시베리아 산불이 2003년 봄철 동아시아 오존 농도에 끼치는 영향 연구 (A study of the Effects of Siberian Wildfires on Ozone Concentrations over East Asia in Spring 2003)

  • 박록진;정재인;윤대옥
    • 대기
    • /
    • 제19권3호
    • /
    • pp.227-235
    • /
    • 2009
  • Global climate warming induced by long-lived greenhouse gases is expected to cause increases in wildfire frequencies and intensity in boreal forest regions of mid- and high-latitudes in the future. Siberian forest fires are one of important sources for air pollutants such as ozone and aerosols over East Asia. Thus an accurate quantification of forest fire influences on air quality is crucial, in particular considering its higher occurrences expected under the future warming climate conditions. We here use the 3-D global chemical transport model (GEOS-Chem) with the satellite constrained fire emissions to quantify Siberian fire effects on ozone concentrations in East Asia. Our focus is mainly on spring 2003 when the largest fires occurred over Siberia in the past decade. We first evaluated the model by comparing to the EANET observations. The model reproduced observed ozone concentrations in spring 2003 with the high $R^2$ of 0.77 but slightly underestimated by 20%. Enhancements in seasonal mean ozone concentrations were estimated from the difference in simulations with and without Siberian fires and amounted up to 24 ppbv over Siberia. Effects of Siberian fires also resulted in 3-10 ppbv incresases in Korea and Japan. These increases account for about 5-15% of the ozone air quality standard of 60 ppbv in Korea, indicating a significant effect of Siberian fires on ozone concentrations. We found however that possible changes in regional meteorology due to Siberian fires may also affect air quality. Further study on the interaction between regional air quality and meteorology is necessary in the future.

한국 . 일본 . 미국의 화재발생실태에 대한 비교분석 (1) 화재발생추이 (A Study on Fire Data Analysis in Korea, Japan and USA (1) Number of Fires and Fire Trends)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제18권3호
    • /
    • pp.74-94
    • /
    • 2004
  • 한국ㆍ일본ㆍ미국의 화재발생 실태를 분석해본 바, 미국은 1977년 3,264,500건에서 2002년 1,687,500 건으로 화재 발생건수가 크게 감소하는 경향에 있고, 일본은 1973년 73,072건을 정점으로 20년이상 6만건 전후의 화재가 발생하고 있으나, 우리나라의 경우에는 1980년 5,438건이던 화재가 급격하게 증가하여 2001년 36,169건까지 발생하였다가 2003년 31,372건의 화재가 발생하였다. 또한 화재통계 처리요령과 화재통계 보고서에 대해서도 분석해본 바, 우리나라가 가장 뒤떨어져 있으며, 화재발생건수의 정확한 산정 등 화재통계의 신뢰성을 확보하기 위한 화재통계 분류의 구체화 및 체계화의 필요성을 확인하였다.

GIS를 이용한 산불발생위험지역 구분 (Classification of Forest Fire Occurrence Risk Regions using GIS)

  • 이시영;안상현;원명수;이명보;임태규;신영철
    • 한국지리정보학회지
    • /
    • 제7권2호
    • /
    • pp.37-46
    • /
    • 2004
  • 산불로 인한 재해를 미연에 방지하고 피해를 저감하기 위해서는 산불발생위험지역을 사전에 파악하여 예방대책을 세울 필요가 있다. 따라서 본 연구에서는 산불발생인자에 따른 산불발생위험지역을 구분하고자 경상북도 의성군에서 발생한 산불피해지역에 대하여 임상, 지형 등에 대하여 조사하였다. 조사된 요인들 간 독립성 유무를 상관분석을 이용하여 산불발생과 관련 있는 7개의 주제도를 선정하였으며, 선정된 주제도률 조건부확률과 지리정보시스템을 이용하여 산불발생확률을 계산하였다. 계산된 산불발생확률을 20개 등급으로 지수화하여 산불발생위험지역을 구분하였다.

