• 제목/요약/키워드: Firefighting System

검색결과 94건 처리시간 0.024초

음압격리병실에서의 기침 토출입자의 입경에 따른 확산 및 침적에 대한 수치해석 연구 (A Numerical Study on Coughed Particle Dispersion and Deposition in Negative Pressure Isolation Room according to Particle Size)

  • 정민지;홍진관
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권2호
    • /
    • pp.37-44
    • /
    • 2018
  • Purpose: This study investigates the influences of coughing direction and healthcare worker's location on the transport characteristics of coughed particles in airborne infection isolation room (AIIR), which is commonly called negative pressure isolation room, with a downward ventilation system. Methods: Computational Fluid Dynamics (CFD) was used to simulate the airflow and for tracing the behavior of particles. Results: The results show that the airflow pattern and coughing direction have a significant influence on the characteristics of particle dispersion and deposition. When healthcare workers are in the isolation room with the patient who is lying on the bed, it is recommended to be located far from the anteroom to reduce the exposures from infectious particles. And when the patient is lying, it is more effective in removing particles than when the patient is in Fowler's position. Although it is an isolation room that produces unidirectional flow, coughing particles can spread to the whole room and a large number of particles can be deposited onto patient, bed, side rails, healthcare worker, ceiling, floor, and sidewall. Implications: Following the patients' discharge or transfer, terminal cleaning of the vacated room, furniture, and all clinical equipment is essential. Also, it is necessary to establish detailed standard operating procedure (SOP) in order to reduce the risk of cross-contamination.

다중이용업소의 화재예방을 위한 빅데이터 기반의 탐색적 연구 (Exploratory study on the based on big data for fire prevention of multiple shops)

  • 전병관;이성원
    • 산업융합연구
    • /
    • 제16권4호
    • /
    • pp.27-32
    • /
    • 2018
  • 본 연구는 다수의 인명피해가 우려되는 다중이용업소의 화재예방을 위하여 국민안전처의 예방소방행정 통계자료와 소방청의 국가화재정보센터 데이터를 기반으로 다중이용업소의 화제를 줄일 수 있는 방안에 대해 탐색적으로 접근을 시도하였다. 본 연구는 소방청의 예방소방행정 통계자료를 활용하여 다중이용업소 소방안전교육의 효과성에 초점을 맞추고 분석을 수행하였다. 분석 결과를 통해 소방안전교육이 실제 화재예방에 있어서 실효성을 가지지 못한다는 것을 유추해낼 수 있었다. 선행 연구들을 통해 그 원인이 소방안전교육의 운영 미흡이라는 것을 찾아내었으며 이를 통해 체계적인 소방안전교육 시스템 개발이라는 개선안을 도출하였다.

Design and Control of a Firefight Cannon Manipulator Applying Sliding Mode Control

  • Vu, Mai The;Choi, Hyeung-Sik;Kang, Hyeon-Seung;Bae, Jae-Hyeon;Joo, Moon-G.;Joo, Yeong-do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권5호
    • /
    • pp.554-562
    • /
    • 2015
  • This paper describes an analysis of an architecture and control system of a firefighting cannon manipulator (FCM) composed of two joint axes and one water-shooting actuator. Because the orienting FCM motion is disturbed by the reaction force from water shooting, the water shooting force has been modeled for robust control. The dynamics model of the manipulator has been set up including the external force of water-shooting reaction on the manipulator. A PD Controller and Sliding Mode Controller have been designed and their performance been tested through simulation to track a desired trajectory under the disturbance of a water-shooting reaction. The simulation shows that the performance of the Sliding Mode Controller is better than that of the PD controller.

