• Title/Summary/Keyword: Fixed Joint

Search Result 329, Processing Time 0.025 seconds

A Study on Object Tracking for Autonomous Mobile Robot using Vision Information (비젼 정보를 이용한 이동 자율로봇의 물체 추적에 관한 연구)

  • Kang, Jin-Gu;Lee, Jang-Myung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.2
    • /
    • pp.235-242
    • /
    • 2008
  • An Autonomous mobile robot is a very useful system to achieve various tasks in dangerous environment, because it has the higher performance than a fixed base manipulator in terms of its operational workspace size as well as efficiency. A method for estimating the position of an object in the Cartesian coordinate system based upon the geometrical relationship between the image captured by 2-DOF active camera mounted on mobile robot and the real object, is proposed. With this position estimation, a method of determining an optimal path for the autonomous mobile robot from the current position to the position of object estimated by the image information using homogeneous matrices. Finally, the corresponding joint parameters to make the desired displacement are calculated to capture the object through the control of a mobile robot. The effectiveness of proposed method is demonstrated by the simulation and real experiments using the autonomous mobile robot.

  • PDF

Process and Strength Evaluation of Mechanical Press Joining (기계적 프레스 접합의 공정 및 강도 평가)

  • Lee, Sang-Hoon;Kim, Ho-Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.1-6
    • /
    • 2011
  • New methods for joining sheet of metal are being sought. One of the most promising methods is MPJ (mechanical press joining). It has been used in thin metal work because of its simple process and relative advantages over other methods, as it requires no fasteners such as bolts or rivets, consumes less energy than welding, and produces less ecological problems than adhesive methods. In this study, the joining process and static behavior of single overlap joints has been investigated. During fixed die type joining process for SPCC plates, the optimal applied punching force was found. The maximum tensile-shear strength of the specimen produced at the optimal punching force was 1.75 kN. The FEM analysis result on the tensile-shear specimen showed the maximum von-Mises stress of 373 MPa under the applied load of 1.7 kN, which is very close to the maximum tensile strength of the SPCC sheet(= 382 MPa). This suggests that the FEM analysis is capable of predicting the maximum tensile load of the joint.

Before and After Cruciate Ligament Reconstruction Comparison of Isokinetic Muscle Strength for Knee Extensor Muscles (십자인대재건술 전과 후의 무릎신전근육에 대한 등속성 근력 비교)

  • Moon, Dal-joo;Kim, Jong-woo;Hwang, Byeong-jun
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.2
    • /
    • pp.37-43
    • /
    • 2021
  • Background: The purpose of this study is to compare and analysis the changes in strength and endurance of the knee extensor muscles after Anterior cruciate ligament reconstruction. Methods: Twelve male subjects with ligament injury were seated on Biodex and the hip joint was flexed at 110°, and torso, lower extremities, and legs were fixed using Velcro. The resistance device was placed at a point 3cm above the ankle, and measurements were taken before and a surgery at 60°/sec and 180°/sec when the knee was maximally extended. The postures ingeniously combine forward-bending poses countered with backward-bending ones. Results: There was no significant difference in the comparison of muscle strength of 60°/sec and 180°/sec before surgery. But there was a significant difference after surgery. There was significant difference in muscle endurance both before and after surgery. There was a significant difference in the pre- and post- operative comparison values of muscle strength and endurance in isokinetic movements at 60°/sec and 180°/sec during knee extension on the injured side. Conclusion: For cruciate ligament tears, Orthopedic reconstruction is recommended. Correct alignment of the knee ligament after surgery can enhance the strength and endurance of the quadriceps femoris during knee extension rejuvenated.

Robust Secure Transmit Design with Artificial Noise in the Presence of Multiple Eavesdroppers

  • Liu, Xiaochen;Gao, Yuanyuan;Sha, Nan;Zang, Guozhen;Wang, Shijie
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.6
    • /
    • pp.2204-2224
    • /
    • 2021
  • This paper studies secure wireless transmission from a multi-antenna transmitter to a single-antenna intended receiver overheard by multiple eavesdroppers with considering the imperfect channel state information (CSI) of wiretap channel. To enhance security of communication link, the artificial noise (AN) is generated at transmitter. We first design the robust joint optimal beamforming of secret signal and AN to minimize transmit power with constraints of security quality of service (QoS), i.e., minimum allowable signal-to-interference-and-noise ratio (SINR) at receiver and maximum tolerable SINR at eavesdroppers. The formulated design problem is shown to be nonconvex and we transfer it into linear matrix inequalities (LMIs). The semidefinite relaxation (SDR) technique is used and the approximated method is proved to solve the original problem exactly. To verify the robustness and tightness of proposed beamforming, we also provide a method to calculate the worst-case SINR at eavesdroppers for a designed transmit scheme using semidefinite programming (SDP). Additionally, the secrecy rate maximization is explored for fixed total transmit power. To tackle the nonconvexity of original formulation, we develop an iterative approach employing sequential parametric convex approximation (SPCA). The simulation results illustrate that the proposed robust transmit schemes can effectively improve the transmit performance.