  • PDF

FIRES IN REAL SCENARIOS

  • Ghosh, B-K
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.439-449
    • /
    • 1997
  • Studies have been carried out to determine the effect of sprinklers on fires typical of a number of occupancies including simulated of office furniture, supermarkets, carpet displays, libraries, video stores and liquor stores. After surveys of actual fire loads, the experiments were conducted in a specially designed sprinklered fire-calorimeter with a collecting hood 6 m x6 m leading to a vertical duct 1 m in diameter. Details of the rig are given elsewhere [1]. Only well ventilated fires were studied. Rate of heat release and production of various toxic chemicals were monitored during the tests. Both sprinklered and unsprinklered fires were used. The results were used to establish the unsprinklered burning behaviour and the fire-control effects of sprinklers. Before sprinkler operation, the rate of fire growth could be modelled as 12_fires as given in NFPA 92B (1991 Edition) [2]. It was found that operation of sprirnklers controlled but did not extinguish the fires. This was expected as parts of the fire load were shielded from the spray. Also there were significant increases in the concentration of carbon monoxide when the sprinklers operated. Sprinklers had little effect on the concentrations of other toxic products measured. The results from the tests were extrapolated to large single storey buildings for the same occupancy classes and the results used to compare the required and the available escape times for different occupancies, particularly whether the use of sprinklers would improve the chances of escape from those premises. It was found that in most of the cases studied, adequate escape times will be available without any special measures. For very rapid fire growths, however, special measures, such as availability of trained staff may be needed. Standard response sprinklers will have little impact.

  • PDF

기후변화 취약성 평가 분석도구 개발에 관한 연구: 충남지역 산불 취약성을 중심으로 (Development of a Climate Change Vulnerability Assessment Analysis Tool: Based on the Vulnerability Assessment of Forest Fires in Chungcheongnam-do)

  • 윤수향;이상신
    • 한국기후변화학회지
    • /
    • 제8권3호
    • /
    • pp.275-285
    • /
    • 2017
  • Chungnam region has established and executed the 2nd Climate Change Adaptation Initiative Execution Plan (2017~2021) based on the Framework Act on Low Carbon, Green Growth. The Execution Plan is established based on the results of climate change vulnerability assessment using the CCGIS, LCCGIS, and VESTAP analysis tools. However, the previously developed climate change vulnerability assessment tools (CCGIS, LCCGIS, VESTAP) cannot reflect the local records and the items and indices of new assessment. Therefore, this study developed a prototype of climate change vulnerability assessment analysis tool that, unlike the previous analysis tools, designs the items and indices considering the local characteristics and allows analysis of grid units. The prototype was used to simulate the vulnerability to forest fires of eight cities and seven towns in Chungcheongnam-do Province in the 2010s, 2020s, and 2050s based on the RCP (Representative Concentration Pathways) 8.5 Scenario provided by the Korea Meteorological Administration. Based on the analysis, Chungcheongnam-do Province's vulnerability to forest fires in the 2010s was highest in Seocheon-gun (0.201), followed by Gyeryong-si (0.173) and Buyeo-gun (0.173) and the future prospects in the 2050s was highest in Seocheon-gun (0.179), followed by Gyeryong-si (0.169) and Buyeo-gun (0.154). The area with highest vulnerability to forest fires in Chungcheongnam-do Province was Biin-myeon, Seocheon-gun and the area may become most vulnerable was Pangyo-myeon, Seocheon-gun. The prototype and the results of analysis may be used to establish the directions and strategies in regards to the vulnerability to wild fires to secure each local government's 2nd execution plan and attainability.

산불에 의한 지하수 토양 환경오염과 방사성 물질 분포 및 거동 영향 고찰 (Groundwater and Soil Pollution Caused by Forest Fires, and Its Effects on the Distribution and Transport of Radionuclides in Subsurface Environments: Review)

  • 배효진;정성욱;오정선;정진아
    • 자원환경지질
    • /
    • 제56권5호
    • /
    • pp.501-514
    • /
    • 2023
  • 산불은 연소 과정에서 다양한 오염물질을 배출하여 심각한 환경 문제를 초래할 수 있다. 최근 지구 온난화와 기후변화의 영향으로 전 세계적으로 산불의 규모와 빈도가 증가하여 환경에 미치는 영향 역시 급증할 것으로 예상된다. 한국은 산불 발생이 빈번한 동해안 지역에 원자력 발전소가 위치하고 있어, 중대 사고에 대비하여 산불 환경에서 방사성 핵종의 거동 특성에 대한 이해가 요구된다. 본 리뷰 논문에서는 산불이 지하수 토양 환경에 가져오는 변화와 오염 특성을 검토하고, 산불로 변화된 지하수 토양 환경에서의 방사성 핵종 거동을 고찰하였다. 특히, 변화된 지중환경의 여러 특성 중 방사성 핵종의 거동에 영향을 미칠 수 있는 요인들을 고려하였으며, 보다 구체적인 메커니즘 이해를 위해 산불이 초래하는 지하수 토양 환경 변화와 오염에 대한 연구의 필요성을 기술하였다.

