• Title/Summary/Keyword: Fixed appliance

Search Result 121, Processing Time 0.032 seconds

A NOVEL ZVS-PWM QUASI-RESONANT INVERTER WITH ACTIVE VOLTAGE-CLAMPED CAPACITOR FOR HIGH-FREQUENCY INDU-HEATED APPLIANCE

  • K.Izaki;I.Hirota;H.Yamashita;H.Omori;K.Matsumoto;K.Nishida;J.M.Sun;Na, M.kaoka
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1047-1050
    • /
    • 1998
  • This paper describes an advanced prototype of voltage-fed zero voltage soft-switching PWM resonant inverter with an active voltage clamped capacitor, which is put into practice for high-frequency high-power induction-heated appliances. This application-specific quasi-resonant inverter using the latest generation IGBTs for soft-switching can regulate its output power under a principle of a fixed frequency ZVS-PWM strategy. Its operating principle and unique features are presented as compared with a conventional quasi-resonant ZVS inverter for induction-heated cooker, together with its power regulation characteristics on the basis of its simulation and experimental results. The steady-state performances of this inverter developed for multi-burner type induction-heated food cooking appliance are evaluated and discussed from a practical point of view.

  • PDF

An esthetic appliance for the management of crown-root fracture: a case report

  • Jeon, Sang-Min;Lee, Kang-Hee;Jung, Bock-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.226-229
    • /
    • 2014
  • Orthodontic extrusion is usually performed by means of a fixed orthodontic appliance that utilizes arch wire attached to adjacent teeth and transfers the desired force by elastic from the wire to the root. However, clinicians often encounter cases where the bonding required for tooth traction is not possible because the adjacent teeth have been restored with ceramic or veneer. The purpose of this case report is to describe a modified orthodontic extrusion appliance that is useful when conventional orthodontic treatment is not possible. The modified appliance was fabricated using an artificial tooth, clear plastic sheeting, and a braided fiber-reinforced composite strip that covered adjacent teeth without bonding. It satisfied the esthetic and functional needs of the patient and established the optimal biologic width.

Development of ultra high frequency Surgery machine using LCC Inverter (LCC인버터를 이용한 초고주파 수술기 개발)

  • Kim, Sang-Hyo;Lee, Joon-Tark;Lee, Oh-Keol
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2328-2330
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows. Therefore this treatise developed electricity living body formation operation appliance by home production. Ultra high frequency eruption circuit used LC circuit, and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current.

  • PDF

Development of electric surgical machine by LC series resonance (LC 직렬공진에 의한 전기 수술기 개발)

  • Lee, Oh-Keol;Kim, Tae-Woo;Song, Ho-Shin
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.153-157
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows, Therefore, this treatise developed electricity living body formation operation appliance by home production, Ultra high frequency eruption circuit used LC circuit, and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

Development of skin surgical machine by series resonance method (직렬공진에 의한 피부 수술기 개발)

  • Lee, Oh-Keol;Kim, Sang-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.127-132
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows. Therefore, this treatise developed electricity living body formation operation appliance by home production. Ultra high frequency eruption circuit used LC circuit. and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

The frog appliance for upper molar distalization: a case report (Frog appliance를 이용한 상악 대구치의 원심 이동: 증례 보고)

  • Bayram, Mehmet;Nor, Metin;Kilkis, Dogan
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.50-60
    • /
    • 2010
  • The purpose of this article was to evaluate the effects of a new upper molar distalization system, the Frog Appliance, on dentofacial structures in a Class II, division 1 patient. An 11-year-old girl was referred to our clinic for orthodontic treatment. She had a mild skeletal Class II malocclusion with Class II molar and canine relationship on both sides. The treatment plan included distalization of the upper first molars bilaterally followed by full fixed appliance therapy. For the upper molar distalization, a new system, the Frog Appliance, was constructed and applied. Lateral cephalometric radiographs were used to evaluate the treatment results. Distalization of the upper first molars was achieved in four months successfully, and Class I molar relationship was obtained. Total treatment time was 16 months. According to the results of the cephalometric evaluation, a nearly bodily distal molar movement with a slight anchorage loss was attained. In conclusion, the Frog Appliance was found to be a simple, ef ective, non-invasive, and compliance-free intraoral distalization appliance for achieving bilateral molar distalization.

Berlin standard activator in the treatment of growing patients with mandibular deficiency: Case report (성장기 하악골 열성장 환자의 Berlin standard activator를 이용한 부정교합 치료: 증례보고)

  • Lee, Seung-Youp
    • The Journal of the Korean dental association
    • /
    • v.48 no.11
    • /
    • pp.819-828
    • /
    • 2010
  • Activator is a removable functional appliance used for correcting the skeletal Class II malocclusion in children with the mandibular deficiency. Berlin standard activator modified from Andresen activator has following characters; do not cover the palatal surface for tongue space, relief on lingual surface of mandibular incisors and resin capping 1/3-1/2 of crown height on mandibular incisors for preventing labioversion of mandibular incisors, L-hook between maxillary lateral incisor and canine for anterior high pull headgear, relief on mandibular posterior bite block for differential eruption of posterior teeth. Two cases presented here had a mandibular deficiency and slight maxillary protrusion. First case (an 11-year-old girl) treated with Berlin standard activator and anterior high pull headgear for 13 months followed by fixed orthodontic appliance for another 29 months. Second case (a 12-year-old boy) treated with Berlin standard activator for 6 months followed by fixed appliance for another 24 months. Treatment results showed a significant improvement in sagittal skeletal and occlusal relationship without premolar extraction. Mandibular condyles were concentric in TMJ [ossa, and masticatory muscle activities were normalized after treatment. In the retention period facial harmony and occlusal stability was maintained.

