• 제목/요약/키워드: Fixation, comminuted

검색결과 67건 처리시간 0.021초

Transosseous Tie Fixation Using Krackow Sutures and Bone Tunnels in a Comminuted Fracture of the Upper Pole of the Patella: A Case Report

  • Baik, Jong Seok
    • Journal of Trauma and Injury
    • /
    • 제34권4호
    • /
    • pp.305-308
    • /
    • 2021
  • Comminuted fractures of the patella mostly occur at the inferior pole and require appropriate reduction and fixation to restore the extensor mechanism. Conventional methods such as tension-band wiring are not enough to gain proper fixation strength. Numerous methods have been reported, including circumferential cerclage wiring, osteosynthesis, and suture anchors depending on the fracture pattern. Herein, the author reports a relatively rare case of a comminuted fracture of the upper pole of the patella, for which we used augmented Krackow sutures in the quadriceps and fixation with tying of the suture limbs through patellar bone tunnels. Satisfactory results were obtained in terms of reduction and extensor mechanism recovery.

Additional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture

  • Shin, Woo Jin;Chung, Young Woo;Kim, Seon Do;An, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • 제23권4호
    • /
    • pp.198-202
    • /
    • 2020
  • Simple clavicle fractures can achieve satisfactory results through conservative treatment, and the less frequency of nonunion. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.

하악골 복합 분쇄 골절의 치험례 (TREATMENT OF COMPOUND COMMINUTED MANDIBULAR FRACTURES)

  • 정종철;김건중;최재선;성대경;김호성;이계혁
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제20권2호
    • /
    • pp.101-105
    • /
    • 1998
  • Compound comminuted mandibular fracture is defined as the presence of multiple fracture lines with open wound resulting in many small pieces within the same area. The incidence of mandibular comminution is difficult to determine but reported as 2.7~18.6 % incidence among mandibular fractures. There are controversies in the treatment of mandibular comminuted fractures. Treatment of comminuted mandibular fracture has traditionally involved closed reduction in an effort to avoid stripping periostcum from the bony segments, but rigid internal rigid fixation is used more popular at present. The extent of comminution, displacement of bony fragments and patient general conditions are important factors in decision of the treatment methods. When significant bone displacement is present, it is necessary to reduce these comminuted fragments to an anatomic, pretraumatic relationship to restore facial form and function. In these cases, ORIF allows anantomic reduction of comminuted segments as well as pretraumatic occlusion. Gentle handling of the soft tissue, rigid fixation of bony fragments and adequate immobilization are essential for reducing the complications. This is the report the incidence, causes, complications and treatment of the patients who visited our department for compound comminuted mandibular fractures.

  • PDF

Clinical usefulness of fixation of absorbable implants with cyanoacrylate in comminuted fractures of the maxilla

  • Ju, Gang San;Son, Kyung Min;Choi, Woo Young;Cheon, Ji Seon
    • 대한두개안면성형외과학회지
    • /
    • 제20권4호
    • /
    • pp.233-238
    • /
    • 2019
  • Background: The open reduction of craniofacial bone fractures requires internal fixation using metal plates and screws, which have been considered the gold standard. However, metal implants pose a risk of palpation, protrusion, and foreign body reaction, and they may require an additional operation for removal. Recently, good results have been reported for absorbable implants which complement the disadvantages of metal implants. This study presents the results of using absorbable mesh, plates, and screws with cyanoacrylate for more accurate and firmer fixation of comminuted fractures of the maxilla. Methods: In total, 235 patients underwent operations for comminuted fractures of the maxilla. From January 2012 to December 2014, absorbable mesh and screws were used in 114 patients, while from January 2015 to December 2017, absorbable mesh, plates, and screws with cyanoacrylate were used in 121 patients. Open reduction of the bone fragments was performed, after which absorbable implants were accurately molded and fixed by screws. Results: All patients underwent postoperative computed tomography scans, which showed highly accurate reduction and firm fixation in the patients who underwent procedures using absorbable implants, screws, and cyanoacrylate. There were no postoperative complications or cases of abnormal facial contour. Conclusion: When absorbable implants and screws are used for maxillary fractures, no additional surgery to remove the metal plate is required. In addition, the use of cyanoacrylate enables accurate and firm fixation of the tiny bone fragments that cannot be fixed with screws.

