• Title/Summary/Keyword: Flame Resistant

Search Result 82, Processing Time 0.023 seconds

Physical Properties of Lightweight Foamed Concrete with Flame Resistant EPS Waste (난연성 EPS 폐기물을 혼입한 경량기포 콘크리트의 물리적 특성)

  • Eo, Seok-Hong;Son, Ji-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.226-234
    • /
    • 2017
  • The physical properties of lightweight foamed concrete mixed with EPS waste and flame resistant EPS waste were investigated. For this purpose, the main variables considered were a cement content of 300 and $400kgf/m^3$ and an EPS replacement ratio of 0, 10, 20, 30, and 40% by the volume ratio of the foam. The water-cement ratio and the dilution concentration were fixed to 0.5 and 10% respectively. The test results showed that the apparent density meets degrees 0.5 and 0.6 of KS F4039, and they showed little difference between the two mixes of Type A and Type B, regardless of the unit cement content. The bending strength obtained through the compressive strength also met the degree of KS F 4039. The thermal conductivity was 1~3% higher for the mixes of EPS than the case of flame resistant EPS, but both mixes met the 0.4 degree of KS F4039. The absorption ratio showed the values above 20% with a 1~3% difference for the two mixes, which mean further studies will be needed to reduce the absorption ratio.

A Study on the Actual Condition of korean Firefighter's Protective Clothing (한국 소방복 실태에 관한 연구)

  • 김의경;이미식
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.1
    • /
    • pp.93-103
    • /
    • 1997
  • The purpose of this study was to investigate the actual performance of Korean firefighter's clothing through comparisons with protective clothing used in the United State, surveys of firefighter's opinion, and experiments on the material used in Korean firefighter's clothing. The paper presents experimental results as well as ways to improve current standards. The major results are as follows: 1. Korean protective clothing is too thin and too heavy. Thicker, lighter, and more heat- resistant fabric and a lighter trim should be used. 2. Korean protective clothing is not very water-resistant. A Water-resistant outershell and an innerliner which are made of air permeable and water resistant fabric must be used. 3. Korean protective clothing's outershell and innerliner should be made of fabric that is more heat-resistant, flame-resistant, and chemical resistant. 4. Protective clothing should be more brightly colored and its reflective tape should have greater reflectivity to make firefighters more visible. 5. The fastner currently used in Korean protective clothing consists of Velcro, a button, and a D-ring which can not be opened and closed quickly. A better fastener would have just velcro and a zipper. 6. The uniform for Korean firefighters consists of only a protective coat and boots. Protective trousers should be added to the standard uniform. Also, a thermal harrier should be used in winter to protect firefighters from the cold. 7. Korean firefighters should be provided with their own personal sets of protective clothing to ensure a proper fit.

  • PDF

A Study on the Afforestation of Fire-Resistant Forest through an Application of Forest Fire Investigation (산림 화재감식 응용을 통한 내화림 조성에 관한 연구)

  • Park, Young-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.118-129
    • /
    • 2011
  • In this study, species resistant to forest fire were extracted from high trees through an investigation of combustion mechanism. Here, the average flameless ignition temperatures of living leaves, branches and barks of oak were respectively, $365^{\circ}C$, $440^{\circ}C$ and $435^{\circ}C$, and the average flameless ignition temperatures of living leaves, branches, barks and cones of pine tree were respectively, $320^{\circ}C$, $405^{\circ}C$, $435^{\circ}C$ and $363^{\circ}C$. It shows that generally, pine tree has a lower flameless ignition temperature than oak and thus, has a relatively high risk of flameless ignition. When comparing risk of fire depending on ignition characteristics, Quercus serrata had a low risk of stem fire, and Quercus acutissima and Quercus serrata had a low risk of crown fire, as well. When analysing risk of fire depending on a duration of flame, also, Quercus dentata had a low risk of stem fire, and Quercus variabilis Blume had a low risk of crown fire too. Lastly, when comparing risk of fire, according to heat release rates, Quercus acutissima had a low risk of stem fire, and Quercus acutissima and Quercus dentata had a low risk of crown fire, as well. In conclusion, it was observed that as fire-resistant species, Quercus serrata and Quercus dentata have a low risk of ignition, Quercus variabilis Blume has a short duration of flame after discharging ignition when a forest fire occurs, and Quercus acutissima, Pinus Rigida and Antipathes japonica Brook have low heat release rates.

