• 제목/요약/키워드: Fixed-speed wind turbine

검색결과 37건 처리시간 0.031초

PSCAD/EMTDC를 이용한 고정속 풍력발전시스템 모델링 및 과도상태 안정화기법 (Fixed speed wind power generation system modeling and transient state stabilization method using PSCAD/EMTDC)

  • 김영주;박대진;;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1178-1179
    • /
    • 2008
  • This paper describes a modeling of fixed speed wind power generation system which comprise of wind turbine, generator and grid. The wind turbine is based on MOD-2, which is IEEE standard wind turbine, and includes a component using wind turbine characteristic equation. Fixed speed induction generator is directly connected to grid, so the variation of wind speed has effects on the electrical torque and electrical output power. Therefore the power control mode pitch control system is necessary for aerodynamic control of the blades. But the power control mode does not operate at the fault condition. So it is required some methods to control the rotor speed at transient state for stabilization of wind power system. In this paper, simulation model of a fixed speed wind power generation system based on the PSCAD/EMTDC is presented and implemented under the real weather conditions. Also, a new pitch control system is proposed to stabilize the wind power system at the fault condition. The validity of the stabilization method is demonstrated with the results produced through sets of simulation.

  • PDF

이중여자 유도발전기를 이용한 가변속운전과 정속운전 풍력발전시스템의 운전특성 비교 (Comparison of Characteristics for Variable Operation using Doubly-fed Induction Generator and Fixed Speed Operation in Wind Turbine System)

  • 노경수;김태호
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1313-1320
    • /
    • 2009
  • This paper analyzes the steady-state operating characteristics of doubly-fed induction generator(DFIG) and fixed-speed induction generator(FSIG) in wind turbine system. It also presents a modeling and simulation of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink, and compares the responses between DFIG and FSIG wind turbine systems with respect to wind speed variation, 3-phase fault and 1-phase ground fault of the network. Simulation results show the variations of generator's active/reactive output, rotor speed, terminal voltage, fault current, etc. Case studies demonstrate that DFIG illustrates better performance compared to FSIG.

Wind Turbine Simulator for Comparative Study of MPPT Controls

  • Putri, Adinda Ihsani;Ahn, Minho;Choi, Jaeho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.128-129
    • /
    • 2012
  • This paper proposed the wind turbine simulator for comparative study of the MPPT controls. The development of this wind turbine simulator is based on the torque controlled induction motor. The torque reference is obtained from a mathematical model of wind turbine whereas the inputs are rotor speed, wind speed and fixed-value of pitch angle. By using this wind turbine simulator, the real wind is not needed. Wind speed information can be stored and regenerated anytime. Hence it is possible to apply the same wind speed condition to different MPPT controls. With the same wind speed condition, it can fairly compare the advantages and disadvantages of the MPPT controls. The proposed wind turbine simulator is verified through PSIM simulation.

  • PDF

The wind tunnel measuring methods for wind turbine rotor blades

  • Vardar, Ali;Eker, Bulent
    • Wind and Structures
    • /
    • 제7권5호
    • /
    • pp.305-316
    • /
    • 2004
  • In this study, a wind tunnel, that has been developed for experiments of wind turbine rotor blades, has been considered. The deviations of the measurements have been examined after this wind tunnel had been introduced and the measurements on it had been explained. Two different wind turbine rotor blades miniatures have been used for getting better results from the experiments. The accuracy of measurements have been experimented three times repetitively and examined statistically. As a result, wind speed values which this type of wind tunnel and wind turbine rotors need for starting, wind speed in the tunnel, temperature and moisture values, the number of rotor's revolution, and the voltage that is produced in 102 ${\Omega}$ resistance and current values have been determined to be fixed by measurements used. This type of wind tunnel and wind turbine rotor' performance difference and the difference of revolution figures have been determined to be fixed by measurements used.

5MW급 풍력 터빈의 공력 및 제어 특성에 관한 연구 (Study on the Aerodynamics and Control Characteristics of 5 MW Wind Turbine)

  • 타이펑주;강기원;이장호
    • 신재생에너지
    • /
    • 제7권2호
    • /
    • pp.59-69
    • /
    • 2011
  • 5MW wind turbine is regarded as a promising system for offshore wind farms in the western sea of Korean. And the wind turbine is developed in many companies but not much information is known about it. In this study, aerodynamics and control characteristics depending on several control methods is reviewed on 5MW wind turbine, in which configuration data of the turbine are used from the previous study of NREL. For the calculations, GH_Bladed, which is certificated software by GL, is used and compared with data from FAST code of NREL. This study shows that how much power production, and aerodynamic performances and loads can be obtained with different controls in the operation of 5MW wind turbine, which is expected to be useful in the design of the wind turbine system.