다수의 사상자 발생 재난 대응체계의 개선방안에 관한 연구 (A Study on the Improvement of Disaster in Multiple Casualties)

  • 박경진
    • 한국산업융합학회 논문집
    • /
    • 제26권2_2호
    • /
    • pp.273-278
    • /
    • 2023
  • In this study, We conducted a survey for improvement about disaster in multiple casualties. Results, It was checked out many problems that Triage is inconvenience in using and damaging. And it was turned out that firefighting resources are not being put efficiently in the right place. Therefore, We are proposed that expansion of education and training opportunities, Location system of emergency activity resource in using App, Cope with a multiple casualties in using QR Code.

Long Jet Monitor의 소화수 분사 거리에 대한 유동 해석적 연구 (A Study of Computational Fluid Dynamics Analysis for the Water Spray Distance of Long Jet Monitor)

  • 조재상
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.907-913
    • /
    • 2023
  • Currently, the sprinkler method is widely used as an initial suppression method in existing firefighting systems. However, this method can cause significant damage to both equipment and facilities in the hydration area. To minimize this damage, fire extinguishing monitors are being developed that can spray fire extinguishing water directly at the point of fire. These monitors are installed on the top floor of the ship, such as the Living Quarter and Ventilation System. While conventional fire extinguishing monitors focus on lightweight research with a short spray port and require a spray distance of about 40 to 45m, recent developments necessitate a longer spray port, similar to a water cannon, requiring a spray distance of about 70 to 75m. This study aims to predict the injection distance of both the existing ship-installed fire extinguisher and the long spray port fire extinguisher through hydrodynamic computer analysis, and to determine whether the injection distance has increased.

Compact near-eye display for firefighter's self-contained breathing apparatus

  • Ungyeon Yang
    • ETRI Journal
    • /
    • 제45권6호
    • /
    • pp.1046-1055
    • /
    • 2023
  • We introduce a display for virtual-reality (VR) fire training. Firefighters prefer to wear and operate a real breathing apparatus while experiencing full visual immersion in a VR fire space. Thus, we used a thin head-mounted display (HMD) with a light field and folded optical system, aiming to both minimize the volume for integration in front of the face into a breathing apparatus and maintain adequate visibility, including a wide viewing angle and resolution similar to that of commercial displays. We developed the optical system testing modules and prototypes of the integrated breathing apparatus. Through iterative testing, the thickness of the output optical module in front of the eyes was reduced from 50 mm to 60 mm to less than 20 mm while maintaining a viewing angle of 103°. In addition, the resolution and image quality degradation of the light field in the display was mitigated. Hence, we obtained a display with a structure consistent with the needs of firefighters in the field. In future work, we will conduct user evaluation regarding fire scene reproducibility by combining immersive VR fire training and real firefighting equipment.

공간정보를 활용한 소방시설의 관리방안 연구 (A Study on the Management Plan of Fire Protection System Utilizing Urban Spatial Information)

  • 방창훈
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.98-104
    • /
    • 2019
  • 본 연구는 공간정보를 활용하여 소방시설의 효율적인 관리 방안을 연구하고 관련 소방산업 발전을 위한 기초자료 구축을 목적으로 한다. 소방시설 관리의 오동작과 관리부실 등의 문제점을 극복하는 방안으로 공간정보를 소방시설 분야에 도입하고자 관련 법규와 소방시설의 공간정보 구축방안을 논의하였다. 소방시설의 효율적인 관리를 위하여 공간정보 기술을 포함하는 소방시설 관련 법률의 개정과 소방시설 공간정보의 표준화와 유효성, 일관성을 유지하는 것이 필요하다.

산불예방 및 진압대책의 통합관리체계 구축 방안 연구 (A Study on the Establishment of an Integrated Management System for Forest Fire Prevention and Suppression Measures)

  • 이정일
    • 대한안전경영과학회지
    • /
    • 제24권2호
    • /
    • pp.163-169
    • /
    • 2022
  • Recently, in Korea, if a very large forest fire occurs due to the people's carelessness, it is of great interest because it spreads into a large forest fire. If a wildfire spreads and becomes large, it will inflict great damage (appointment and property), and the damage is irreversible. The best way to extinguish a wildfire is to prevent it before it occurs. If a forest fire occurs due to a failure in prevention, the early firefighting activities to prevent the progress of the forest fire by promptly dispatching it by reporting it and approaching the site as soon as possible should now be managed with a systematic integrated management system. To do so, it is necessary to prepare a preventive system, such as issuing warnings for each weather condition by the Korea Forest Service, consisting of cooperation (support) activities for forest fire prevention by related organizations, etc. In order to minimize the loss of precious lives and forests, measures have been taken to establish a system, to establish a prompt and accurate situation reporting system, and to establish an integrated command system (ICS) for on-site commanders.

