• Title/Summary/Keyword: Flame Spread

Search Result 181, Processing Time 0.026 seconds

A Study on the High-rise Apartment Balcony Plan for Egress Safety Design (고층 공동주택의 피난안전을 위한 발코니계획에 관한 연구)

  • 이용재
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.63-69
    • /
    • 2001
  • Applying a life safety concept to apartment design procedure is essential to protect people from unwanted fire. A Balcony design in apartment is a important egress safety factor because it provide means of safe egress and can limit a flame spread to adjacent space from fire source. Some design principles and details of balcony plan are suggested to improve egress safety level with analyzing broad case study.

  • PDF

A study on ignition delays of sprays using a shock tube (충격파관을 이용한 분무연료의 착화지연에 관한 연구)

  • 정진도;류정인;수곡행부
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.48-56
    • /
    • 1989
  • A shock tube technique was developed in which a freely falling droplets column produced by an ultrasonic atomizer was ignited behind reflected shock. In the present study, the effects of turbulent mixing on the ignition delay of a cetane was decided, also, ignition process was investigated. For the purpose of disturbance of droplets column and mixing, authors installed turbulent lattice in shock tube. Usually, the ignition delay is so called Arrhenius plot which found break point in the Arrhenius plot on the high temperature side. The rate of misfiring increased rapidly below 1080K, but ignition took place from 838k and luminous flame was seen to spread over the whole section by turbulent lattice. Length, from end plate to turbulent lattice, was varied with 60,40,20mm. Also, ignition process was detected by Photo transistor. As a result, it was found that physical factors changed ignition delay greatly and turbulent mixing had a considerable effects in the ignition process.

  • PDF

A Study on Low Location Lighting of Passenger Ship (여객선의 Low Location Lighting에 대한 고찰)

  • Kang, Ki-Won;Kwon, Ji-Min
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.63-66
    • /
    • 2017
  • All passenger ships aboard more than 36 passengers are to be able to easily find escape routes when the escape way by fire with flame spread were onboard vessel (incl. Ferry, Passenger, Ro-pax, Inland Ferry) It should be impossible by ordinary emergency lights. The international Maritime Organization (IMO) gives special requirement for luminescent evaluation onboard test procedure and applicable location of low location lighting. In order to maintain the residual light source for a certain time in the low location lighting with a strip-shaped light source, the light source material must be sufficiently exposed to the light due to the proper placement of the escape route. The lighting arrangement influence how maintain low location lighting strip luminescent which measured onboard in connection with what elements are mainly sustain luminescent.

  • PDF

Flow Characteristics of Fire Whirl for Different Heat Release Rate (발열량의 차이에 따른 Fire Whirl의 유동특성)

  • Bae, Sung-Yong;Sung, Kun-Hyuk;Ryou, Hong-Sun;Hong, Ki-Bae;Kim, Dong-Hyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.609-613
    • /
    • 2008
  • The fire whirl occurring by the instability of atmosphere is a rare phenomenon, but highly destructive because it has high inhalation and lift force, caused by the rotating velocity. And it is difficult to extinguish the fire, because of increment of the spread rate with the flame height. In this study, for investigation of the flow characteristic of fire whirl for various heat release rate, numerical analysis is performed in same conditions with experiments, using the FDS which is developed at NIST. For validating of the numerical study, the results are compared with the experiment. The result shows that the relation between the characteristic length and the ratio of circulation versus the buoyancy force is $z_f$/D$^{\ast}$ = 0.304(${\Omega}/{\alpha}$)^2 - 1.334${\Omega}/{\alpha}$ + 5.516.

  • PDF

A Study on the Analysis of Simulation for Fire Safety Diagnosis in Traditional Market Area (전통시장지역의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구)

  • Koo, In-Hyuk;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.46-47
    • /
    • 2017
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the traditional market area and suitability of fire risk assessment were reviewed.

  • PDF

A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea (국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구)

  • Lee, Kyu-Min;Koo, Tae-Yoon;Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF

An Analysis of False Alarm Threshold Value by Heat Detector Using Heat Release Rate (열방출률을 이용한 열감지기의 오동작 경계값 분석)

  • 홍성호;김두현
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.26-30
    • /
    • 2003
  • This paper presents a study on the analysis for false alarm of heat detector using HRR(Heat Release Rate). And it is represented to threshold value and domain of false alarm. The HRR threshold value of false alarm is calculated to use parameters obtained by small scale fire-experiment. The experiment is conducted to measure detector activation time and flame spread of wood cribs fire, etc. The results show that HRR threshold value of Fixed type detector is 20.24 kW and rate of rise type detector is 13.59 kW, respectively.

An Experimental Study on the Fire Safety Design of Windows in Building (건축물 창호의 화재안전설계를 위한 실험적 연구)

  • Lee, Byeong-Heun;Jin, Seung-Hyun;Han, Ji-Woo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.10-11
    • /
    • 2018
  • In the building, the opening penetrates the wall and serves as a spreading channel for smoke and flame in case of fire. In Korea, more than 1,500 fire plume are generated annually, and the number has increased by about 30% over the past five years. Therefore, in the case of windows protecting the opening, fire protection performance is important to prevent the spread of fire. However, in Korea, the standard for window is not clear. In this study, fire tests (EN 13823) for windows were conducted in Korea, and then fire protection performance of windows was compared. As a result of the experiment, PVC windows showed a phenomenon that they could not withstand the temperature during the fire experiment, and AL windows showed a difference in the degree of cracking of the glass.

  • PDF

A Study on Development of Korean Urban Fire Simulation (한국형 도시화재 시뮬레이션 개발에 관한 연구)

  • Koo, In-Hyuk;Yoon, Ung-Gi;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.247-248
    • /
    • 2015
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, for development of Korean Urban fire Simulation on Attenuation of Radiant Heat Flux from Water Screen.

  • PDF

Development of Phenolic SMC for The Rail (철도차량 및 지하철 불연 내장재 페놀 SMC 개발)

  • Kim Young-keun;Shin Dong-hyok;Kim Young-min;Park Joung-wuk;Min Jae-Jun
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.55-58
    • /
    • 2004
  • Phenolin resin, prepared form phenol and formaldehyde, is one of the oldest thermosetting resins available. Phenolic resins are cured via condensation polymerization with evolution of water, which in molding process is a big problem. The use of phenolic resins in glass fiber composites is growing, primarily due to their low flame spread, low smoke generation and low smoke toxicity properties. SMC of phenolics has been rearched since the 1986. The technology challenge was to match resin viscosity, handling and cure with those for the polyester SMC to avoid any special processing for fabricators and end users. Phenolic SMC was chosen because of the ease of molding to the required shape with light- weight, thin wall structure and with excellent fire protection.

  • PDF