Voltage Impacts of a Variable Speed Wind Turbine on Distribution Networks

  • Kim, Seul-Ki;Kim, Eung-Sang
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.206-213
    • /
    • 2003
  • The main purpose of this paper is to present a simulation model for assessing the impacts of a variable speed wind turbine (VSWT) on the distribution network and perform a simulation analysis of voltage profiles along the wind turbine installed feeder using the presented model. The modeled wind energy conversion system consists of a fixed pitch wind turbine, a synchronous generator, a rectifier and a voltage source inverter (VSI). Detailed study on the voltage impacts of a variable speed wind turbine is conducted in terms of steady state and dynamic behaviors. Various capacities and different modes of variable speed wind turbines are simulated and investigated. Case studies demonstrate how feeder voltages are influenced by capacity and control modes of wind turbines and changes in wind speed under different network conditions. Modeling and simulation analysis is based on PSCAD/EMTDC a software package.

칼만필터 및 인공신경망에 기반한 가변속 풍력발전 시스템을 위한 비선형 제어기 설계 (Design of Nonlinear Controller for Variable Speed Wind Turbines based on Kalman Filter and Artificial Neural Network)

  • 문대선;김성호
    • 한국지능시스템학회논문지
    • /
    • 제20권2호
    • /
    • pp.243-250
    • /
    • 2010
  • 최근 풍력발전 시스템은 가장 빨리 발전하고 있는 신재생 에너지원중 하나로 각광을 받고 있으며, 풍력발전 시스템의 주된 관심사는 어떻게 광범위한 풍속의 변화에서도 효율적으로 시스템을 동작시키는 가에 있다. 가변속 풍력발전 시스템은 고정속 풍력발전 시스템에 비해 더 높은 에너지 효율, 낮은 컴포넌트 스트레스를 달성할 수 있다는 장점을 갖는다. 일반적으로 가변속 풍력발전 시스템의 제어를 위해서는 풍속정보의 취득이 필수적으로 요구된다. 하지만 풍속계 등에 의해 측정된 풍속은 여러 요인에 의해 정확하지 않다는 문제점을 갖는다. 이에 본 연구에서는 풍속의 추정을 위한 칼만 필터와 칼만 필터에 의해 추정된 정보를 사용하여 학습된 인공신경망으로부터 최적의 로터 회전 속도를 유추할 수 있는 새로운 형태의 가변속 풍력발전 시스템을 위한 제어 알고리듬을 제안하고자 한다. 또한 Matlab의 시뮬링크를 사용하여 다양한 시뮬레이션 수행하여 제안된 기법의 유용성을 확인하고자 한다.

연계선로의 조건 변화에 따른 DFIG와 FSIG 풍력발전시스템의 운전특성 비교 (Comparison of Operating Characteristics for DFIG and FSIG wind Turbine Systems with Respect to Variable Interconnecting Line Conditions)

  • 노경수;김태호
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.8-15
    • /
    • 2010
  • This paper analyzes the steady-state output characteristics of variable-speed wind turbine systems using doubly-fed induction generators(DFIG) compared with fixed-speed induction generator(FSIG) wind turbine systems. It also presents simulations of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink and compares the responses between DFIG and FSIG wind turbine systems with respect to wind speed variation, impedance changes and X/R ratio changes of interconnecting circuits. Simulation results show the variation of generator's active output, terminal voltage and fault currents at the interconnecting point. Case studies demonstrate that DFIG wind turbine systems illustrate better performance to 3-phase fault than FSIG's.

Numerical investigation on effects of rotor control strategy and wind data on optimal wind turbine blade shape

  • Yi, Jin-Hak;Yoon, Gil-Lim;Li, Ye
    • Wind and Structures
    • /
    • 제18권2호
    • /
    • pp.195-213
    • /
    • 2014
  • Recently, the horizontal axis rotor performance optimizer (HARP_Opt) tool was developed in the National Renewable Energy Laboratory, USA. This innovative tool is becoming more popular in the wind turbine industry and in the field of academic research. HARP_Optwas developed on the basis of two fundamental modules, namely, WT_Perf, a performance evaluator computer code using the blade element momentum theory; and a genetic algorithm module, which is used as an optimizer. A pattern search algorithm was more recently incorporated to enhance the optimization capability, especially the calculation time and consistency of the solutions. The blade optimization is an aspect that is highly dependent on experience and requires significant consideration on rotor control strategies, wind data, and generator type. In this study, the effects of rotor control strategies including fixed speed and fixed pitch, variable speed and fixed pitch, fixed speed and variable pitch, and variable speed and variable pitch algorithms on optimal blade shapes and rotor performance are investigated using optimized blade designs. The effects of environmental wind data and the objective functions used for optimization are also quantitatively evaluated using the HARP_Opt tool. Performance indices such as annual energy production, thrust, torque, and roof-flap moment forces are compared.

Flicker Measurement based on SVR for Fixed-Speed Wind Generator Systems

  • ;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.117-119
    • /
    • 2009
  • This paper presents a simulation model based on support vector regression (SVR) for flicker emission estimation from wind turbines. Training patterns are developed by varying the wind speed and network parameters that might affect the expected flicker levels. A comparison is done to the fixed speed wind turbine (WT), which leads to a conclusion that the factors mentioned above have different influences on flicker emission. The simulation results have shown that the flicker estimation is performed accurately.

  • PDF