• 제목/요약/키워드: Five fingers

검색결과 56건 처리시간 0.018초

유연한 인간형 로봇 손의 설계 (Design of a Dexterous Anthropomorphic Robot Hand)

  • 지호준;이상헌;최병준;최혁렬
    • 대한기계학회논문집A
    • /
    • 제30권4호
    • /
    • pp.357-363
    • /
    • 2006
  • According to the study of grasping of the human hand, it is noted that the metacarpal link of the thumb plays the key role in power grasping. Also the face of fingertip can be discriminated into five parts depending on the grasping modalities such as pinch grasp, fingertip grasp and power grasp. In this paper, the design of the anthropomorphic robot hand which has a thumb and three fingers is proposed. A difference of SKKU hand II from the previous gripperlike robot hand is that the metacarpal bone is connected between the thumb and the palm. This thumb mechanism is specially designed to get the degree of freedom which can realize flexible motions relative to objects. Based on the analysis, the hand mechanism is developed. Since the driving circuits for the hand are embedded in the hand, only the communication lines supporting CAN protocol with DC power cable are necessary as the input. A new robot is manufactured and feasibility of the hand is validated through preliminary experiments.

상완 신경총 손상시 건측 제 7번 경추신경 전이술 후 건측 상지의 신경 변화 (Neurologic Changes in the Donor Limb after Contralateral-C7 Transfer in Brachial Plexus Injury)

  • 한정수;차재룡;신동준;임양진
    • Archives of Reconstructive Microsurgery
    • /
    • 제10권1호
    • /
    • pp.7-11
    • /
    • 2001
  • Purpose : To evaluate the neurologic abnormalities in the donor limb after contralateral C7 transfer in brachial plexus injury. Materials and Methods : From August 1996 to December 1999, five patients with brachial plexus injury were treated with contralateral C7 nerve root transfer. The average follow up was 16 months(range, 5 to 36 months). The clinical findings were assessed using the British Medical Research Council Grading System, and also measured grip power, pinch power of hand and two point discrimination of the fingers. Results : We had no difference in shoulder abduction and elbow flexion after contralateral C7 transfer. The grip and pinch strength were recovered within 4weeks. Sensory loss occurred in all patients and was noted to be more severe on index and middle finger. Four patients recovered within 2 weeks, one continued till one year. Subjective numbness and pain on percussion minimally persisted until last follow-up. Conclusion : The division of the C7 nerve root resulted in minimal and temporary functional deficit in the donor upper limb.

  • PDF

Reconstruction of Distal Phalangeal Soft Tissue Defects with Reverse Homodigital Artery Island Flap

  • Kim, Byung-Gook;Han, Soo-Hong;Lee, Ho-Jae;Lee, Soo-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • 제23권2호
    • /
    • pp.65-69
    • /
    • 2014
  • Purpose: Soft tissue reconstruction is essential for recovery of finger function and aesthetics in any traumatic defect. The authors applied a reverse homodigital artery island flap for soft tissue defect on distal part of digits. The aim of this study is to evaluate the efficacy of the procedure. Materials and Methods: Seven cases of soft tissue defects of finger tip were included in this study. There were six male and one female, mean age was 43 years and mean follow-up period was 38 months. The length of flaps ranged from 2.0 to 2.5 cm and width ranged from 1.0 to 2.0 cm. Flap survival, postoperative complications were evaluated. Results: All flaps survived without loss. Donor sites were repaired with primary closure in five cases and skin graft in two cases. None of the patients showed significant complications and their average finger motion was $255^{\circ}$ in total active motion at the last follow-up. Conclusion: The authors suggest that the reverse homodigital artery island flap could be a versatile treatment option for the soft tissue defect on distal part of digits.

선천성 삼첨판 폐쇄증 (수술 2례 보고) (Tricuspid Atresia: Two Cases of Successful Palliative Surgery)

  • 김주현
    • Journal of Chest Surgery
    • /
    • 제6권1호
    • /
    • pp.63-68
    • /
    • 1973
  • Two patients operated upon for tricuspid atresia by Glenn operation are presented. They were five years old and four years old females who were cyanotic shortly after birth, and remained cyanotic. On physical examination, cyanosis on digits and lips, clubbing of fingers, thrill and grade III systolic murmur on 4th I.C.S. along left sternal border were noted. In the first case, chest roentgenograms showed normal pulmonary markings, and the electrocardiogram was interpreted as showing left ventricular hypertrophy with left axis deviation and peaked P-wave in lead IL Right heart catheterization showed high pressure in right atrium and the catheter tip was easily inserted into the left atrium through septal defect. In the second case, chest roentgenograms showed cardiomegaly with sparse pulmonary vascular markings and narrowed vascular pedicle, and the electrocardiogram showed left ventricular hypertrophy with some element of right atrial hypertrophy. Angiocardiogram showed changes characteristic of tricuspid atresia, including "right ventricular window" The findings of right heart catheterization were similar to those of first case. On the basis of these observations, they were diagnosed as tricuspid atresia, and Glenn operation was performed. Normal position of great vessels combined with ventricular septal defect and pulmonary stenosis were noted on the first case, and on second case, transposition of great vessels was additional finding. Postoperative course was uneventful and favorable outcome was obtained.

