• 제목/요약/키워드: Flame Front Propagation

검색결과 45건 처리시간 0.029초

0.57의 L/D 비를 가지는 폭발챔버에서 전파하는 화염과 다중 장애물의 상호작용에 관한 실험적 연구 (Experimental Studies on the Interactions between Propagating Flames and Different Multiple Obstacles in an Explosion Chamber with a L/D Ratio of 0.57)

  • 박달재
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.70-77
    • /
    • 2012
  • Experimental investigations were performed to examine the characteristics of propagating flame fronts around multiple bars within a rectangular chamber. The explosion chamber is 400 mm in height, $700{\times}700mm^2$ in cross-section and has a large top-venting area, $A_v$, of $700{\times}210mm^2$. This results in a value of 0.44 for $A_v/V^{2/3}$ and a L/D value of 0.57. The multiple obstacles of length 700 mm with a blockage ratio of 30 % were placed within the chamber. Temporally resolved flame front images were recorded by a high speed video camera to investigate the interaction between the propagating flame and the obstacles. Results showed that the flame propagation speeds before the flame impinges onto the obstacle almost equal to the laminar burning velocity. As the propagating flame impinged on the obstacle, the central region of flame began to become concave, this resulted in the flame deceleration in the region. As the flame interacted with the modified flow filed generated behind the central obstacle, the probability density functions(PDFs) of the local flame displacement speed were extensively distributed toward higher speeds.

예혼합 난류화염구조에 미치는 레이놀즈 수와 담퀠러 수의 영향에 관한 연구 (A Study on the Effects of Reynolds Number and Damkohler Number in the Structure of Premixed Turbulent Flames)

  • 김준효;안수길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.34-41
    • /
    • 1995
  • The structure of premixed tubulent flames in a constant-volume vessel was investigated using a schlieren method and microprobe method. The schlieren method was used to observe the flame structure qualitatively. The microprobe method, which detects a flamelet by detecting its flame potential signal, was used to investigate the deeper flame structure behind the flame front. The flame potential signal having one to six peaks was obtained in the case of turbulent flames, each of them being regarede as a flamelet existing in the flame zone. Based on this consideration, the flame propagation speed, the thickness of the flame zone, the number of flamelets and the separation distance between adjacent flamelets in the flame zone were measured. Moreover, the thickness of flamelet which could not be attempted in the conventional electrostatic probe method was also investigated. The experimental results of this work suggest the existence of "reactant islands" in the reaction zone, and show that the averaged number of flamelets increases with an increase in the turbulence intensity and/or a decrease in the Damkohler number. The mean thickness of flamelet in the case of turbulent flames was found to be about two times compared to laminar values.ar values.

  • PDF

국소적 정상초음파장에 의해 교란되어 사각튜브형 연소실 내에서 전파하는 메탄/공기 예혼합화염의 슐리렌기법에 의한 가시화 (A Schlieren-photographic Visualization of the Methane/Air Premixed Flame Propagating inside a Rectangular Tube Locally-perturbed by an Ultrasonic Standing Wave)

  • 김민성;김정수;황용연
    • 한국추진공학회지
    • /
    • 제18권4호
    • /
    • pp.43-49
    • /
    • 2014
  • 국소적 정상초음파장의 교란이 관내 메탄/공기 예혼합화염의 전파속도 및 화염구조에 미치는 영향을 규명하기 위한 실험적 연구를 수행하였다. 슐리렌가시화기법을 이용하여 정상초음파 유무에 따른 화염선단 발달과정의 변이를 상세히 관찰하였다. 정상초음파가 개재할 때, 기연부에서 가로방향의 줄무늬가 생성되었고, 연소반응의 촉진으로 화염의 속도는 증가하였으며, 화염의 발달과정이 부력의 영향으로부터 자유로워져 화염선단의 상하 대칭성을 유지하려는 경향을 보인다.

천연가스의 연소속도 측정에 관한 실험적 연구 (An experimental study on the burning velocity measurement of natural gas)

  • 유현석;한정옥;방효선
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.195-201
    • /
    • 1997
  • Static and non-static flame methods were used to measure the laminar burning velocity of methane, ethane and natural gas. The flame slot angle and velocity of unburned gas mixture were determined by Schlieren method and LDV, respectively, for static flame. The diameter of nozzle was selected as 11 mm. The experimental results containing the stretch effect showed that the maximum burning velocities were 41.5 for natural gas, 40.8 for methane and 43.4 cm/sec for ethane on equivalence ratio of 1.1. Constant volume combustion chamber was also used for non-static flame. The propagation process of flame front was visualized by high speed camera during constant pressure. The maximum burning velocity of natural gas was determined as 42.1 cm/sec on equivalence ratio of 1.15.

질소 희석된 부탄 부상화염에 있어서 화염진동에 관한 연구 (Study on Flame Oscillations in Laminar Lift-off Butane Flames Diluted with Nitrogen)

  • 윤성환;박정;권오붕;김정수
    • 대한기계학회논문집B
    • /
    • 제34권7호
    • /
    • pp.729-738
    • /
    • 2010
  • 질소로 희석된 부탄 층류 부상 화염에서 발생할 수 있는 화염진동 메커니즘을 살펴보기 위하여 실험적 연구를 수행하였다. 화염 진동은 층류 자유제트 부상 화염에서 5가지 영역으로 구분되었다: 화염 안정화 영역 (I), 열손실에 의한 진동 (II), 열손실에 의한 진동과 부력에 의한 진동이 혼재된 영역 (III),열손실에 의한 진동과 화염날림 직전의 진동이 혼재된 영역 (IV), 그리고 열손실에 의한 진동, 부력에 의한 진동 및 화염날림 직전의 진동이 모두 혼재된 영역(V). 각각의 화염진동의 특성을 규명하기 위해 화염의 시간에 따른 부상 높이 변화에 대한 FFT분석을 수행하였고 각 영역에 관련된 무차원 변수와 스트라훌 수의 조합으로 특성화 작업을 수행하였다.

