• Title/Summary/Keyword: Fixed Carrier Concentration($SO_3^{2-}$)

Search Result 2, Processing Time 0.015 seconds

Effect on Physiological Metabolism of Calcium Ion at Cell Membrane Model of Parathyroid which Irradiated by High Energy X-ray (고에너지 엑스선을 조사한 부갑상선의 세포막모델에서 칼슘이온의 생리학적 대사에 미치는 영향)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.141-150
    • /
    • 2022
  • The initial co-transport and counter-transport permeate transport characteristics of calcium ion at epithelial cell membrane model in parathyroid which irradiated by high energy x-ray(linac 6 MV) was investigated. The epithelial cell membrane model used in this experiment was a polysulfonated copolymerized membrane of poly(PS-DVB: polystyrene-divinylbenzene). The difference of sorbed water in membrane, fixed carrier concentration(SO32-), initial pH value, OH- concentration were occurred at difference of Ca2+concentration and quantity of parathyroid hormone, respectively. The initial co-transport and counter-transport permeate flux of Cl-, OH-, Ca2+ on fixed carrier concentration(SO32-) and initial pH value of irradiated membrane was found to be decreased than non-irradiated membrane. The initial co-transport and counter-transport permeate flux of Ca2+ on fixed carrier concentration (SO32-), initial pH value, OH- concentration in irradiated membrane were found to be decreased about 2.68 ~ 6.87 times, about 1.42 ~ 1.63 times, about 2.07 ~ 1.672 times than non-irradiated membrane, respectively. As a result, the quantity of parathyroid hormone was decreased at irradiated membrane than non-irradiated membrane. The decrease of parathyroid hormone was occurred at hypoparathyroidism and osteoporosis, parathyroiditis, and so on. As the parathyroid hormone in epithelial cell membrane model were abnormal, cell damages were appeared at cell.

Organopalladium(II) Complexes as Ionophores for Thiocyanate Ion-Selective Electrodes

  • Kim, Dong-Wan;Lee, So-Hyun;Kim, Jung-Hwan;Kim, Jin-Eun;Park, Jong-Keun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2303-2308
    • /
    • 2009
  • A thiocyanate poly(vinyl chloride) (PVC) membrane electrode based on [1,2-bis(diphenylphosphino)ethane]dihalopalladium( II), [(dppe)$PdX_2$, X = Cl ($L^1$), X = I ($L^2$)] as active sensor has been developed. The diiodopalladium complex, [(dppe)$PdI_2](L^2$) displays an anti-Hofmeister selectivity sequence: $SCN^-\;>\;I^-\;>\;{ClO_4}^-\;>\;Sal^-\;>\;Br^-\;>\;{NO_2}^-\;>\;{HPO_4}^-\;>\;AcO^-\;>\;{NO_3}^-\;>\;{H_2PO_4}^-\;>\;{CO_3}^{2-}$. The electrode exhibits a Nernstian response (-59.8 mV/decade) over a wide linear concentration range of thiocyanate ($(1.0\;{\times}\;10^{-1}\;to\;5.0\;{\times}\;10^{-6}$ M), low detection limit ($(1.1\;{\times}\;10^{-6}$ M), fast response $(t_{90%}$ = 24 s), and applicability over a wide pH range (3.5∼11). Addition of anionic sites, potassium tetrakis[p-chlorophenyl] borate (KTpClPB) is shown to improve potentiometric anion selectivity, suggesting that the palladium complex may operate as a partially charged carrier-type ionophore within the polymer membrane phase. The reaction mechanism is discussed with respect to UV-Vis and IR spectroscopy. Application of the electrode to the potentiometric titration of thiocyanate ion with silver nitrate is reported.