• 제목/요약/키워드: Fire-through

Search Result 2,292, Processing Time 0.036 seconds

Normalized Difference Vegetation Index based on Landsat Images Variations between Artificial and Natural Restoration Areas after Forest Fire (산불 지역 인공·자연복원에 따른 Landsat영상 기반 식생지수 비교)

  • Noh, Jiseon;Choi, Jaeyong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.5
    • /
    • pp.43-57
    • /
    • 2022
  • This study aims to classify forest fire-affected areas, identify forest types by the intensity of forest fire damage using multi-time Landsat-satellite images before and after forest fires and to analyze the effects of artificial restoration sites and natural restoration sites. The difference in the values of the Normalized Burned Ratio(NBR) before and after forest fire damage not only maximized the identification of forest fire affected and unaffected areas, but also quantified the intensity of forest fire damage. The index was also used to confirm that the higher the intensity of forest fire damage in all forest fire-affected areas, the higher the proportion of coniferous forests, relatively. Monitoring was conducted after forest fires through Normalized Difference Vegetation Index(NDVI), an index suitable for the analysis of effects by restoration type and the NDVI values for artificial restoration sites were found to no longer be higher after recovering the average NDVI prior to the forest fire. On the other hand, the natural restoration site witnessed that the average NDVI value gradually became higher than before the forest fires. The study result confirms the natural resilience of forests and these results can serve as a basis for decision-making for future restoration plans for the forest fire affected areas. Further analysis with various conditions is required to improve accuracy and utilization for the policies, in particular, spatial analysis through forest maps as well as review through site checks before and immediately after forest fires. More precise analysis on the effects of restoration will be available based on a long term monitoring.

A Reliability Analysis on FDS Pyrolysis Model through Comparing the Room-Corner (ISO 9705) Test (룸 코너 콘 칼로리미터 시험(ISO 9705)과 비교를 통한 FDS 열분해 모델의 신뢰성 분석)

  • Yang, Sung-Jin;Lee, Chang-Deok;Oh, Ji-Eun;Kang, Chan-Yong;Kim, Hag-Beom;Lee, Duck-Hee
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.585-593
    • /
    • 2011
  • Actual fire test under a laboratory and fire simulation by using computer are considered into main methodology in order to estimate and predict fire size of railway train. Even if practical fire size could be obtained from the full-model railway car test such as a large scale cone-calorimeter test, it is not always possible and realistic due to that expensive cost and attendant dangers could in no way be negligible. In this point of view, fire simulation analysis method based on the computational fluid dynamics could be proposed as an alternative and it seems to be also efficient and reasonable. However, simulation results have to be verified and validated in accordance with the proper procedure including comparing analysis with the actual fire test. In this paper, fire load and growth aspect was investigated through the room corner test (ISO 9705) for the mock-up model of the actual railway car. Then, it was compared with the output data derived from the simulation by using Pyrolysis Model of the FDS (Fire Dynamics Simulator, by NIST) for the exact same domain and condition corresponding with pre-performed room-corner test. This preliminary verified and validated fire modeling method could enhance the reliability of output data derived from the fire simulation under the similar domain and condition.

  • PDF

A Study on the Basic Ideas for Fire Fighting Prevention System in Traditional Folk Village - Focused on Oeam Folk Village in Asan - (전통민속마을 소방방재 기본구상 - 아산 외암민속마을을 중심으로 -)

  • Lee, Jeong-Soo;Lee, Wang-Kee;Oh, Kyu-Hyung;Shin, Kyo-Young;Kwon, Heung-Soon
    • Journal of architectural history
    • /
    • v.19 no.1
    • /
    • pp.71-90
    • /
    • 2010
  • This research has set up the fire protection and early suppression plan for Asan Oeam folk village which is composed of traditional wooden building instinct or complex. The results of this study are as follows. 1. The traditional wooden buildings require attentive considerations about the fire property of the Waga and the straw roofed house. Especially, as the straw roofed house has property that the transfer and development of the fire is fast. Therefore we studied on the transferring possibilities of the fire dangerous instinct through measuring the distance from of the eaves edge and trees in neighboring house. 2. This research proposes the tools for the priority protective building through consideration of fire risk and cultural priority because the fire prevention for all is impossible at the same time. 3. The most important thing is preserve the cultural identities of traditional folk village in establishing the fire hydrant and fire prevention facilities. Traditional folk village landscape should be considered.

Fire Risk Assessment Based on Weather Information Using Data Mining (데이터마이닝을 이용한 기상정보에 따른 화재 위험 평가)

  • Ryu, Joung Woo;Kwon, Seong-Pil
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.88-95
    • /
    • 2015
  • We propose a weather-related service for fire risk assessment in order to increase fire safety awareness in everyday life. The proposed service offers a fire risk assessment level according to weather forecasts and a degree of fire risk according to fire factors under certain weather conditions. In order to estimate the fire risk, we produced a risk matrix through data mining with a decision tree using investigation data and weather data. Through the proposed service, residents can calculate the degree of fire risk under certain weather conditions using the fire factors around them. In addition, they can choose from various solutions to reduce fire risk. In order to demonstrate the feasibility of the proposed services, we developed a system that offers the services. Whenever weather forecasting is carried out by the Korea Meteorological Administration, the system produces the fire risk assessment levels for seven major cities and nine provinces of South Korea in an online process, as well as the fire risk according to fire factors for the weather conditions in each region.

