• Title/Summary/Keyword: Flame Detection

Search Result 197, Processing Time 0.027 seconds

Determination of Cadmium(II) and Copper(II) by Flame Atomic Absorption Spectrometry after Preconcentration on Column with Pulverized Amberlite XAD-4 with Bismuthiol I

  • Park, Dong-Seok;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.8
    • /
    • pp.1375-1382
    • /
    • 2007
  • A column preconcentration method with pulverized Amberlite XAD-4 loaded with bismuthiol I (BI) has been developed for the determination of trace Cd(II) and Cu(II) in various real samples by flame atomic absorption spectrophotometry. Various experimental conditions, such as the size of XAD-4, adsorption flow rate, amount of bismuthiol I, stirring time for adsorbing bismuthiol I on XAD-4, pH of sample solution, amount of XAD-4- BI, desorption solvent, and desorption flow rate, were optimized. Also, the adsorption capacity and the adsorption rate of Cd(II) and Cu(II) on XAD-4-BI were investigated. The interfering effects of various concomitant ions were investigated, Bi(III), Sn(II) and Fe(III) were found to affect the determination. But the interference by these ions was completely eliminated by adjusting the amount of XAD-4-BI resin to 0.70 g, although the adsorption flow rate was slower. For Cd(II) our proposed technique obtained a dynamic range of 0.5-40 ng mL-1, a correlation coefficient (R2) of 0.9913, and a detection limit of 0.3 ng mL-1. For Cu(II), the corresponding values were 2.0-120 ng mL-1, 0.9921 and 1.02 ng mL-1. To validate this proposed technique, the aqueous samples (stream water, reservoir water, tap water and wastewater), the diluted brass sample and the plastic sample, as real samples, were used. Recovery yields of 91-103% were obtained. These measured data were not different from ICP-MS data at 95% confidence level. Our proposed method was also validated using rice flour CRM (normal, fortified) samples. From the results of our experiment, we found that the technique we present here can be applied to the determination of Cd(II) and Cu(II) in various real samples.

Preconcentration, Separation and Determination of lead(II) with Methyl Thymol Blue Adsorbed on Activated Carbon Using Flame Atomic Absorption Spectrometry (불꽃원자 흡수 분광법으로 활성탄소에 흡착된 메틸티몰 블루로 납(II)의 예비농축, 분리 및 측정)

  • Ensafi, Ali A.;Ghaderi , Ali R.
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • on-line system for preconcentration and separation of lead(II) is presented. The method is based on the complex formation of Pb(II) with adsorbed Methyl thymol blue on activated carbon. The conditions of preparing the solid phase reagent and of quantitative recovery of Pb(II) from diluted solutions, such as acidity of aqueous phase, solid phase capacity, and flow variables were studied as well as effect of potential interfering ions. After preconcentration step, the metal ions are eluted automatically by 5 ml of 0.5 M HNO3 solution and the lead ions content was determined by flame atomic absorption spectrometry. Under the optimum conditions, the lead ions in aqueous samples were separated and preconcentrated about 1000-fold by the column. The detection limit was 0.001 g mL-1. Lead has been determined in river and tap water samples, with recovery of 98 to 102%.

Ag-functionalized SnO2 Nanowires Based Sensor for NO2 Detection at Low Operating Temperature (NO2 감응을 위한 Ag 금속입자가 기능화된 SnO2 나노선 기반 저온동작 센서)

  • Choi, Myung Sik;Kim, Min Young;Ahn, Jihye;Choi, Seung Joon;Lee, Kyu Hyoung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.2
    • /
    • pp.11-17
    • /
    • 2020
  • In this study, Ag-functionalized SnO2 nanowires are presented for NO2 gas sensitive sensors at low temperatures (50℃). SnO2 nanowires were synthesized using vapor-liquid-solid method, and Ag metal particles were functionalized on the surface of SnO2 nanowires using flame chemical vapor deposition method. As a result of the sensing test about Ag-functionalized SnO2 nanowires based sensor, the response (Rg/Ra) to 10 ppm NO2 was 1.252 at 50℃. We believe that metal-functionalizing is a one of good way to increase the feasibility about semiconductor gas sensor.

