit. Also considering the interaction of electric and magnetic fields, this paper is designed protecting circuit of current and voltage output to reduced electromagnetic interference. And this paper is improving electromagnetic susceptibility by ferrite bid, capacitor filter and grounding circuits.

FLAME DETECTOR의 응답특성연구

  • 이복영
    • 방재기술
    • /
    • 통권18호
    • /
    • pp.5-16
    • /
    • 1995
  • The capacity commonly required sensors includes capability of quickly and properly catching the conditions of a fire and discriminating other factors such as noise, interference, etc. IR flame detector which react to the infra-red rays emitted from the flame. This study is aimed to know the characteristic repond to the specified fire plate. Experiment is acted by manufacture's technical data that is explained relation of detective range and sensitivity.

  • PDF

슬릿버너에서 형상변화가 연소특성 및 배기배출물에 미치는 영향 (The study of combustion characteristics and emissions with the variation of design factor on slit gas burner)

  • 김태우;조승완;장영준;전충환
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.314-319
    • /
    • 2005
  • In this study, the combustion characteristics were investigated with the variation of design factors on multiple slit gas burner. The design factors consist of slit height, width, spacing, and inner length. The combustion characteristics were made analysis of the CO emission and NOx emission by using CO analyzer and NOx analyzer. The lower perimeter to area and the narrow spacing extends the lift-flame limit. The CO emission increases with the increasing perimeter to area ratio at the same condition. The NOx emission is found to be less significant with the port perimeter to area ratio. The flame interference might highly depend on the spacing and port perimeter to area ratio, and it also affects the burner performance.

  • PDF

아르곤이온 레이저를 이용한 확산화염 내 PAH의 LIF 신호 측정에 LII 신호가 미치는 영향 (The Effect of LII Interference on the Measurement of PAH's LIF Signals using Ar-Ion Laser)

  • 안태국;배승만;이원남;박선호
    • 한국연소학회지
    • /
    • 제23권1호
    • /
    • pp.1-7
    • /
    • 2018
  • The effect of LII interference on the measurement of LIF signals from PAH in a diffusion flame has been investigated. Argon-ion laser at 488 nm was vertically or horizontally polarized, and irradiated to the centerline of the flame at varying flame height. Signals from PAH-rich regions measured at 515 nm were mostly LIF signals, however, signals from soot-rich regions were determined to be mixed with Mie scattering signals and/or LII signals. Signals measured 1 mm above the excitation height were mostly LII signals from soot particles. The results show that a quantitative determination of the LIF's contribution to the measured signals would be difficult as long as the experimental setup described here is used for the regions where PAHs and soot particles exist together.

마이크로프로세서를 사용한 UV/IR 불곶 감지기 (UV/IR flame detector using Microprocessor)

  • 박성진;임병현;임종연;김명원;윤길호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

토양 시료 중 Atomic Absorption Spectrometry (AAS) 및 Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES)를 이용한 총 크롬 분석방법 비교 (Comparison of analytical methods for quantifying total chromium in soil using Atomic Absorption Spectrometer (AAS) and Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES))

  • 이홍길;김지인;변윤주;김현구;윤정기
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권6호
    • /
    • pp.22-28
    • /
    • 2017
  • The accuracy of analytical results in response to the use of different additives ($NH_4Cl$, KCl, $LaCl_3$) and oxidant gases was evaluated and compared by using Atomic Absorption Spectrometry (AAS). Identification of spectroscopic interferences and possible improvements in Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) analysis were also discussed. The average accuracies of total chromium using Certified Reference Materials (CRMs) were found to be 72.1~94.2% in air/acetylene flame condition by AAS, and they were improved to 100.5~110.5% when the oxidants was changed to nitrous oxide rather than adding the additives. The field samples showed similar trends to CRMs, but chromium concentrations were highly variable depending on analytical conditions. The average accuracies using CRMs were estimated to be 89.3~166.1% by ICP-AES, and improved to below 121.7% after eliminating iron interference. Field samples with low chromium and high iron concentration were measured to be > 30% lower in total chromium concentrations by ICP-AES than AAS in nitrous oxide/acetylene flame. Total chromium concentrations in soil could be analyzed with better accuracy under nitrous oxide/acetylene flame by AAS because it was more effective to increase the temperature of the flame than to eliminate the chemical interference for maximizing atomization of chromium. When using ICP-AES, interference substances, total chromium levels, and analytical conditions should be also considered.