Dynamic Sub-grid 모델을 이용한 G 방정식에 의한 보염기 주위의 난류 예혼합 연소에 관한 대 와동 모사 (Large Eddy Simulation of Turbulent Premixed Combustion Flow around Bluff Body based on the G-equation with Dynamic sub-grid model)

  • 박남섭;고상철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권8호
    • /
    • pp.1084-1093
    • /
    • 2010
  • 화염 전파 특성을 나타내는 G 방정식에 기초한 Sub-grid Scale연소 모델을 이용하여 보염기 주위의 난류 예혼합 연소 해석에 관한 대 와동 모사를 수행하였다. Dynamic SGS 모델이 G방정식에 도입되었으며, 삼각형의 보염기 배면의 예혼합 연소 유동에 의해 검증되었다. 해석결과는 실험결과와의 비교를 통해 속도와 온도분포를 잘 예측하고 있음을 확인하였다.

메탄/공기 예혼합화염의 동역학적 거동과 정상초음파의 교반 (Agitation Effects of an Ultrasonic Standing Wave on the Dynamic Behavior of Methane/Air Premixed Flame)

  • 서항석;이상신;김정수
    • 한국추진공학회지
    • /
    • 제16권3호
    • /
    • pp.16-23
    • /
    • 2012
  • 정상초음파의 교반이 메탄/공기 예혼합화염의 동역학적 거동에 미치는 영향을 규명하는 실험 결과를 본 연구에서 제시한다. 슐리렌 기법을 이용하여 전파하는 화염을 가시화하였고, 이미지 후처리를 통해 정상초음파 유무에 따른 화염선단의 전파속도를 상세히 관찰하였다. 전파속도는 이론당량비에서 정상 초음파가 교반하는 경우에 크게 증가하였으며, 당량비가 연소 상한계 혹은 연소 하한계로 벗어남에 따라 교반의 효과는 감소하였다. 정상초음파장은 화염 구조의 왜곡을 동반하고, 그 변이 형상은 교반하는 초음파장의 특성에 전적으로 종속하였다.

질소 희석된 프로판 자유제트 층류부상화염에 있어서 화염 자기진동 특성에 관한 연구 (Study of Characteristics of Self-Excitation in Lifted Laminar Free-Jet Propane Flames Diluted with Nitrogen)

  • 윤성환;박정;권오붕;배대석
    • 대한기계학회논문집B
    • /
    • 제34권4호
    • /
    • pp.399-408
    • /
    • 2010
  • 질소 희석된 프로판 층류 부상 화염에서 화염진동 불안정성과 화염 곡률 효과를 살펴보기 위하여 실험적 연구를 수행하였다. 화염 진동은 총 3가지 영역으로 열손실에 의한 진동, 열손실 및 부력이 혼재된 진동, 그리고 열손실 및 루이스 수에 의한 영향이 혼재된 진동으로 구분되었다. 순수 열손실에 의한 진동은 루이스 수에 의한 진동과 부력에 의한 수력학적 불안정성과 관련이 없으며 연료 루이스 수에 관계없이 모든 부상화염 조건에서 관찰되었다. 화염의 시간에 따른 부상높이 변화에 대한 FFT분석을 통해 화염진동 불안정성의 실험적 증거와 특성을 명확히 제시하였고, 부상 화염의 열손실에 의한 자기진동의 메커니즘에 대한 시나리오를 논의한다.

Dynamic Subgrid G-방정식을 적용한 난류 예혼합 화염의 LES 해석 (Large Eddy Simulation of Turbulent Premixed Flame Behavior with Dynamic Subgrid G-Equation Model)

  • 박남섭;김만영
    • 한국항공우주학회지
    • /
    • 제33권11호
    • /
    • pp.57-64
    • /
    • 2005
  • 화염면의 전파를 모사하는 -방정식에 기초한 DSGS 모델을 이용한 난류 예혼합 연소에 대한 LES 해석을 수행하였다. -방정식에 새롭게 도입된 DSGS 모델을 적용한 LES 지배방정식을 고찰한 후 후향계단을 갖는 복잡한 형상의 연소기 내의 난류 예혼합 연소 유동을 고찰하였다. 본 연구의 LES 해석은 재부착 위치, 평균속도 및 변동량, 그리고 온도와 같은 실험결과를 정확히 예측하였다.

난류 예혼합연소 화염의 LES 및 산업용 연소기 개발을 위한 LES 응용 해석 기술 (LES OF TURBULENT PREMIXED COMBUSTION FLAME AND LES APPLICATION FOR THE INDUSTRIAL COMBUSTOR DEVELOPMENT)

  • 박남석;류종력
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.437-441
    • /
    • 2010
  • LES results of turbulent premixed combustion flows are introduced by using the dynamic sub-grid scale model based on G-equation describing the flame front propagation. The turbulent premixed combustion flows around bluff body and over backward facing step are analyzed to validate present formation. LES of swirling partially premixed combustion flame is also performed to conform the predictive capabilities of LES model and to prompt our understanding for the combustion flows over double cone swirl burner combustor by using CFD-ACE+ commercial code.

  • PDF