하악골 분쇄골절의 치료 (TREATMENTS OF COMMINUTED MANDIBULAR FRACTURES)

  • 전우진;김수관;김현호;김학균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권1호
    • /
    • pp.71-75
    • /
    • 2005
  • This study evaluated retrospectively the treatment method and postoperative complications of communited mandibular fractures. We analyzed the clinical and radiologic data of 14 patients with the comminuted mandibular fractures who were admitted to Chosun University Dental Hospital from January 1998 to December 2003. We reviewed the cause of trauma, fracture sites, treatment methods, and postoperative complications. Thirteen patients (93%) had a successful treatment outcome without complications. Only one patient developed postoperative osteomyelitis requiring early plate removal and sequestrectomy. For the comminuted fractures of mandible, internal fixation using micro- or mini-plate was an effective treatment method with a low incidence of major complications.

원위 상완골 분쇄 골절의 수술적 치료 결과 (The Results of Surgical Treatment of Comminuted Fractures of Distal humerus)

  • 조남수;박성우;정기연;이용걸
    • Clinics in Shoulder and Elbow
    • /
    • 제8권2호
    • /
    • pp.97-104
    • /
    • 2005
  • Purpose: To report the results of surgical treatment of comminuted fractures of distal humerus and to identify factors that affect the results. Materials and Methods: Thirty-two patients who were treated with open reduction and internal fixation for comminuted fracture of distal humerus were enrolled. According to the AO classification, A2.3 was 1 case, A3.2, 2 cases, A3.3, 8 cases, B1.3, 1 case, B2.3, 1 case, C2.2, 5 cases, C2.3, 4 cases, C3.2, 3 cases and C3.3, 7 cases. As fixation technique, 17 cases were fixed by double plates, 4 cases by only K-wires, 4 cases by only screws, 3 cases by K-wires and screws and 4 cases by one plate and screws. The mean age at the time of the operation was 49 years(range, $19{\sim}77$ years). The mean follow-up period was 16 months(range, $8{\sim}51$ months). Results: At the last follow-up, the mean maximum flexion was $116.4^{\circ}\;(range,\;85{\sim}140^{\circ})$ and the mean loss of terminal extension was $11.8^{\circ}\;(range,\;0{\sim}40^{\circ})$. The average Mayo elbow performance score was $91.4^{\circ}\;(range,\;55{\sim}100^{\circ})$. Overall 29 cases(91%) showed good to excellent results. The mean range of motion of extraarticular and intraarticular fracture group was $105.5^{\circ}\;(range,\;65{\sim}140^{\circ})$ and $104^{\circ}\;(range,\;55{\sim}140^{\circ})$, respectively. The average elbow score of both groups was$93^{\circ}\;(range,\;70{\sim}100^{\circ})$ and $90.7^{\circ}\;(range,\;55{\sim}100^{\circ})$. Over 90% showed more than good results. 30 cases(94%) showed complete bony union but two cases, nonunion. One case of the nonunion cases underwent replating with bone graft as revision surgery and total elbow arthroplasty was performed in the other case. At the last follow-up, 27 patients(84.4%) showed subjective satisfaction. Conclusion: Open reduction and internal fixation with appropriate surgical technique for comminuted fractures of distal humerus showed good results, which were not affected by age at the time of operation, fixation methods and anterior transposition of the ulnar nerve. Transolecranon approach may be considered as good choice for intraarticular comminuted fractures of distal humerus.

Lumbo-sacro-pelvic Fixation Using Iliac Screws for the Complex Lumbo-sacral Fractures

  • Rhee, Woo-Tack;You, Seung-Hoon;Jang, Yeon-Gyu;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권6호
    • /
    • pp.495-498
    • /
    • 2007
  • Fractures of lumbo-sacral junction involving bilateral sacral wings are rare. Posterior lumbo-sacral fixation does not always provide with sufficient stability in such cases. Various augmentation techniques including divergent sacral ala screws, S2 pedicle screws and Galveston rods have been reported to improve lumbo-sacral stabilization. Galveston technique using iliac bones would be the best surgical approach especially in patients with bilateral comminuted sacral fractures. However, original Galveston surgery is technically demanding and bending rods into the appropriate alignment is time consuming. We present a patient with unstable lumbo-sacral junction fractures and comminuted U-shaped sacral fractures treated by lumbo-sacro-pelvic fixation using iliac screws and discuss about the advantages of the iliac screws over the rod system of Galveston technique.