Flame Characteristics on Wall Recess Type Ceramic Combustor for Low Pollutants (Wall Recess형 저공해 세라믹 연소기의 화염특성)

  • 전영남;채재우
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.131-139
    • /
    • 1996
  • The developent of ceramic combustor is being increased beca- use of the excellent physical properties of ceramic material, that is, high-resistant strength, high emissivity power and high corrosin-resistance. Ceramic combustor has been interested in the application of ultra-lean combustion for low NO$_{x}$ emission and gaseuos waste incineration with good combustion. This experimental study was conducted to investigate the combustion and emission characteristics of wall recess type ceramic combustor with equivalence ratio, mixture flow velocity and wall recess depth as parameters. The results in this study are as follows: 1. Wall recess played a important role to extend flame stability region. 2. The peak temperature of gas was peoportional to equivalence ratio, mixture flow velocity and wall recess depth. 3. The static pressure of mixing chamber and inlet temperature depended on the position of flame zone. 4. NO reduction was achieved by lean mixture without lower combustibility.y.

  • PDF

Flame Retardance and Thermal Resistance of CPE Rubber Compound Containing a Phosphoric Ester Flame Retardant BDPDH (인산 에스테르게 난연제 BDPDH를 첨가한 CPE 고무재료의 난연성 및 내열성)

  • Park, Hyun-Ho;Lee, Chang-Seop
    • Elastomers and Composites
    • /
    • v.38 no.1
    • /
    • pp.72-80
    • /
    • 2003
  • Phosphoric ester compound was employed as thermal resistant and flame retardant for chlorinated polyethylene(CPE) rubber material which is used to prepare automotive oil cooler hose. Cure characteristics, physical properties, thermal resistance, and flame retardation of CPE rubber compounds were investigated. CPE rubber which has excellent properties such as cold resistance and chemical corrosion resistance, and is inexpensive in price than existing ethyleneacrylate rubber(EAR) was used to prepare a rubber compound useful for hose. A non-halogen flame retarding agent N,N'-bis- (diphenylphosphoro) diaminohexane(BDPDH), which is condensed phosphoric ester, was synthesized and it was mixed to CPE rubber material with the range of $0{\sim}30 phr$. From the test results, rheological properties, heat resistance, and flame retardance of CPE rubber compounds were found out to be much increased. The optimum content of BDPDH to rubber which gives maximum effect on thermal resistance and flame retardation, within the range of tolerable specification for rubber materials, was determined to be 20 phr.

Flame Resistance and Durability of Compressed Structural Wood through Microwave Heat Drying Method (마이크로파 가열건조법에 의한 압축 구조용 목재의 방염 및 내구성)

  • Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.162-170
    • /
    • 2011
  • As the result of implementing a treated material test and durability test after quickly drying S.P.F. species, a type of softwood structural material, within a short period time, soaking it in liquid phosphate flame proof agent for an hour, microwave heating it, and compressing it from 3.8cm to 1cm, when setting the appropriate heating time of microwave heating at 7 minutes at 5kW, it is observed that it satisfies the target water content (4~5%). It is shown that in a water content measurement of the wood that is compressed after being softened by soaking in the flame proof agent, drying and heating at 3kW for 9 minutes, all specimens satisfied 12~14%, the appropriate water content for exterior wood. Also, it is shown that in terms of the flame performance obtained through a flame resistance treatment of the compressed wood and a treated material test, the specimen soaked in flame proof agent for 30 minutes was the most excellent, and that the performance test result of the compressed wood in all areas, such as nail withdrawal resistance, compression, bending strength, and shearing strength, were all improved in their mechanical features to twice to three times better performances.