Long-term effects of chlorhexidine varnish treatment on microbial changes of dental plaque in orthodontic patients with fixed appliances (Chlorhexidine varnish 처치 후 고정식 교정장치 장착 환자의 치태내 균주 변화 양상에 대한 장기간 관찰 연구)

  • Chang, Young-Il;Yang, Won-Sik;Nahm, Dong-Seok;Kim, Tae-Woo;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.335-342
    • /
    • 2000
  • The authors observed the long term effects of chlorhexidine varnish treatment on microbial change of dental plaque in orthodontic patients with fixed appliances. The initial sample was 100 patients who were arranged to be treated with fixed orthodontic appliances. The final sample consisted of 21 patients who could be traced for 32 weeks after application of fixed orthodontic appliances. They were classified into the experimental group (12 patients) and the control group (9 patients). The experimental group was treated with chlorhexidine varnish once a week for 4 weeks before application of fixed orthodontic appliance. The control group was not treated with chlorhexidine varnish before application of fixed orthodontic appliance. The experimental group was treated once more after 20 weeks. The microbial changes of dental plaque were analysed by indirect immunofluorescence technique at pre-treatment, post-treatment 4, 8, 20, and 32 weeks. The results were as follows. 1. In the experimental group, streptococus mutans was significantly suppressed during experimental period. (p<0.01) But, in the control group, streptococcus mutans was significantly increased after placement of fixed orthodontic appliances during experiment period. (p<0.05) 2. Streptococcus sanguis, Streptococcus mitis, Actinomyces viscosus, md Actinomyces naeslundii did not show significant change between the experimental and the control group during experiment period. So, if we treat the orthodontic patients with chlorhexidine varnish before application of fixed appliances, we may suppress the major cariogenic bacteria, Streptococcus mutans, selectively for long period.

  • PDF

Periodontal disease-related recognition and oral health-related behavior in orthodontic patients with fixed appliance (고정성 교정장치 장착환자의 치주질환관련 지식 및 구강건강관련 행태)

  • Choi, Kyung-Sun;Moon, Sang-Eun;Kim, Yun-Jeong;Kim, Seon-Yeong;Cho, Hye-Eun;Kang, Hyun-Joo
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.5
    • /
    • pp.747-755
    • /
    • 2017
  • Objectives: The purpose of study is to investigate periodontal disease-related recognition and oral health-related behavior in orthodontic patients with fixed appliance. Methods: A self-reported questionnaire was completed by 286 orthodontic patients with fixed appliance in Gwangju, Jeonnam from September 1 to September 27, 2016. The questionnaire consisted of general characteristics (3 items), orthodontic related characteristics (3 items), knowledge of periodontal disease (3 items), and oral health-related behavior (4 items). The data were analyzed by frequency analysis, percentage and chi-square analysis using SPSS 21.0 program. Results: 62.8% had experiences of dental treatment and 67.5% had intention of involvement on incremental care program in orthodontic treatment periods. Accuracy rate of cause about periodontal disease was high in female and case of acquiring information experiences on periodontal disease (p<0.05). 67.2% performed correct toothbrushing for the management of periodontal disease in the experiences of acquiring information on periodontal disease in orthodontic treatment periods (p<0.05). The proportions of using interdental toothbrush and mouth rinsing solutions were high among those over 20 years old and students in the subjects (p<0.05). Conclusions:The accuracy rate were high in the answers about cause and management of periodontal disease in case of acquiring information experiences on periodontal disease in orthodontic treatment periods. Therefore, there is a need to further development and implementation of dental hygiene intervention program for periodontal disease care with fixed orthodontic appliances in that regard.

Maxillary molar derotation and distalization by using a nickel-titanium wire fabricated on a setup model

  • Jung, Jong Moon;Wi, Young Joo;Koo, Hyun Mo;Kim, Min Ji;Chun, Youn Sic
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.268-274
    • /
    • 2017
  • The purpose of this article is to introduce a simple appliance that uses a setup model and a nickel-titanium (Ni-Ti) wire for correcting the mesial rotation and drift of the permanent maxillary first molar. The technique involves bonding a Ni-Ti wire to the proper position of the target tooth on a setup model, followed by the fabrication of the transfer cap for indirect bonding and its transfer to the patient's teeth. This appliance causes less discomfort and provides better oral hygiene for the patients than do conventional appliances such as the bracket, pendulum, and distal jet. The treatment time is also shorter with the new appliance than with full-fixed appliances. Moreover, the applicability of the new appliance can be expanded to many cases by using screws or splinting with adjacent teeth to improve anchorage.