The Impact of Minimum Wage Policy on Employment in Myanmar

  • KYAW, Min Thu;CHO, Yooncheong
    • The Journal of Industrial Distribution & Business
    • /
    • v.12 no.3
    • /
    • pp.31-41
    • /
    • 2021
  • Purpose: The purpose of this paper is to analyze the impact of the minimum wage policy and the employment labor force in Myanmar by exploring firms' actions such as installing supplementary machines to substitute for labor resources and by addressing gender issues in employment. Research design, data, and methodology: This paper applies a fixed-effect estimation method by using the World Bank's enterprise panel data set surveyed in Myanmar. Results: Findings suggest that the minimum wage reduces both full-time and part-time employment, while the first minimum wage policy increases overall female employment. The adverse impacts are more pronounced for female employees of Joint Venture enterprises and enterprises located in the less-populated regions. Investment in capital such as equipment and machinery increase to substitute for labor after the minimum wage policy implementation; as a result, full-time employment slightly decreases. Conclusions: Appropriate measures concerning the minimum wage policy must be prepared by the government and institutions related to the labor union to serve the well-being of employees. Government of Myanmar should fix the minimum wage in a reasonable period based on the fiscal year for both employers and employees to prevent possible issues and losses resulting from the minimum wage being set.

Complex open elbow fracture-dislocation with severe proximal ulna bone loss: a case report of massive osteochondral allograft surgical treatment

  • Concina, Chiara;Crucil, Marina;Theodorakis, Emmanouil;Saggin, Giorgio;Perin, Silvia;Gherlinzoni, Franco
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • We report a case of a 69-year-old right-dominant man who had an open Monteggia-like lesion of the right elbow (Gustilo-Andersen IIIA) with severe proximal ulna bone loss associated with an ipsilateral ulnar shaft fracture due to a motorcycle accident. The patient underwent two-stage surgery. Wound debridement and bridging external fixation were performed at first. Three months later, a frozen massive osteochondral ulnar allograft was implanted and fixed with a locking compression plate. A superficial wound infection appeared 5 weeks after the second surgery. Superficial wound debridement, negative pressure therapy, and antibiotics were administered for 3 months, achieving infection healing. At 3 years post-surgery, the elbow range of motion was satisfactory with a Disabilities of the Arm, Shoulder and Hand (DASH) score of 16.7. Radiographs and computed tomography scans showed good allograft-bone integration without allograft reabsorption or hardware loosening. Although not complication-free, massive ulna osteochondral allograft implantation can be considered a valid option in cases of open Monteggia-like lesions associated with ulnar shaft fracture and severe bone loss in active patients, whenever osteosynthesis or joint replacement is not a proper solution. This type of bone stock restoration allows for future surgery, if needed.

Dual Mobility Cup for Revision of Dislocation of a Hip Prosthesis in a Dog with Chronic Hip Dislocation

  • Jaemin Jeong;Haebeom Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.390-394
    • /
    • 2022
  • A 6-year-old, 36.5 kg castrated male Golden Retriever presented for revision surgery for left total hip replacement. The patient underwent removal of the cup and head implants due to unmanageable prosthetic hip dislocation, despite revision surgery. On physical examination, the dog showed persistent weight-bearing lameness after exercise of the left hindlimb with mild muscle atrophy. Radiographic examination revealed dorsolateral displacement of the femur with a remnant stem and bony proliferation around the cranial and caudal acetabulum rims. The surgical plan was to apply the dual mobility cup to increase the range of motion and jump distance to correct soft tissue elongation and laxity caused by a prolonged period of craniodorsal dislocation of the femur. The preparation of the acetabulum for cup fixation was performed with a 29-mm reamer, and the 29.5-mm outer shell was fixed with five 2.4-mm cortical screws. The head and medium neck of the dual-mobility system were placed on the cup, and the hip joint was reduced between the neck and stem. The dog exhibited slight weight bearing on a controlled leash walk the day after surgery. The patient was discharged 2 weeks postoperatively without any complications. Six months postoperatively, osseointegration and a well-positioned cup implant were observed, and the dog showed excellent limb function without hip dislocation until 18 months of phone call follow-up.

Dynamic responses of a freestanding bridge tower under wave and wave-current loads

  • Wei, Chengxun;Wang, Wenjing;Zhou, Daocheng
    • Structural Engineering and Mechanics
    • /
    • v.82 no.4
    • /
    • pp.491-502
    • /
    • 2022
  • A model experiment with a scale of 1:150 has been conducted to investigate the dynamic responses of a freestanding four-column bridge tower subjected to regular wave, random wave and coupled wave-current actions. The base shear forces of the caisson foundation and the dynamic behaviors of the superstructure were measured and analyzed. The comparisons of the test values with the theoretical values shows that wave-induced base shear forces on the bridge caisson foundation can be approximated by using a wave force calculation method in which the structure is assumed to be fixed and rigid. Although the mean square errors of the base shear forces excited by joint random wave and current actions are approximately equal to those excited by pure random waves, the existence of a forward current increases the forward base shear forces and decreases the backward base shear forces. The tower top displacements excited by wave-currents are similar to those excited by waves, suggesting that a current does not significantly affect the dynamic responses of the superstructure of the bridge tower. The experiment results can be used as a reference for similar engineering design.