전기자동차 화재 대응을 위한 제도적 개선 방안 연구: 서울시 사례를 중심으로 (A Study of Institutional Improvements for Responding to Electric Vehicle Fires: Focusing on the Case of Seoul)

  • 박남권;함승희
    • 한국재난정보학회 논문집
    • /
    • 제20권1호
    • /
    • pp.32-39
    • /
    • 2024
  • 연구목적과 방법: 전기차 화재에 대한 대응력을 향상시키기 위해 제도적 개선방안을 제시하고자 한다. 이를 위해 서울시를 중심으로 전기차 보급 및 화재 발생 현황, 관련 법 제도를 살펴보았다. 연구결과: 전기차 관련 상위법령 및 조례는 보급정책만 중심적으로 규정되어 있어 전기차 화재에 대해 실질적인 화재 대응 방안이 없는 상황이다. 각 자치단체별로 동일한 규정을 적용하기 위해서는 상위법령에서 소방 및 안전 시설에 대한 기준 정립과 제도 확립이 필요하다. 결론: 전기차 화재 특성을 고려한 소방 및 안전시설 설치 기준을 정하고 관련 제도의 개선을 통해 전기자동차 화재에 대한 시민들의 우려를 잠식시키는 것이 궁극적으로 전기차 보급률을 향상시키는 효과로 이어질 것이다.

옥내배선, 콘센트 및 플러그 개선을 통한 전기화재 예방대책 (Electrical and Fire Prevention Measures through Improvement of Indoor Wiring, Outlets and Plugs)

  • 정성효;안희석;이용수;김창은
    • 한국건설안전학회 논문집
    • /
    • 제1권1호
    • /
    • pp.31-39
    • /
    • 2018
  • 국내에서 발생하는 화재사고 중 약 20%가 전기설비에서 기인한 화재로 확인되고 있다. 복잡하고 대형화되어있는 건축물에서 전기화재는 재산 피해와 인명 피해가 증가하면서 대형화하는 양상으로 발생하고 있다. 여러 가지 전기화재의 원인 중 누전에 의한 발화가 약 71.5%를 차지하고 있고, 전기설비별 분류에서는 배선 및 배선기구에서 발생하는 화재가 약 38.3%를 차지하고 있다. 본 연구의 목적은 현재 사용되고 있는 옥내배선 형태를 개선하여 누전으로 인한 전기화재를 예방하는 방법을 제시하고, 배선기구에서 범용 되고 있는 콘센트와 플러그를 개선하여 배선기구에서 발생하는 화재를 예방하는 근원적 방안을 찾고자 한다. 본 연구를 통해서 제시되는 전기화재 예방대책은 전기화재의 근원적 원인을 제거하여 많은 인명과 재산을 보호하는 대책으로 활용될 수 있을 것으로 기대된다.

Proposal for an emergency evacuation method in hotel fires

  • Muraoka, Tetsuya
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.85-89
    • /
    • 1992
  • This report his discussed emergency evacuation in hotel fires and proposed an integrated system of emergency evacuation. By using "A New Type of the Computerized Emergency Evacuation System" all guests will be able to quickly and safety escapes the fire. the fire.

  • PDF

철도터널에서의 화재시 발생되는 연기 온도/발생량 계산 (Calculation of Smoke Temperature/Volume Folw rate in Tunnel Fires)

  • 박원희;장용준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1218-1222
    • /
    • 2007
  • Under various tunnel fires, smoke average temperature and volume flow rate in a tunnel fire are calculated. To obtain realistic results, enthalpy of smoke which composites combustion gases and entrainment air is calculated from curvefit polynomials by temperature.

  • PDF