• 제목/요약/키워드: Fixed Bed

Search Result 516, Processing Time 0.023 seconds

A Study on the Optimal Design in the Indirect Aerated Fluidized Bed (간접 포기식 유동상의 이상적 설계에 관한 연구)

  • 안송엽;김환홍;권희태
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.95-100
    • /
    • 1999
  • Process intensification without any increase in bed requires the exploitation of fluid mechanical phenomena as the basis for elegant solutions to the process engineering problems which result from the need to retain and control the immobilized biomass, and for biomass recovery. The fluidized bed biological reactor provides a solution to these needs. The wastewater treatment characteristics of the fluidized bed was filled with sand media. Indirect aeration were studied experimentally. The researcher was filled with sand particle size(0.60~0.42mm) in three reactors with different section area(A)/height(H), in the state BOD loading 4.5kg-$BOD_5/m^3$ㆍd, and under the fixed state of hydraulic retention time for around 32 minutes.

  • PDF

A Study on Combustion & Flue Gas Characteristics of Coal at Pressurized Fluidized Bed Combustor (가압유동층연소로에서 석탄의 연소 및 배가스특성 연구)

  • Han, Keun-Hee;Oh, Dong-Jin;Ryu, Jung-In;Jin, Gyoung-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.677-686
    • /
    • 2000
  • The characteristics of combustion and of emissions in pressurized fluidized bed combustor are investigated. The pressure of the combustor is fixed at 6 atm, and the combustion temperatures are set to 850, 900, and $950^{\circ}C$. The gas velocities are 0.9, 1.1, and 1.3 m/s. The excess air ratio is varied from 5 to 35%. The coal used in the experiment is Shenhwa coal in China. All experiments are executed at 2m bed height. Consequently, NOx & $N_2O$ concentration in the flue gas is increased with incresing excess air ratio but $SO_2$ concentration is decreased with incresing excess air ratio. CO concentration is maintained below 100ppm at over 15% of excess air ratio.

Catalytic Pyrolysis of Various Carbon Number Feed Oil Using a Spouted Bed Reactor (Spouted Bed Reactor를 이용한 다양한 탄소수 원료유 촉매 열분해)

  • Yoo, Kyeong Seun;Park, Sung Hoon;Park, Young-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.627-630
    • /
    • 2011
  • We focus on a catalytic process based on direct injection method that can produce high-quality oils of gasoline and kerosene with various carbon-number feed oils. The reaction characteristics of a commercial catalyst were analyzed using a spouted bed reactor. Decane and pentadecane were used to compare the characteristics of the fixed bed and the spouted bed reactor. The yield of gasoline plus kerosene was highest at the reaction temperature of $550^{\circ}C$. For the spouted bed reactor, the at-a-pulse injection was more effective for catalytic cracking of feed oils than multiple consecutive injections. The reaction activity became higher as the carbon number of feed oil is larger.

Design of the Busan-Geoje Fixed Links Immersed tunnel (기획특집 - 거가대교 침매터널의 설계)

  • Lee, Jung-Sang
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.2
    • /
    • pp.30-33
    • /
    • 2010
  • Immersed tunnel had been a rather new term in Korea before Busan-Geoje fixed link project was started and became known through the media. Although Korean is unfamiliar with the immersed tunnel, this construction method has a long history in the world. Busan-Geoje Fixed Link immersed tunnel consist of 18 elements and each element is approximately 180m long. These tunnel elements are prefabricated of reinforced concrete in a temporary dry dock and are towed to the site and lowered into final position in a dredged trench and are placed on a screeded gravel bed directly without temporary support.

  • PDF

Allowable Amount of Bed Inventory in a 300 MW Class Circulating Fluidized Bed Boiler (300 MW 급 유동층보일러에서 적정 층 물질량 산정)

  • Kim, Woo-Yong;Yoo, Ho-seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2018
  • The CFB boilers technology is facing a number of challenges. Among them, boiler tube erosion, sintering by bed inventory overheating and high self consumed service power are major ones. This study was conducted to obtain allowable bed inventory with the Yeosu Power Plant, a 300 MW class CFB boiler. For the test, bed pressure was reduced from design pressure of 4.5 KPa to 2.5 KPa by reducing bed inventory, at fixed turbine output, coal consumption rate and air flow. Consequently, reducing the lower bed inventory is effective to decrease bed temperature but excessive reducing might increase bed temperature due to lack of circulating fluidized materials. Also, in case of the Yeosu Plant boiler using subbituminous coal as its primary fuel, its bed temperature change is highly affected by not only the amount of bed inventory, but also the boiler capacity and coal contents.

