• Title/Summary/Keyword: Fixation Duration

Search Result 125, Processing Time 0.023 seconds

Cortical lag screw fixation for the management of mandibular injuries

  • Elsayed, Shadia Abdel-Hameed
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.6
    • /
    • pp.393-402
    • /
    • 2020
  • Objectives: Here, we present cases of mandibular fracture that were managed with the cortical lag screw fixation technique (CLSFT) in order to critically evaluate technique indications and limitations of application at various fracture sites. Materials and Methods: This was a retrospective cohort study. The study sample was composed of patients suffering from mandibular fractures that were treated by the CLSFT. The outcome variables were fracture type, duration of surgery, number of screws, and pattern of application. Other study categories included patient demographics and causes of injury. Chi-square tests were used to assess descriptive and inferential statistical differences, and the P-value was set at 0.05. Results: Thirty-three patients were included in the study sample, with a mean age of 30.9±11.5 years and a male predominance of 81.8%. The technique was applied more frequently in the anterior mandibular region (51.5%) than in other sites. Double CLSFT screws were required at the symphysis and parasymphysis, while single screws were used for body and angle regions. No intraoperative and postoperative variables were significantly different except for surgical duration, which was significantly different between the sites studied (P=0.035). Conclusion: We found that CLSFT is a rapid, cost-effective technique for the fixation of mandibular fractures yielding good treatment results and very limited complications. However, this technique is sensitive and requires surgical expertise to be applied to mandibular fractures that have specialized characteristics.

Methodology Development of Clothing Appearance by Eye Movement Analysis (안구운동 분석을 통한 의복의 시각적 평가의 객관화)

  • Park Hye-Jun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.6 s.154
    • /
    • pp.992-1000
    • /
    • 2006
  • The main purpose of this research is to develop the methodology of objective evaluation of clothing appearance by eye movement analysis. The visual clothing items used in this study were skirt, one-piece, pants and shirt with the style variation of silhouette and details. By observing eye movement during visual evaluation of clothing, we can achieve the basic fixation data of eye movement. Moreover, we developed the Matlab program to extract the fixation coordinate and number of eye fixation on each part of the clothing item. As results, there were differences in the duration of fixation time for each item and the fixation time was not different by styles within a clothing item. However, we could find differences in the fixation time within a style, in other words, we could select the important parts of the clothing by observing the fixation time in a certain clothing item. It is also noted that time required in visual information processing differs depending on the item, and there was a region which contain more information independent with styles in the same item. By developing the objective method of visual evaluation that correspond to human's visual information processing, the results are expected to be applied in the retrieval program in internet shopping mall or in the development of contents for advertisement of clothing.

Anterior Lumbar Interbody Fusion with Pedicle Screw Fixation for Elderly Isthmic Spondylolisthesis

  • Lee, Dong-Yeob;Lee, Sang-Ho;Maeng, Dae-Hyeon;Jang, Jee-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.3
    • /
    • pp.175-179
    • /
    • 2006
  • Objective : The surgical outcome of anterior lumbar interbody fusion[ALlF] with pedicle screw fixation for elderly isthmic spondylolisthesis was analyzed. Methods : Consecutive nineteen elderly patients [aged 65 years or more] with isthmic spondylolisthesis [Grade I or II] who underwent single level ALIF with pedicle screw fixation in 2002 were analyzed. Using clinical chart and mailed questionnaires, preoperative and postoperative Visual Analogue Scale[VAS] of back and leg pain and postopertive Macnab criteria were evaluated. Results : The mean age at the time of operation was 68.4 years [range 65 to 78 years]. Twelve patients underwent ALIF with percutaneous pedicle screw fixation. Seven patients underwent ALIF followed by posterior decompression and pedicle screw fixation. The postoperative complication rate was 10.5% [wound dehiscence in 1 patient and incisional hernia in 1 patient]. There was no postoperative major morbidity or mortality. At a mean follow-up duration of 30.7 months [range 25 to 35 months], 93.3% [14/15] of the patients showed excellent or good outcomes in terms of Macnab criteria. The mean VAS scores of back pain and leg pain significantly decreased after surgery. Conclusion : ALIF with pedicle screw fixation yielded favorable results for elderly isthmic spondylolisthesis in selected cases.

