• 제목/요약/키워드: Fixed appliance

검색결과 121건 처리시간 0.037초

A NOVEL ZVS-PWM QUASI-RESONANT INVERTER WITH ACTIVE VOLTAGE-CLAMPED CAPACITOR FOR HIGH-FREQUENCY INDU-HEATED APPLIANCE

  • K.Izaki;I.Hirota;H.Yamashita;H.Omori;K.Matsumoto;K.Nishida;J.M.Sun;Na, M.kaoka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.1047-1050
    • /
    • 1998
  • This paper describes an advanced prototype of voltage-fed zero voltage soft-switching PWM resonant inverter with an active voltage clamped capacitor, which is put into practice for high-frequency high-power induction-heated appliances. This application-specific quasi-resonant inverter using the latest generation IGBTs for soft-switching can regulate its output power under a principle of a fixed frequency ZVS-PWM strategy. Its operating principle and unique features are presented as compared with a conventional quasi-resonant ZVS inverter for induction-heated cooker, together with its power regulation characteristics on the basis of its simulation and experimental results. The steady-state performances of this inverter developed for multi-burner type induction-heated food cooking appliance are evaluated and discussed from a practical point of view.

  • PDF

An esthetic appliance for the management of crown-root fracture: a case report

  • Jeon, Sang-Min;Lee, Kang-Hee;Jung, Bock-Young
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.226-229
    • /
    • 2014
  • Orthodontic extrusion is usually performed by means of a fixed orthodontic appliance that utilizes arch wire attached to adjacent teeth and transfers the desired force by elastic from the wire to the root. However, clinicians often encounter cases where the bonding required for tooth traction is not possible because the adjacent teeth have been restored with ceramic or veneer. The purpose of this case report is to describe a modified orthodontic extrusion appliance that is useful when conventional orthodontic treatment is not possible. The modified appliance was fabricated using an artificial tooth, clear plastic sheeting, and a braided fiber-reinforced composite strip that covered adjacent teeth without bonding. It satisfied the esthetic and functional needs of the patient and established the optimal biologic width.

LCC인버터를 이용한 초고주파 수술기 개발 (Development of ultra high frequency Surgery machine using LCC Inverter)

  • 김상효;이준탁;이오걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2328-2330
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows. Therefore this treatise developed electricity living body formation operation appliance by home production. Ultra high frequency eruption circuit used LC circuit, and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current.

  • PDF

LC 직렬공진에 의한 전기 수술기 개발 (Development of electric surgical machine by LC series resonance)

  • 이오걸;김태우;송호신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.153-157
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows, Therefore, this treatise developed electricity living body formation operation appliance by home production, Ultra high frequency eruption circuit used LC circuit, and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

직렬공진에 의한 피부 수술기 개발 (Development of skin surgical machine by series resonance method)

  • 이오걸;김상주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.127-132
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows. Therefore, this treatise developed electricity living body formation operation appliance by home production. Ultra high frequency eruption circuit used LC circuit. and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

Frog appliance를 이용한 상악 대구치의 원심 이동: 증례 보고 (The frog appliance for upper molar distalization: a case report)

  • Bayram, Mehmet;Nor, Metin;Kilkis, Dogan
    • 대한치과교정학회지
    • /
    • 제40권1호
    • /
    • pp.50-60
    • /
    • 2010
  • 본고의 목적은 2급 1류 치열안면 구조를 가지는 한 환자에 적용된 새로이 고안된 상악 대구치 원심 이동 장치인 Frog appliance의 효과를 평가하기 위함이다. 11세의 여자 환자가 교정 치료를 위해 본 진료실로 의뢰되었다. 환자는 미약한 2급 골격관계와 2급의 대구치 및 견치 관계를 양측 모두에서 보이고 있었다. 고정성 장치 치료를 통해 양측 상악 제1대구치를 원심 이동시키는 방법을 포함하는 치료 계획을 수립하였으며 상악 대구치를 원심 이동하기 위해 새로이 고안된 Frog appliance를 제작 및 적용하였다. 측모 두부방사선 사진으로 치료 결과를 평가하였으며 상악 제1대구치의 원심 이동이 4개월의 치료 기간 동안 이루어 졌고 1급의 구치 관계가 얻어졌다. 총 치료 기간은 16개월이 소요되었다. 두부방사선 사진을 평가한 결과 약간의 고정원 상실과 함께 대구치의 원심 이동이 치축 이동에 가깝게 일어난 것을 확인하였다. 결론적으로 Frog appliance는 환자의 협조를 요하지 않는 장치로서 간단하고 효과적으로 양측 대구치의 원심이동을 이룰 수 있는 구내 장치이다.

성장기 하악골 열성장 환자의 Berlin standard activator를 이용한 부정교합 치료: 증례보고 (Berlin standard activator in the treatment of growing patients with mandibular deficiency: Case report)

  • 이승엽
    • 대한치과의사협회지
    • /
    • 제48권11호
    • /
    • pp.819-828
    • /
    • 2010
  • Activator is a removable functional appliance used for correcting the skeletal Class II malocclusion in children with the mandibular deficiency. Berlin standard activator modified from Andresen activator has following characters; do not cover the palatal surface for tongue space, relief on lingual surface of mandibular incisors and resin capping 1/3-1/2 of crown height on mandibular incisors for preventing labioversion of mandibular incisors, L-hook between maxillary lateral incisor and canine for anterior high pull headgear, relief on mandibular posterior bite block for differential eruption of posterior teeth. Two cases presented here had a mandibular deficiency and slight maxillary protrusion. First case (an 11-year-old girl) treated with Berlin standard activator and anterior high pull headgear for 13 months followed by fixed orthodontic appliance for another 29 months. Second case (a 12-year-old boy) treated with Berlin standard activator for 6 months followed by fixed appliance for another 24 months. Treatment results showed a significant improvement in sagittal skeletal and occlusal relationship without premolar extraction. Mandibular condyles were concentric in TMJ [ossa, and masticatory muscle activities were normalized after treatment. In the retention period facial harmony and occlusal stability was maintained.