  • PDF

Removal Characteristics of Lithium Ions by Fixed-bed Column Packed with Strong-Acid Cation Exchange Resin (강산성 양이온 교환수지를 충전한 고정층에서 리튬이온의 제거특성)

  • You, Hae-Na;Lee, Min-Gyu
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.166-170
    • /
    • 2014
  • The continuous experiments were carried out using fixed-bed column packed with strong-acid cation exchange resin for the removal of lithium ions from aqueous solution. The parameters such as bed height, flow rate and inlet concentration were investigated. Breakthrough time ($t_{0.05}$), saturation time ($t_{0.95}$), and total amount of lithium ion removed (mtotal) were obtained from the breakthrough curves. The results showed that $t_{0.05}$ and $t_{0.95}$ decreased with decreasing bed height, and decreased with increasing inlet concentration and flow rate. mtotal increased with increasing inlet concentration and bed height, but decreased with increasing flow rate. Thomas model and Yoon-Nelson model equations were applied to the experimental data, the results showed that the breakthrough data gave a good fit to Thomas model equation.

Characteristics of Lead Removal in a Fixed-Bed Column Packed with Crab Shell Particles (게껍질 충진 칼럼에 의한 납의 제거 특성)

  • Lee, Moo-Yeal;Kang, Hyun-Ah;Yang, Ji-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1747-1756
    • /
    • 2000
  • Crab shell particles (Protunus trituberculatus) and activated carbon (Norit 0.8 SUPRA) were used as packing material in a fixed-bed column. When 1 g crab shell was added in the column packed with 10 g activated carbon. breakthrough to influent 10 mg Pb/L occurred at 1520 bed volumes. as compared to 380 bed volumes for 10 g activated carbon only. Addition of crab shell particles into activated carbon column resulted in increased uptake of lead. The dramatic improvement might be attributed to an increase in $co_3{^{2-}}$ and $OH^-$ available for the binding of lead. From the result of analyses, the major mechanism of lead removal was based on dissolution of $CaCO_3$ in the crab shell followed by precipitation of $Pb_3(CO_3)_2(OH)_{2(s)}$ on the surface of activated carbon. The lead uptake increased two fold as the influent lead concentration was increased from 10 to 50 mg/L. However, it decreased by 40% as the influent pH was lowered from 5.0 to 3.0.

  • PDF

The effect on the components variation of syngas by changing temperature and steam addition in biomass gasification process (바이오매스 가스화 과정에서의 온도와 가습의 변화가 전환가스 조성에 미치는 영향)

  • Ahn, Seong-Yool;Choi, Gyung-Min;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3429-3434
    • /
    • 2007
  • An experimental study was carried out to investigate gasification process of wood sawdust in the I-dimensional downdraft fixed bed gasifier. The preheated air was used oxidizer and steam were used as a gasifying agent. The operating parameters, the supplied air temperature and steam were used. The oxidizer temperature was varied from 500K to 620K and vapor was added. The gasification process was monitored by measuring temperature at three position near the biomass using R-type thermocouples and the syngas composition was analyzed by gas chromatograph. The change of hydrogen and carbon monoxide, carbon dioxide, methane was observed. Overall, the volume fraction of hydrogen and methane were increased widely as increasing the oxidizer temperature and adding steam.

  • PDF

Biological Treatemnt of Dye Wastewater Using an Anaerobic-Aerobic System (혐기-호기 공정을 이용한 염료페수의 생물학적 처리)

  • 박영식;문정현;안갑환
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.569-576
    • /
    • 2002
  • Anaerobic/aerobic reactor system was used to treat a synthetic wastewater with glucose as carbon sources(0.38~2.29 kg COD/m3.day) and Acid Red 14(1.05 "24.00 g Acid Red 141m3.day, color degree of 570 ~ 1710). COD removal efficiency by the anaerobic stage in operation period were above 90 % organic loading rate of 0.38 ~ 2.29 kg COD/m3.day(except, adaptation period) and the removal efficiency of the whole system were above 96 %. The decolorization of the Acid Red 14 was through the alteration of the dye structure(or cleavage of the Azo bond) during the anaerobic treatment. In the A/A system, the anaerobic stage played an essential role in removing both color and COD. In addition it also improves biodegradability of dye f3r further aerobic treatment. After operation, average MLSS concentration of anaerobic sludge reactor, anaerobic fixed-bed reactor and aerobic fixed-bed reactor were 17100mg/L, 20000mg/L, and 10000mg/L, respectively.

The effect oxidizer temperature and steam addition on caloric value in biomass gasification process (공급공기의 온도 변화와 수증기가 바이오매스 가스화 과정에서 전환가스의 발열량에 미치는 영향)

  • Ahn, Seong-Yool;Mun, Cheol-Eon;Choi, Gyung-Min;Kim, Duck-Jool
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.606-609
    • /
    • 2007
  • An experimental study was carried out to investigate the heat value change by various conditions of wood sawdust gasification in the 1-dimensional downdraft flow fixed bed gasifier. The preheated air and steam were used as a gasifying agent. The components of syngas were influenced increasing residence time of supplied agent. The operating parameters, the supplied agent temperature and steam addition were used. The oxidizer temperature was varied from 500K to 620K. The gasification process was monitored by measuring temperature at three points near the biomass using R-type thermocouples and the syngas composition was analyzed by gas chromatograph. We get the sample gas at the end of gasifier. Finally, the amount of hydrogen and methane were increased widely as increasing the oxidizer temperature and adding steam.

  • PDF