Kirschner Wire Fixation for the Treatment of Comminuted Zygomatic Fractures

  • Kang, Dai-Hun;Jung, Dong-Woo;Kim, Yong-Ha;Kim, Tae-Gon;Lee, JunHo;Chung, Kyu Jin
    • 대한두개안면성형외과학회지
    • /
    • 제16권3호
    • /
    • pp.119-124
    • /
    • 2015
  • Background: The Kirschner wire (K-wire) technique allows stable fixation of bone fragments without periosteal dissection, which often lead to bone segment scattering and loss. The authors used the K-wire fixation to simplify the treatment of laborious comminuted zygomatic bone fracture and report outcomes following the operation. Methods: A single-institution retrospective review was performed for all patients with comminuted zygomatic bone fractures between January 2010 and December 2013. In each patient, the zygoma was reduced and fixed with K-wire, which was drilled from the cheek bone and into the contralateral nasal cavity. For severely displaced fractures, the zygomaticofrontal suture was first fixated with a microplate and the K-wire was used to increase the stability of fixation. Each wire was removed approximately 4 weeks after surgery. Surgical outcomes were evaluated for malar eminence, cheek symmetry, K-wire site scar, and complications (based on a 4-point scale from 0 to 3, where 0 point is 'poor' and 3 points is 'excellent'). Results: The review identified 25 patients meeting inclusion criteria (21 men and 4 women). The mean age was 52 years (range, 15-73 years). The mean follow up duration was 6.2 months. The mean operation time was 21 minutes for K-wire alone (n=7) and 52 minutes for K-wire and plate fixation (n=18). Patients who had received K-wire only fixation had severe underlying diseases or accompanying injuries. The mean postoperative evaluation scores were 2.8 for malar contour and 2.7 for K-wire site scars. The mean patient satisfaction was 2.7. There was one case of inflammation due to the K-wire. Conclusion: The use of K-wire technique was associated with high patient satisfaction in our review. K-wire fixation technique is useful in patient who require reduction of zygomatic bone fractures in a short operating time.

관절경하 AO 무두 압박 나사를 이용한 견갑골 전방 관절와 분쇄 골절의 치료 - 증례 보고 - (Treatment of Anterior Glenoid Rim Fracture with Comminuted Fragment Using Arthroscopic Reduction and AO Headless Compression Screw Fixation - A Case Report -)

  • 김형식;고일현;김성국;천용민;김성재;강호정
    • Clinics in Shoulder and Elbow
    • /
    • 제14권1호
    • /
    • pp.94-98
    • /
    • 2011
  • 목적: 견갑골 전방 관절와 분쇄 골절에 대해 관절경하 정복 및 AO 무두 압박 나사를 이용하여 골편을 고정한 증례를 보고하고자 한다. 대상 및 방법: 31세 남자로 내원 2주 전 추락 후 발생한 좌측 견관절의 전방 관절와 분쇄 골절에 대하여 관절경하에서 골절을 정복한 후, 표준 전상방 삽입구를 통해 1.1 mm K 강선을 가이드핀으로 삽입하고 AO 무두 압박 나사로 골편을 고정하였다. 결과: 수술 후 12개월째 견관절의 운동 범위는 정상 범위로 회복 되었으며, 골절은 유합을 얻었고 일상 생활에 불편감은 없었다. 결론: AO 무두 압박 나사는 나사의 길이가 다양하여 작은 관절와 골편에 사용하기 적합하고, 가이드 핀의 길이가 상대적으로 짧으나 1.1 mm K 강선으로 대체가 가능하며, 나사 돌리개 (screw driver)나 천공기 (drill bit) 등의 동반 기구의 길이가 길어 비교적 깊은 위치의 견갑과 골절의 고정에 사용하기 편리하여 관절경적 고정술 시 유용하게 이용할 수 있을 것으로 생각된다.