Chlorhexidine varnish 처치 후 고정식 교정장치 장착 환자의 치태내 균주 변화 양상에 대한 장기간 관찰 연구 (Long-term effects of chlorhexidine varnish treatment on microbial changes of dental plaque in orthodontic patients with fixed appliances)

  • 장영일;양윈식;남동석;김태우;백승학
    • 대한치과교정학회지
    • /
    • 제30권3호
    • /
    • pp.335-342
    • /
    • 2000
  • 본 연구의 목적은 chlorhexidine varnish를 고정식 교정장치 장착 환자의 치면에 도포한 후 나타나는 치태내 균주의 변화 양상을 장기간 관찰하는 것이다. 서울대학교병원 치과진료부 교정과에서 고정치 교정장치로 치료하기로 하였던 환자 100명중에서 32주까지 장기간 추적 (follow-up) 되었던 21명을 최종 연구대상으로 선정하였다. 실험군 (12명) 은 chlorhexidine varnish를 1주일 간격으로 4회 도포한 후 고정식 교정장치를 부착하였고, 대조군 (9명) chlorhexidine varnish 처치를 하지 않고 고정식 교정장치를 부착하였다. 그리고 실험군에서는 20주 째에 chlorhexidine varnish를 1회 처치하였다. 두 군에서 고정식 교정장치 부착 직전과 부착 후 4, 8, 20, 32주의 치태내 균주의 변화 양상을 간접면역 형광 현미경법으로 분석하고 SAS 통계프로그램을 사용하여 다음과 같은 결과를 얻었다. 1. Streptococcus mutans는 실험군에서 전 실험기간동안 통계학적으로 유의성 있게 억제되 었고 (p<0.01), 대조군에서 전 실험기간동안 통계학적으로 유의성 있게 증가하였다 (p<0.05). 2. Streptococcus sanguis, Streptococcus mitis, Actinomyces viscosus, Actinomyces naeslundii는 실험군과 대조군에서 통계학적으로 유의성 있는 변화를 보이지 않았다. 따라서 고정식 교정장치를 사용할 환자에서 chlorhexidine varnish를 처치할 경우 치아 우식의 주 원인균인 Streptococcus mutant를 장기간 선택적으로 억제할 수 있을 것으로 생각된다.

  • PDF

고정성 교정장치 장착환자의 치주질환관련 지식 및 구강건강관련 행태 (Periodontal disease-related recognition and oral health-related behavior in orthodontic patients with fixed appliance)

  • 최경선;문상은;김윤정;김선영;조혜은;강현주
    • 한국치위생학회지
    • /
    • 제17권5호
    • /
    • pp.747-755
    • /
    • 2017
  • Objectives: The purpose of study is to investigate periodontal disease-related recognition and oral health-related behavior in orthodontic patients with fixed appliance. Methods: A self-reported questionnaire was completed by 286 orthodontic patients with fixed appliance in Gwangju, Jeonnam from September 1 to September 27, 2016. The questionnaire consisted of general characteristics (3 items), orthodontic related characteristics (3 items), knowledge of periodontal disease (3 items), and oral health-related behavior (4 items). The data were analyzed by frequency analysis, percentage and chi-square analysis using SPSS 21.0 program. Results: 62.8% had experiences of dental treatment and 67.5% had intention of involvement on incremental care program in orthodontic treatment periods. Accuracy rate of cause about periodontal disease was high in female and case of acquiring information experiences on periodontal disease (p<0.05). 67.2% performed correct toothbrushing for the management of periodontal disease in the experiences of acquiring information on periodontal disease in orthodontic treatment periods (p<0.05). The proportions of using interdental toothbrush and mouth rinsing solutions were high among those over 20 years old and students in the subjects (p<0.05). Conclusions:The accuracy rate were high in the answers about cause and management of periodontal disease in case of acquiring information experiences on periodontal disease in orthodontic treatment periods. Therefore, there is a need to further development and implementation of dental hygiene intervention program for periodontal disease care with fixed orthodontic appliances in that regard.

Maxillary molar derotation and distalization by using a nickel-titanium wire fabricated on a setup model

  • Jung, Jong Moon;Wi, Young Joo;Koo, Hyun Mo;Kim, Min Ji;Chun, Youn Sic
    • 대한치과교정학회지
    • /
    • 제47권4호
    • /
    • pp.268-274
    • /
    • 2017
  • The purpose of this article is to introduce a simple appliance that uses a setup model and a nickel-titanium (Ni-Ti) wire for correcting the mesial rotation and drift of the permanent maxillary first molar. The technique involves bonding a Ni-Ti wire to the proper position of the target tooth on a setup model, followed by the fabrication of the transfer cap for indirect bonding and its transfer to the patient's teeth. This appliance causes less discomfort and provides better oral hygiene for the patients than do conventional appliances such as the bracket, pendulum, and distal jet. The treatment time is also shorter with the new appliance than with full-fixed appliances. Moreover, the applicability of the new appliance can be expanded to many cases by using screws or splinting with adjacent teeth to improve anchorage.