Laser-induced plasma emission spectra of halogens in the helium gas flow and pulsed jet (헬륨 가스 플로우와 가스 펄스 젯에서 할로겐족 원소들의 레이저유도 플라즈마 방출 스펙트럼)

  • Lee, Yonghoon;Choi, Daewoong;Gong, Yongdeuk;Nam, Sang-Ho;Nah, Changwoon
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.235-244
    • /
    • 2013
  • Detection of halogens using laser-induced breakdown spectroscopy (LIBS) in open air is very difficult since their strong atomic emission lines are located in VUV region. In NIR region, there are other emission lines of halogens through electronic transitions between excited states. However, these lines undergo Stark broadening severely. We report the observation of the emission lines of halogens in laser-induced plasma (LIP) spectra in NIR region using a helium gas flow. Particularly, the emission lines of iodine at 804.374 and 905.833 nm from LIPs have been observed for the first time. In the helium ambient gas, Stark broadening of the emission lines and background continuum emission could be suppressed significantly. Variations of the line intensity, plasma temperature, and electron density with the helium flow rate was investigated. Detection of chlorine and bromine in flame retardant of rubbers was demonstrated using this method. Finally, we suggest a pulsed helium gas jet as a practical and ecomonical helium gas source for the LIBS analysis of halogens in open air.

Measurement conditions for cadmium in urine by flame atomic absorption spectrophotometry (불꽃원자 흡수광법에 의한요중 카드뮴 배설량 측정의 지적조건)

  • Choi, Ho-Chun;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.269-279
    • /
    • 1984
  • The optimum conditions for measuring cadmium content of less than 0.2ppm by flame atomic absorption spectrophotometry were investigated. The cadmium in urine was extracted by APDC-MIBK for the analysis by atomic absorption spectrophotometry after ashing them by a wet method. 1. Optimum conditions by APDC-MIBK and DDTC-MIBK extractions. The acidic aqueous solution was prepared with appropriate amount of 0.IN nitric acid, 5ml of 25% (W/V) sodium potasstum tartarate, 10ml of saturated ammonium sulfate, and 2ml of 2% APDC(or 1 ml of 5% DDTC) chelating agent. The total volume of solution was adjusted to 55 ml and pH to $2{\sim}10$ (or$7{\sim}10$). The aqueous solution was extracted with 10ml MIBK. Concentration of Triton X-100 did not effect the absorbance for APDC-MIBK extraction of cadmium, but absorbance decreased as the concentration increased for DDTC-MIBK extraction. The sensitivity and detection limits for the cadmium determination from APDC-MIBK extraction were 0.0038ppm and 0.0102, 0.0022ppm and 0.0116 for DDTC-MIBK, and 0.0132ppm and 0.0034 for 0.1N nitric acid. APDC-MIBK and DDTC-MIBK extractions were 3 times higher than 0.1N nitric acid for the sensitivity. 2. Excretion of cadmium in 24-hour urine by APDC-MIBK extraction. Determination of cadmium in urine by atomic absorption spectrophotometry of A.A. (Cd=2 mA) mode and B.C. (Cd=4 mA) mode and B.C. (Cd=4mA, $D_2=20mA$) mode showed some difference (p<0.05). The difference of cadmium determination and recovery according to method of standard additions and standard calibration curve method in urine was not significant (p>0.05, $93.48{\pm}11.78%,\;94.83{\pm}22.00%$). Excretion of cadmium in 24-hour urine collection from normal person and variance analysis within measurement variation was not significant (p>0.05), but between interindividual was significant (0.05). Determination of cadmium content by two different methods of flame atomic absorption spectrophotometry and dithizone colorimetry showed that the results from the two methods can be described by a regression line with a good correlation (y=1.0153x-0.2927, x=Cd by D.C., y=Cd by A.A.S., $r=0.8651^*$, p<0.01).

  • PDF

Analysis of Butyltin Compounds(mono-, di-, and tributyltin) in Human Blood (혈액 중의 주석화합물(MBT, DBT, TBT)의 분석과 농도에 관한 연구)

  • Kim, Nam Sook;Park, Dong Uk;Oh, Jae Ryoung;Shim, Woon Joon
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.115-122
    • /
    • 2001
  • Butyltin compounds, including mono-(MBT), di-(DBT) and tributyltin(TBT) were analyzed in 44 human blood samples randomly collected from a hospital in "K" a city. Gas chromatograph equipped with flame photometric detector(FPD) was used to quantify the amounts of butylin compounds. Method detection limits(MDL) of this analytical method were 3.69ng Sn/g for MBT, 0.91ng Sn/g for DBT and 1.09ng Sn/g wet wt for TBT respectively. Standard reference material(SRM) containing of $1.3{\mu}g/g$ TBT as chloride was analyzed to check if this analytical results would be reliable. Recovery of about 90% was obtained through this analysis, indicating that the analytical method from butyltin compounds blood was reliable. The concentrations of butyltin compounds ranged MDL(<3.69) to 7.93ng Sn/g for MBT and 1.15 to 5.41ng Sn/g wet wt for DBT. Tributyltin was below detection limit in all samples. Detection limits of our results are lower than those reported by Kannan et al. who reported butyltin compounds in 33 human blood samples in the United States. Detection of MBT and DBT on blood sample implies that butyltin compounds could be absorbed through consumption of seafoods or exposure to food stuffs made of plastics and household items. Further study is needed to examine if butyltin compounds in blood can be reliably analyzed and used as intake index.