소방활동방해죄의 의미와 구성요건 개선에 관한 검토 -119구급활동 방해를 중심으로- (A Review on the Improvement of the Meaning and Composition Requirements of Interference with Fire Protection Activities - Focusing on Interference with 119 EMS Activities -)

  • 홍영표
    • 의료법학
    • /
    • 제24권3호
    • /
    • pp.105-124
    • /
    • 2023
  • 현대 사회는 뜻밖의 사고와 위험 상황으로 불안정한 환경에 직면하고 있다. 예를 들어 분당 다리 붕괴사고와 이태원 압사사고 등이 그 예가 될 것이다. 이와 함께 급성심정지나 뇌졸중과 같은 중대한 응급상황이 발생하였을 때, 신속한 조치와 전문 의료 기관으로의 원활한 이송이 필요한 경우 또한 빈번하게 발생하고 있다. 이러한 위험 요소에 대응하기 위해 국가는 국민의 생명과 안전을 보호하기 위한 다양한 시스템을 구축하고 있는데, 119구급대는 응급 의료 시스템 중 핵심적인 역할을 수행한다. 중대한 외상 환자나 중증 질환 환자의 응급 상황에 즉각적으로 대응하여 손상을 최소화하고, 응급의료 기관으로 신속하게 이송하여 전문적인 치료를 제공함으로써 환자의 생명과 안전을 보호하는 것이 그 목표이다. 이와 관련된 핵심 활동이 구급활동인 것이다. 특히, 119구급시스템은 응급 환자의 병원 이송을 책임지는 핵심 기관이나, 구급대원들은 업무수행 중 구급활동 방해 사례에 여전히 직면하고 있다. 이러한 방해 사례는 경찰의 협조 노력에도 불구하고 줄어들지 않고 있고, 구급활동은 공무집행 방해죄와 유사한 특성을 지니며, 응급의료 시스템 내에서 근무하는 응급의료 종사자에 대한 폭행 및 장비 파손과 같은 사례와도 유사한 형태를 보인다. 따라서 119구급시스템을 포함한 응급 의료 활동을 수행하는 과정에서 발생하는 방해 문제에 대한 심층적인 이해와 개선 노력이 필요하다. 이러한 문제에 대한 해결책은 "소방기본법"과 "119구조·구급에 관한 법률"을 중심으로 구급활동 방해죄의 조건을 정립하고 개선하는 것이다.

3D 모델링 기반 빌딩관제시스템의 설계 및 구현 (Design and Implementation of Building Control System based 3D Modeling)

  • 문상호;김병목;이계은
    • 한국멀티미디어학회논문지
    • /
    • 제23권5호
    • /
    • pp.673-682
    • /
    • 2020
  • Buildings are becoming more and more high-rise and large-scale in recent years, so in the event of a disaster such as a fire, enormous human and economic damage is expected. Therefore, management, security, and fire control are essential for large buildings in the city. Because these large buildings are very complex outside and inside, they need a three-dimensional control based on 3D modeling rather than a simple flat-oriented control. To do this, this paper designed and implemented a building control system based on 3D modeling. Specifically, we designed a 3D building / facility editing module for 3D modeling of buildings, a 3D based control module for building control, and a linkage module that connects information such as firefighting equipment, electrical equipment and IoT equipment. Based on this design, a building control system based on 3D modeling was implemented.