저공해 연소를 위한 화염진단장치의 특성 (Advanced flame quality indicator for emission control)

  • 김종원;이상호;박기배;심규성
    • 센서학회지
    • /
    • 제5권6호
    • /
    • pp.43-50
    • /
    • 1996
  • 대부분을 수입에 의존하고 있는 연료의 연소효율 증대, thermal NOx의 배출 저감은 화염특성 감지 및 분석을 통해서도 가능하다. 연소시스템에서 화영의 flicker에 대한 정보를 퓨리어 변환을 통해 frequency domain data 로 변환시켜 해석한 결과, 일반적으로 연소 영역의 난류강도가 커질수록 frequency와 강도는 커졌으며, 화염의 강도는 연료 공급 유량이 커질수록 항께 커졌다. 선회도가 $0{\sim}1.16$ 범위에서 커질 때, 화염의 강도는 작아졌다. 시험 연소로의 관찰구를 통하여 얻은 신호는 화염유무에 따라 그 차이가 매우 커서 화염의 존재 유무를 쉽게 알 수 있었다. 발생되는 NOx의 양은 화염강도와 밀접한 관계가 있음을 보여주었다.

  • PDF

레이저 유도 형광법(LIF)을 이용한 버너 화염의 NO 농도측정에 관한 연구 (A Study on Measurement of NO Concentrations in Burner Flames by LIF)

  • 박경석;김성욱
    • 한국분무공학회지
    • /
    • 제7권4호
    • /
    • pp.42-49
    • /
    • 2002
  • In this study, quantitative measurement of nitric oxide concentration distributions were investigated in the laminar CH4/O2/N2 premixed flame by laser-induced fluorescence (LIF). The NO A-X (0,0) vibrational band around 226nm was excited using a XeCl excimer-pumped dye laser. Selecting an appropriate NO transition minimizes interference from Rayleigh scattering and O2 fluorescence. The measurements were taken in CH4/O2/N2 premixed flame with equivalence ratios varying from $1.0{\sim}1.6$, and a fixed flowrate of 5slpm. NO was found to produce primarily between an inner premixed and an outer nonpremixed flame front, and total NO concentration is raised when equivalence ratios increase. These results suggest that prompt NO is likely to contribute to NO formation in CH4/O2/N2 premixed flame. Furthermore, this trend was well matched with previous works.

  • PDF

평면 레이저 유도 형광법(PLIF)을 이용한 $CH_4/O_2N_2$ 예혼합화염의 NO 농도 분포 가시화에 관한 연구 (A Study on the Visualization of NO Concentration Distributions in $CH_4/O_2N_2$ Premixed Flames by PLIF)

  • 박경석;이세환
    • 한국분무공학회지
    • /
    • 제6권3호
    • /
    • pp.1-7
    • /
    • 2001
  • In this study, quantitative measurement of nitric oxide concentration distributions visualization were investigated in the laminar $CH_4/O_2N_2$ nixed flame by Planar laser-induced fluorescence(PLIF). The NO A-X (0,0) vibrational band around 226nm was excited using a XeCl excimer-pumped dye laser. Selecting an appropriate NO transition minimizes interference from Rayleigh scattering and $O_2$ fluorescence. The measurements were taken in $CH_4/O_2N_2$ premixed flame with equivalence ratios varying from $1.0{\sim}1.6$, and a fixed flow rate of 3slpm. NO was found to produce primarily between an inner premixed and an outer nonpremixed flame front, and total NO concentration is raised when equivalence ratios increase. These results suggest that prompt NO is likely to contribute to MO formation in $CH_4/O_2N_2$ premixed flame. Furthermore, this trend was well matched with previous works.

  • PDF