Investigation of Eye Movement on the Observation of Elementary School Students with Different Motivation System on Science Learning (관찰 상황에서 초등학생들의 과학학습 동기체계에 따른 시선이동 분석)

  • Lim, Sungman;Park, Seojung;Yang, Ilho
    • Journal of The Korean Association For Science Education
    • /
    • v.33 no.6
    • /
    • pp.1154-1169
    • /
    • 2013
  • The present work was performed to find behavioral characteristics of elementary school students corresponding to the motivation system on science learning (SL-BIS/BAS; Behavioral Inhibition/Activation System about Science Learning) in the observation situation. Eye-tracking was used for this study, which is one of the neurophysiological methods. The findings of present study were as follows: First, students who have sensitive motivation system to SL-BIS (SL-BIS group) showed meaningfully shorter fixation duration the whole time during an observation task than students who have sensitive motivation system to SL-BAS (SL-BAS group) (p<.05). Total fixation counts of SL-BIS group were significantly larger than SL-BAS group and it indicates that SL-BIS group often generated new fixations. Therefore, fixation duration per count of SL-BAS group was longer than that of SLBIS group. Second, we studied fixations in situations with movement corresponding to the motivation system on science learning. SL-BIS group and SL-BAS group exhibited similar fixation duration in the study task segment with movement, which is one of the stimulus attracting students. However, for the study task segment when the movement was finished, total fixation duration and fixation duration per count of SL-BAS group were meaningfully longer than those of SL-BIS group. Third, comparing fixation targets classified by factors of study task, SL-BIS group showed fixation on the target that is not important for the study task. But SL-BAS group concentrated on the target-related factor of the study task. The present work could be helpful in understanding students' characteristics corresponding to the motivation system on science learning in observation situation and for making a learning & teaching plan that is suitable to the feature of students.

User's Gaze Analysis for Improving Map Label Readability in Way-finding Situation

  • Moon, Seonggook;Hwang, Chul Sue
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.5
    • /
    • pp.343-350
    • /
    • 2019
  • Map labels are the most recognizable map elements using the human visual system because they are essentially a natural language. In this study, an experiment was conducted using an eye-tracker to objectively record and analyze the response of subjects regarding visual attention to map labels. A primary building object was identified by analyzing visit counts, average visit duration, fixation counts, and the average fixation duration of a subject's gaze for an area of interest acquired using the eye-tracker. The unmarked rate of map labels in Google map, Naver map, and Daum map was calculated. As a result, this rate exceeded fifty-one percent, with the lowest rate recorded for Google map. It is expected that the results of this study will contribute to an increase in the diversity of research in terms of the spatial cognition approach for map labels, which is more helpful to users than the existing body of work on methods of expression for labels.

Treatment for Tarsometatarsal Fracture-Dislocation (족근-중족 관절 골절 탈구의 치료경험)

  • Chung, Yung-Khee;Yoo, Jung-Han;Park, Yong-Wook;Noh, Dong-Geun;Ha, Sung-Han
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.2
    • /
    • pp.112-118
    • /
    • 1997
  • Tarsometatarsal fracture-dislocation is uncommon but severe lesion. Since this lesion is sometimes difficult to recognize by roentgenography, it is easily overlooked. Three patients were treated with open reduction and internal fixation with 3.5 mm cannulated screw and K-wire, two had treatment with open reduction and internal fixation with 3.5 mm cannulated screw only and two had treatment with dosed reduction and short leg cast only between January 1994 and May 1996. The duration of follow-up ranged from twelve to twenty-nine months after the diagnosis. Results were assessed by a subjective questiormaire, physical examination, and radiographic analysis. Multiple fixation techniques for maintaining the reduction of tarsometatarsl joint have been introduced. We recent]y used the 3.5 mm cannulated screw for internal fixation of the tarso-first and second metatarsal fracture-dislocation. We think cannulated screw fixation has several advantages; 1. The cannulated screw fixation is more rigid than the K-wire fixation. 2. There is an decreased risk of screw breakage with early weight bearing. 3. It is possible to compress the involved joints, if necessary. There were no disability in all patients. One patient who was treated with delayed open reduction and internal fixation with 3.5 mm cannulated screw and K-wire had a radiographic mild degenerative arthritis. And one patient who was treated with dosed reduction and short leg cast had a mild metatarsus adductus. But. these two patients were symptom free. There was no correlation between the severity of the diastasis and the patient s functional result.

  • PDF

Clinical and Structural Outcomes of Arthroscopic Intraarticular Knotless Fixation for Upper Subscapularis Tendon Tears: A Preliminary Report

  • Cho, Nam Su;Shim, Hee Seok;Nam, Ju Hyun;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.130-136
    • /
    • 2016
  • Background: A novel technique for the repair of tears of the upper subscapularis tendon-intraarticular knotless fixation-has been introduced recently. The purpose of this study was to evaluate the clinical and structural outcomes of arthroscopic intraarticular knotless fixation for the treatment of upper subscapularis tendon tears. Methods: We retrospectively analyzed the clinical and radiological outcomes of 27 patients who underwent arthroscopic intraarticular knotless fixation for upper subscapularis tendon tears. Finally, a total of 10 patients who could participate in at least a 6 month follow-up of magnetic resonance imaging evaluation and in a least 1-year follow-up on an outpatient basis were enrolled in our study. The mean age at the time of operation was 60.7 years, and the mean duration of follow-up was 14.7 months. Two patients had concomitant tears of the supraspinatus tendon and 8 patients had concomitant tears of the supraspinatus and the infraspinatus tendons. Results: The clinical and radiological outcomes improved after the patients had undertaken arthroscopic intraarticular knotless fixation. The mean visual analogue scale score for pain during motion improved from 6.7 preoperatively to 1.4 at the final follow-up (p<0.001). The mean Constant score improved from 59.3 preoperatively to 79.6 at the final follow-up, and the mean the University of California at Los Angeles score, from 21.7 to 30.2, respectively (p<0.001 and p<0.001). The upper subscapularis tendon tear was healed in every patient except one (90%), for the patient had suffered from a postoperative trauma that resulted in a retear. Conclusions: We found that arthroscopic intraarticular knotless fixation gives good clinical and structural outcomes for the repair of upper subscapularis tendon tears. Arthroscopic intraarticular knotless fixation provided such a reliable and efficient restoration of the subscapularis tendon footprint that we anticipate it will become a widely-used procedure for upper subscapularis tendon tears.