  • PDF

측와위로 시행한 견관절 관절경 후에 동시에 발생한 전방 및 후방 골간 신경 증후군 - 증례보고 - (Simultaneous Anterior and Posterior Interosseous Nerve Syndrome Following Shoulder Arthroscopy in the Lateral Decubitus Position - Case Report -)

  • 서재성;김지훈;강동화
    • Clinics in Shoulder and Elbow
    • /
    • 제16권2호
    • /
    • pp.148-152
    • /
    • 2013
  • 관절 관절경으로 수술적 치료를 시행한 후 전방 및 후방 골간 신경 증후군이 동시에 발생한 1예를 보고하고자 한다. 45세 남자 환자가 좌측 견관절의 불안정성으로 견관절 관절경 수술을 시행받았다. 전신 마취하 우측 측와위 자세에서 전완부를 신전한 상태에서 견인 장치를 부착한 상태로 2시간 동안 수술을 시행하였다. 1주일 후 환자는 좌측 전완부 동통, 수지의 신전력 및 무지와 인지의 심수지 굴근력의 저하로 외래를 방문하였다. 경과 관찰하였으나 증상이 지속되어 전방 골간 신경에 대해서는 신경 탐색술을 시행하였고 후방 골간 신경에서는 모래 시계 모양의 협착 소견이 발견되어 병변 절제 후 신경 외막 봉합술을 시행하였다. 수술 후 약 5개월간 외래에서 경과 관찰하였다. 신경 탐색술을 시행하고 3개월 후 총수지 신근의 기능이 회복하기 시작하였으며, 점차 회복하여 신경 탐색술 후 5개월째 증상이 완전히 회복되었다. 견관절 관절경 수술 후 전방 및 후방 골간 신경 증후군의 발생은 드물지만 견인 장치 및 수술 중 자세에 의해 유발될 수 있다. 따라서 견인 장치 부착 및 수술 자세에 대해 술자의 주의가 필요하다고 생각한다.

Prevalence of Work-related Musculoskeletal Disorders in Auto-mission Assembly Plant Workers

  • Min, Seung Nam;Subramaniyam, Murali;Kim, Dong-Joon;Park, Se Jin;Lee, Heeran;Lee, Ho Sang;Kim, Jung Yong
    • 대한인간공학회지
    • /
    • 제34권4호
    • /
    • pp.293-302
    • /
    • 2015
  • Objective: This study was performed to investigate the prevalence of musculoskeletal disorders in auto workers of a mission assembly plants. Background: Most studies of musculoskeletal disorders have used car assembly line workers as their participants. However, little research has been done on musculoskeletal disorders afflictions of mission assembly line workers. Method: Through a focus group interview with an ergonomist and a manager at a mission assembly plant site, a questionnaire was developed for musculoskeletal disorders. The questionnaire consisted of five parts, demographic factors, musculoskeletal disorder symptoms, and musculoskeletal disorder experiences; 137 workers participated in this survey. The surveys were analyzed by correlation and Chi-squared analysis. Results: Musculoskeletal disorder symptoms and serious pain were reported in the neck, shoulder, back, and fingers. These problems were statistically related to various demographic factors, such as age, stature, stretching, and work satisfaction. Conclusion: Treatment of musculoskeletal disorders should consider the workers' traits. If there is no specific cause of the pain, developing stretches and exercises before and after work should be applied to prevent musculoskeletal disorders. Application: The results of this study can be used to develop guidelines to prevent injury in auto workers at mission assembly plants.

Osseointegrated Finger Prostheses Using a Tripod Titanium Mini-Plate

  • Manrique, Oscar J.;Ciudad, Pedro;Doscher, Matthew;Torto, Federico Lo;Liebling, Ralph;Galan, Ricardo
    • Archives of Plastic Surgery
    • /
    • 제44권2호
    • /
    • pp.150-156
    • /
    • 2017
  • Background Digital amputation is a common upper extremity injury and can cause significant impairment in hand function, as well as psychosocial stigma. Currently, the gold standard for the reconstruction of such injuries involves autologous reconstruction. However, when this or other autologous options are not available, prosthetic reconstruction can provide a functionally and aesthetically viable alternative. This study describes a novel technique, known as a tripod titanium mini-plate, for osseointegrated digit prostheses, and reviews the outcomes in a set of consecutive patients. Methods A retrospective review of patients who underwent 2-stage prosthetic reconstruction of digit amputations was performed. Demographic information, occupation, mechanism of injury, number of amputated fingers, and level of amputation were reviewed. Functional and aesthetic outcomes were assessed using the quick disabilities of the arm, shoulder, and hand (Q-DASH) scale and a visual analog scale (VAS) score, respectively. In addition, complications during the postoperative period were recorded. Results Seven patients were included in this study. Their average age was 29 years. Five patients had single-digit amputations and 2 patients had multiple-digit amputations. Functional and aesthetic outcomes were assessed using the Q-DASH score (average, 10.4) and VAS score (average, 9.1), respectively. One episode of mild cellulitis was seen at 24 months of follow-up. However, it was treated successfully with oral antibiotics. No other complications were reported. Conclusions When autologous reconstruction is not suitable for digit reconstruction, prosthetic osseointegrated reconstruction can provide good aesthetic and functional results. However, larger series with longer-term follow-up are required in order to rule out the possibility of other complications.