  • PDF

Changes in the gas chromatographic sensitivity with its analytical setting: Comparison of TDU and loop-injection system for the analysis of sulfur compounds (GC 분석 시스템의 설정과 그에 따른 감도의 차이: 열탈착 방식 대비 루프주입방식에 의한 황성분의 분석)

  • Kim, Ki-Hyun;Choi, Y.J.;Kim, S.C.
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.66-73
    • /
    • 2005
  • In this study, we investigated the gas chromatography (GC) and pulsed flame photometric detection (PFPD) system for the analysis of four major reduced S compounds including hydrogen sulfide ($H_2S$); methyl mercaptan ($CH_3SH$); dimethyl sulfide (DMS); and dimethyl disulfide (DMDS) contained in environmental samples. To analyze these compounds in high concentration range (above ppb level), we developed a high mode analytical setting with the loop-injection system. By contrast, we also established a low mode setting for the analysis of low concentration samples (ppt-level samples from ambient air) by the combination with thermal desorption unit (TDU). Comparative analysis of both settings revealed that relative detection properties of four S compounds are systematic enough. The results of high mode analysis indicated that the patterns were systematic among S compounds: $H_2S$ exhibited the lowest sensitivity, while DMDS showed the strongest one. The results were also compared in terms of sensitivity reductions for all compounds by dividing slope ratios between low and high mode system. Although low mode system exhibited significant reductions on the order of a few tens times, their detection characteristics were highly consistent as it was shown in the high mode setting. To learn more about absolute and relative relations between two different modes of S analysis, future studies may have to be directed to cover more complicated nature of GC/PFPD performance.

Electronic Nose Analysis of Ethanol in Gochujang for Halal Food Certification (전자코를 사용하여 할랄식품 적용을 위한 고추장 중 에탄올 분석)

  • Park, Su Won;Sim, You Sin;Choi, Jin Young;Park, Eun Young;Noh, Bong Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.193-200
    • /
    • 2016
  • The purpose of this study was to investigate whether the electronic nose can be applied as a primary screening procedure to detect ethanol in gochujang for halal certification. First, ethanol content in 25 traditional gochujang was measured by gas chromatography with flame ion detector, widely accepted as the conventional method of alcohol detection. The content ranged from 0.14 to 2.7%. Then, 8 gochujangs selected from among the initial 25 samples were analyzed by electronic nose. Similar ethanol content patterns were observed between the two detection methods. In addition, commercial gochujang products were examined by electronic nose to ensure that they complied with the required ethanol standard of the halal certification authority. Consequently, it was confirmed that electronic nose analysis can be applied as a primary screening method for halal certification.

Wild Fire Monitoring System using the Image Matching (영상 접합을 이용한 산불 감시 시스템)

  • Lee, Seung-Hee;Shin, Bum-Joo;Song, Bok-Deuk;An, Sun-Joung;Kim, Jin-Dong;Lee, Hak-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.40-47
    • /
    • 2013
  • In case of wild fire, early detection of wild fire is the most important factor in minimizing the damages. In this paper, we suggest an effective system that detects wild fire using a panoramic image from a single camera with PAN/TILT head. This enables the system to detect the size and the location of the fire in the early stages. After converting RGB image input to color YCrCb image, the differential image is used to detect changes in movement of the smoke to determine the regions which may be prone to forest fire. Histogram analysis of fire flame is used to determine the possibility of fire in the predetermined regions. In addition, image matching and SURF were used to create the panoramic image. There are many advantages in this system. First of all, it is very economical because this system needs only a single camera and a monitor. Second, it shows the live image of wide view through panoramic image. Third, this system can reduce the quantity of saved data by storing panoramic images.

Measurement of Spatial Traffic Information by Image Processing (영상처리를 이용한 공간 교통정보 측정)

  • 권영탁;소영성
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.28-38
    • /
    • 2001
  • Traffic information can be broadly categorized into point information and spatial information. Point information can be obtained by chocking only the presence of vehicles at prespecified points(small area), whereas spatial information can be obtained by monitoring large area of traffic scene. To obtain spatial information by image processing, we need to track vehicles in the whole area of traffic scene. Image detector system based on global tracking consists of video input, vehicle detection, vehicle tracking, and traffic information measurement. For video input, conventional approaches used auto iris which is very poor in adaptation for sudden brightness change. Conventional methods for background generation do not yield good results in intersections with heave traffic and most of the early studies measure only point information. In this paper, we propose user-controlled iris method to remedy the deficiency of auto iris and design flame difference-based background generation method which performs far better in complicated intersections. We also propose measurement method for spatial traffic information such as interval volume/lime/velocity, queue length, and turning/forward traffic flow. We obtain measurement accuracy of 95%∼100% when applying above mentioned new methods.

  • PDF