A Study of Legibility by Monitor Letter Color with an Eye Tracker (아이트래커를 이용한 모니터 글자 색상에 따른 가독성에 대한 연구)

  • Kim, Ha-Rim;Kim, Soo-Hyun;Shin, Dong-Min;Jeong, Hee-Young;Kim, Young-Gil;Kim, Tae-Hong;Seo, Jae-Myoung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.279-284
    • /
    • 2014
  • Purpose: This study will be a basic research providing data which can reduce eye strain using monitor and electric media by measuring legibility of text color on monitor. Methods: Total experimental subjects who don't have color anomaly and best corrected visual acuity was over 1.0 were 50 and their mean age was $22.83{\pm}1.47$. Reading speed test were carried out with 163 words and subjects who could read over 123 words were selected for legibility examination. Monitor background color was white and letter colors were black, blue, red, and yellow for the legibility examination. Results: In case of text color of black, blue, red, and yellow, Event duration(sec) was measured to 41.89, 42.89, 45.32, and 56.28, respevtively, and reading error (number) was measured to 1.94, 2.74, 3.36, and 5.14. Average of fixation duration(sec) was measured to 0.25, 0.26, 0.27, and 0.32. Conclusions: In this paper, event Duration, reading error and average of fixation duration which can measure the legibility was reduced in a sequence of black blue, red, and yellow.

Internal Fixation with Plate and Bone Graft of Mid-shaft Clavicle Nonunion (쇄골 간부 불유합의 자가골 이식술 및 금속판 내고정술)

  • Ko Sang-Hun;Cho Sung-Do;Park Moon-Soo;Woo Jong-Ken;Lee Chae-Chil;Jeong Ji-Young;Jung Kwang-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.1
    • /
    • pp.19-22
    • /
    • 2005
  • Purpose: The causes of twelve cases of the mid-shaft clavicle nonunion and the results of internal fixation with plate and bone graft were investigated. Materials and method: From August 1997 to March 2003, twelve cases of the mid-shaft clavicle nonunion were operated with internal fixation with plate and bone graft. The duration of follow-up was average 13 months. Results: The causes of the mid-shaft clavicle nonunion included severe associated injury, severe initial displacement of the fracture fragments and insecure fixation. All cases were operated with internal fixation with plate and bone graft. According to the factor for evaluations of results, using a rating scale of excellent (no apparent factors), good (one factor), fair (two factors), poor (more than three factors), the results showed 10 excellent, 1 good and 1 poor. Screw loosening was developed in only one case . Conclusion: The internal fixation with plate and bone graft of the mid-shaft clavicle nonunion after failed conservative treatment achieved excellent results and seemed to be the procedure of choice for mid-shaft clavicle nonunion.

Biomechanical Comparison of Spinal Fusion Methods Using Interspinous Process Compressor and Pedicle Screw Fixation System Based on Finite Element Method

  • Choi, Jisoo;Kim, Sohee;Shin, Dong-Ah
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.91-97
    • /
    • 2016
  • Objective : To investigate the biomechanical effects of a newly proposed Interspinous Process Compressor (IPC) and compare with pedicle screw fixation at surgical and adjacent levels of lumbar spine. Methods : A three dimensional finite element model of intact lumbar spine was constructed and two spinal fusion models using pedicle screw fixation system and a new type of interspinous devices, IPC, were developed. The biomechanical effects such as range of motion (ROM) and facet contact force were analyzed at surgical level (L3/4) and adjacent levels (L2/3, L4/5). In addition, the stress in adjacent intervertebral discs (D2, D4) was investigated. Results : The entire results show biomechanical parameters such as ROM, facet contact force, and stress in adjacent intervertebral discs were similar between PLIF and IPC models in all motions based on the assumption that the implants were perfectly fused with the spine. Conclusion : The newly proposed fusion device, IPC, had similar fusion effect at surgical level, and biomechanical effects at adjacent levels were also similar with those of pedicle screw fixation system. However, for clinical applications, real fusion effect between spinous process and hooks, duration of fusion, and influence on spinous process need to be investigated through clinical study.