내반주 변형에 의한 지연성 척골 신경 마비 (Tardy Ulnar Nerve Palsy due to Cubitus Varus Deformity)

  • 전인호;김풍택;박병철;인주철
    • Clinics in Shoulder and Elbow
    • /
    • 제5권1호
    • /
    • pp.29-36
    • /
    • 2002
  • Purpose : Cubitus varus deformity has been reported to cause ulnar neuropathy. We present five cases of tardy ulnar nerve palsy due to cubitus vus and analyzed the factors related to the nerve plasy caused by the deformity. Materials and Methods : Three men and two women were reviewed retrospectively and the mean age of the patients were 26 (range, 14-38). The average interval from initial fracture to nerve palsy was 19 years (8-32 years). The severity of symptoms, according to McGowan's classification, was grade I of 2 patients, grade Ⅱ of 3 patients. Carrying angle was an average of 18。 (30° -45° ). Internal rotation angle measured by Yamamoto's method was an average of 33° (30° -45° ). Results ㆍ The mean follow-up period was 53 months (35-70 months). Elbow pain and numbness of the fingers were relieved shortly after surgery. It revealed that anterior subluxation of the nerve due to internal rotation deformity and compression of the nerve between the medially shifted medial head of triceps and the medial epicondyle. Conclusion : The major entrapment point of the nerve is the fibrous band between the two heads of the flexor carpi ulnaris. The severe internal rotation deformity may contribute the cause of tardy ulnar nerve palsy in cubitus varus deformity.

FBG를 이용한 맥진 시스템 개발 (Development of the pulse analyzing system using FBG)

  • 전영주;이전;유현희;이재훈;이시우;김종열
    • 한국한의학연구원논문집
    • /
    • 제13권3호
    • /
    • pp.105-110
    • /
    • 2007
  • This work reports the pulse diagnosis system using FBG sensors which can display pulse signals detected while oriental medical doctors are conducting pulse diagnoses and simultaneously pressing the sensors by three fingers. Each optical fiber has five FBG sensing units fabricated in 2 mm width and 2 mm inter-sensor spacing. Three optical fibers with the FBG units in the parallel line configuration are then placed on each finger-pressing region and thus overall 9 fibers are used for the pulse measurements on the so-called "chon", "gwan", and "ch대k". A fixture holding the optical fiber arrays is able to adjust the height of the FBG sensing units while placing the fibers on the wrist. The pulse signals detected by the FBG sensors from chon, kwan, and chuk have been analyzed using 4 channel spectrum analyzer connected to the optical fibers. The measured pulse signals exhibit variations due to the nonuniform pressure distributions applied. resulting in the differences in the detected pulse signals between fiber lines. However. this work is the first step towards objective and quantitative analyses of the pulse diagnosis in oriental medicine which has traditionally been performed on subjective basis. Future works will be devoted to improving sensor stability, developing the way applying pressure and algorithms reporting the objective classification of the pulse status from systemic measurements using the sensors instead of relying on the clinicians' diagnoses subjectively performed. A successful pulse diagnosis system emerging in the future is expected to contribute to education as well as promoting pulse diagnosis in oriental medicine to the scientific research area.

  • PDF

제 2족지 근위지관절 유리피판술을 이용한 수지 근위지관절 재건 후 시행한 건박리술 (Tenolysis after the reconstruction of PIP joint of the finger using second toe PIP joint free flap)

  • 박형준;이동철;김진수;기세휘;노시영;양재원
    • Archives of Plastic Surgery
    • /
    • 제36권4호
    • /
    • pp.450-457
    • /
    • 2009
  • Purpose: The second toe PIP joint free flap is a method of reconstruction used for abnormalities of the PIP joint of the finger. We report the results of the additional tenolysis in patients with a difference between passive ROM and active ROM after second toe PIP joint free flap. Methods: From March 2001 to July 2008, tenolysis was performed in patients with a difference in their active and passive ROM after second toe PIP joint free transfer, performed on 14 fingers. We performed a retrospective analysis of the medical records, noting the clinical and radiological findings. In addition, we measured the preoperative and postoperative range of motion of the PIP joint. Results: The average active ROM was $22.5^{\circ}$ at the three months after the joint transfer surgery, and was $38^{\circ}$ after additional tenolysis between five months and twelve months after the joint transfer. Conclusions: Additional tenolysis, after the second toe PIP joint free flap, might be a good option for improved results in patients with difference in active and passive ROM of a transferred PIP joint.