An Immune-Electron Microscopic Study for Cluster Designation on the Phagocytic Synovial Cells in the Knee Joint of the Human (인체 무릎관절 윤활포식세포 cluster designation 표지에 관한 면역전자현미경적 연구)

  • Lim, Hyoung-Soo;Cho, Kook-Hyeung;Kim, Yong-Wook;Park, Kyeong-Han;Hwang, Young-Il;Chang, Ka-Young;Hwang, Douk-Ho
    • Applied Microscopy
    • /
    • v.30 no.2
    • /
    • pp.173-183
    • /
    • 2000
  • This study was designed to observe the ultrastructural localization of synoviocytes, which are concerned with the function of phagocytic synovial cells (type A synoviocytes, macrophage-like synoviocytes), in the knee joint of the human for CD14 and CD105 by cryo-immune-electron microscopic technique. The synovium were dissected and fixed for two hours (in 4% paraformaldehyde and 0.1% glutaraldehyde mixture), and were immerged in 2.3 M sucrose and 20% PVP solution. Finally, they were cut with the cryoultramicrotome and labelled with primary antibodies (monoclonal mouse anti-human CD14, monoclonal mouse anti-human CD105 (endoglin) and secondary (donkey anti-mouse IgG) tagged with 6 nm colloidal gold particles. The tissues were observed under transmission electron microscope. This study was resulted as follows. 1. In the synovium of the human knee joint, CD14+ cells were identified. These cells showed phagocytic synovial cell's features. In the phagocytic synoviocyte, the distributions of CD14 were marked in the cytoplasm, around vacuoles, and in cytoplasmic process, but not detected inside of vacuoles. 2. In the synovium of the human knee joint, CD105+ cells were identified. These cells were recognized endothelial cells and phagocytic synovial cells. In the phagocytic synovial cells, the distributions of CD105 (endoglin) were marked in cytoplasic process, around vacuoles, and in cell membrane, but not detected inside of vacuoles. On the basis of above findings, it is obvious that phagocytic synovial cells were marked at CD 14 and CD 105, and might be play the role of activated macrophages or phagocytes in the synovial membrane.

  • PDF

A FINITE ELEMENT ANALYSIS ON THE 3-UNIT FIXED PROSTHESIS SUPPORTED WITH A NATURAL TOOTH AND ANGLE VARIABLE IMPLANT (고정성 보철치료에서 골유착성 임프란트의 경사도변화에 따른 변위와 응력에 관한 유한요소적 연구)

  • Ko Hyun;Woo Yi-Hyung;Park Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.580-610
    • /
    • 1993
  • The purpose of this study was to analyse the deflection and stress distribution at the supporting bone and it's superstructure by the alteration of angulation between implant and it's implant abutment. For this study, the free-end saddle case of mandibular first and second molar missing would be planned to restore with fixed prosthesis. So the mandibular second premolar was prepared for abutment, and the cylinder type osseointegrated implant was placed at the site of mandibular second molar for abutment. The finite element stress analysis was applied for this study. 13 two-dimensional FEM models were created, a standard model at $0^{\circ}$ and 12 models created by changing the angulation between implant and implant abutment as increasing the angulation mesially and distally with $5^{\circ}$ unittill $30^{\circ}$. The preprocessing decording, solving and postprocessing procedures were done by using FEM analysis software PATRAN and SUN-SPARC2GX. The deflections and von Mises stresses were calculated under concentrated load (load 1) and distributed load(load 2) at the reference points. The results were as follows : 1. Observing at standard model, the amount of total deflection at the distobuccal cusp-tip of pontic under concentrated load was largest of all, and that at the apex of implant was least of all, and the amount of total deflection at the buccal cusp-tip of second premolar under distributed load was largest of all, and that at the apex of implant was least of all. 2. Increasing the angulation mesially or distally, the amounts of total deflection were increased or decreased according to the reference points. But the order according to the amount of total deflection was not changed except apex of second premolar and central fossa of implant abutment under concentrated load during distal inclination. 3. Observing at standard model, the von Mises stress at the distal joint of pontic under concentrated load was largest of all, and that at the apex of implant was least of all. The von Mises stress at the distal margin of second premolar under distributed load was largest of all, and that at the apex of Implant was least of ail. 4. Increasing the angulation of implant mesially, the von Mises stresses at the mesial crest of implant were increased under concentrated load and distributed load, but those were increased remarkably under distributed load and so that at $30^{\circ}$ mesial inclination was largest of all. 5. Increasing the angulation of implant distally, the von Mises stresses at the distal crest of implant were increased remarkably under concentrated load and distributed load, and so those at $30^{\circ}$ distal inclination were largest of all.

  • PDF