A Study on Powder Fire Extinguisher Design with RULA Technique Used (RULA 평가기법을 활용한 분말소화기 디자인 연구)

  • Kang, Chaewoo;Kim, Dueknam
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.117-123
    • /
    • 2017
  • This study was intended to find methods of fire extinguishing system designs that can improve the equipment's usability. In this study, the fire suppression experiment through fire extinguishers and the data drawn through the experiment were analyzed, and then the guideline for the improvement of designs was presented. The procedure is as follows. A fire suppression experiment with the use of fire extinguishers was done by 43 average adults. The whole process of the fire suppression was videotaped, and then captured major scenes were analyzed with the use of RULA, a human engineering measurement tool. The analyzed data were divided into 4 steps, and then the guideline for design improvement was presented. The summary of the study is as follows. Step 1, Fire extinguisher distance step. To reduce overload occurring at the process of holding fire extinguishers suddenly, wheels are attached to the body of extinguishers, or pedestals are installed. Step 2, Fire extinguisher transportation step. The length of hose is extended, or fire fighting water is sprayed far, so that overload of legs occurring at the process of travel can be reduced. In addition, the weight of fire extinguisher shouldn't be over 2 kg. Step 3, Safety pin removal stage. Safety pins should be applied with button type, so that excessive posture of lower limbs and excessive twisting of wrists won't happen during safety pin removal process. Besides, safety pins should be designed for easy identification and operation. Step 4, Fire extinguishing agent spraying step. To reduce overload occurring at sudden spraying of fire fighting water, pressure should be increased gradually until high pressure. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.

A Study on the Development of AI-Based Fire Fighting Facility Design Technology through Image Recognition (이미지 인식을 통한 AI 기반 소방 시설 설계 기술 개발에 관한 연구)

  • Gi-Tae Nam;Seo-Ki Jun;Doo-Chan Choi
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.883-890
    • /
    • 2022
  • Purpose: Currently, in the case of domestic fire fighting facility design, it is difficult to secure highquality manpower due to low design costs and overheated competition between companies, so there is a limit to improving the fire safety performance of buildings. Accordingly, AI-based firefighting design solutions were studied to solve these problems and secure leading fire engineering technologies. Method: Through AutoCAD, which is widely used in existing fire fighting design, the procedures required for basic design and implementation design were processed, and AI technology was utilized through the YOLO v4 object recognition deep learning model. Result: Through the design process for fire fighting facilities, the facility was determined and the drawing design automation was carried out. In addition, by learning images of doors and pillars, artificial intelligence recognized the part and implemented the function of selecting boundary areas and installing piping and fire fighting facilities. Conclusion: Based on artificial intelligence technology, it was confirmed that human and material resources could be reduced when creating basic and implementation design drawings for building fire protection facilities, and technology was secured in artificial intelligence-based fire fighting design through prior technology development.

Investigation of Performent Standards for the Fire Damper (방화Damper의 성능기준 고찰)

  • Jo, Jung-Dal
    • Fire Protection Technology
    • /
    • s.12
    • /
    • pp.10-17
    • /
    • 1992
  • Dampers which being installad in air duct are Valume damper, fire damper, leakage rated damper, but among them fire damper and leakage rated damper are used for preventing the spread of flame, hot gas and smoke through the duct. this report is aimed to intorduce the test example of the multiple fire damper which was conducted F.I.L.K, simuetaneously to investigate the performent standards and Structure of the fire damper which settled in several countries.

  • PDF

Feasibility Study on the Fire Scenario Design of a Couch Burning through a Fire Spread Model (화염 전파모델을 이용한 소파화재 설계화원구성의 적용성 연구)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.37-42
    • /
    • 2016
  • The present study has been performed to examine the feasibility of a flame spread model on the design fire scenario for fire risk analysis. Thermo-Gravimetric analysis and sample burning test were conducted to obtain the material properties of a single couch covered with synthetic leather material and a series of FDS calculations applying with the measured material properties were performed for different grid sizes. The overall fire growth characteristics predicted by the fire model were quite different from the results of a real scale fire test and the initial peak value of the HRR and total released energy showed the results within a 30% discrepancy for the computational grids used in the present study. The current model has some limitations in predicting the fire growth characteristics, such as fire growth rate and the time to the maximum HRR. This study shows that the fire model may be applicable to creating the design fire scenario through continuous model improvement and detailed material properties.

A Study on Enhancing Professionalism of Fire Examination by Bringing the Legal Investigation Right on Fire to Fire Department (소방조직의 화재수사권 확보를 통한 화재조사 전문성 향상에 관한 연구)

  • Kim, Seong-Gon;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.111-120
    • /
    • 2014
  • This study focused on the review of the korean fire investigation system and will provide the means for having the legal investigation right. The most important thing is to give fire department a perfect legal investigation right on fire including police areas(seeking and examining the case at first stage). And it should be stated in criminal law. With the joint effort between Fire department and Police department, we can develop the reformation, enlightening programs for the arsons or fire related criminals. Through this, it systematically have to be good for fire prevention and can be helpful to enhancing professionalism of fire examination.