A Computational Study on Cooling Analysis of the Flame Deflector for the 75 tonf Class Propulsion Test Facility (75톤급 추진기관 시험설비 화염유도로 냉각해석에 관한 수치적 연구)

  • Moon, Seong-Mok;Cho, Nam-Kyung;Kim, Seong-Lyong;Jun, Sung-Bok;Lee, Kyoung-Hoon;Kim, Dong-Hwan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.55-64
    • /
    • 2015
  • In this study, a 3-D flame cooling analysis is conducted to examine thermal safety for the flame deflector of the 75 tonf class propulsion test facility, and the safe discharge of the exhaust gas is assessed by using numerical results. The Mixture multiphase model is adopted for the simulation of heat transfer and phase exchange process between flame and cooling water, and the computational study using the single species unreacted model for the exhaust plume is carried out for the flame cooling. Numerical analysis predicts maximum temperature on the flame deflector wall for different water flow rates, and evaluates the safe minimum flow rate of water corresponding to the fire-resistant temperature for concrete.

Flame Retardant and Weather Proof Characteristic of Dan-Chung Treated Wooden by Flame Retardant Performance (방염처리 방법에 따른 단청목재의 방염 및 내후특성)

  • Park, Cheul-Woo;Hong, Sang-Wan;Lee, Jong-Kyun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.2
    • /
    • pp.122-130
    • /
    • 2013
  • One of recent methods to protect wooden cultural assets from fire, there is the flame retardation which is applied directly to wood and it is to prevent fire through securing flame resistance for the material and delaying combustion when failed fire in advance and then to gain time for people in the room to evacuate and it has same goal with the Korean Fire Service Act by protecting life and property. However, in case of spraying flame retardant on the colored surface of the wooden cultural assets, there are continuous problems of decoloration, efflorescence and water absorbtion after sometime and accordingly there increases danger of damages of cultural assets. So when treating with flame retardant on wooden cultural assets, there has to be no problems on dancheong after sometime and securing sustainable methods for flmae retardation should be preceded. Accordingly, this study aims to provide basic sources for selecting proper flame retardation methods by evaluating and analyzing flame retardation capabilities according to types of flame retardants which are frequently used nowadays and spraying them on the dancheong-painted surface and confirming if there is no problem on the dancheong and wood after sometime and if flame retardation effect is sustainable with its quality and capability through precise analysis.

Thermal Characteristic Evaluation of Functionally Graded Composites for PSZ/Metal

  • Lim, Jae-Kyoo;Song, Jun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.298-305
    • /
    • 2000
  • The functionally graded material (FGM) is the new concept for a heat resisting material. FGM consists of ceramics on one side and metal on the other. A composition and microstructure of an intermediate layer change continuously from ceramics to metal at the micron level. This study is carried out to analyze the thermal shock characteristics of functionally graded PSZ/ metal composites. Heat-resistant property was evaluated by gas burner heating test using $C_2H_2/O_2$ combustion flame. The ceramic surface was heated with burner flame and the bottom surface cooled with water flow. Also, the composition profile and the thickness of the graded layer were varied to study the thermo mechanical response. Furthermore, this study carried out the thermal stress analysis to investigate the thermal characteristics by the finite element method. Acoustic emission (AE) monitoring was performed to detect the microfracture process in a thermal shock test.

  • PDF

세라믹 溶射皮膜의 强度向上에 관한 硏究

  • 김영식;배차헌;김영식
    • Journal of Welding and Joining
    • /
    • v.9 no.3
    • /
    • pp.18-25
    • /
    • 1991
  • The purpose of this paper was to investigate the effect of deposition configuration on the mechanical properties of the flame sprayed titania ceramic coating. The sprayed deposition configuration was made in different five types with titania ceramic and Ni-base alloy on the mild steel substrate. The composite coating exhibited superior mechanical properties such as hardness, adhesive strength, thermal shock resistance and corrosion resistance, whereas the mixed coating proved to be more resistant to erosion. Especially graded coating, which consist of Ni-base alloy undercost, intermediate grade coat and titania ceramic overcost, showed excellent mechanical properties.

  • PDF