• Title/Summary/Keyword: Fire-through

Search Result 2,292, Processing Time 0.032 seconds

A Development of Assessment Model for Maintenance of Type R Fire Alarm System in the Building

  • Lee, Su-Kyung;Yoo, Sang-Bin;Nam, Yang-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.633-640
    • /
    • 1997
  • Type R fire alarm is required intelligent buildings and height buildings which was based on automatic system. But in Korea, maintenance of fire alarm system is very poor. In this study, we developed assessment model for the type R fire alarm system which was assessed by using 96 checklist items. The assessment model was tested through the actual 4 buildings with type R fire alarm system. It is shown that present model can be applied for the assessment of all buildings through the examination of the suitability of assessment model by actual assessment. Also, it was made easily fire manager to carry out checklist for type R fire alarm system in buildings.

  • PDF

Fire Risk Analysis through Airfryer's Fire Cases and Reproduction Experiments (에어프라이어의 화재사례와 재현실험을 통한 화재위험성 분석)

  • Lee, Jung-Il;Jo, Myeng-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.39-46
    • /
    • 2020
  • This paper recognizes the risk of ignition of air fryer (machine that can cook fried dishes with hot air without oil) that is far exceeding the sales rate of microwave ovens, which is necessary to modern household kitchen, and identifies fire risk through the operation principle of the process of heat transfer, and the main structure of the machine. The fire test that we conducted is to observe the risk of ignition of the machine due to the damage to the safety system and the possibility of igniting oil paper along with food, to experiment with the possibility of ignition due to blockage of the exhaust due to obstacles, and accumulation of oil stains on the hot wire, and to present the method of fire control and devise countermeasures.

A Study on Platform Development of Fire Detector applying IoT (화재감지기에 사물인터넷을 적용한 플랫폼 개발에 관한 연구)

  • Lee, Hae-Keon;Kwak, Dong-Kurl;Lee, Bong-Seob;Jung, Do-Young
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.1-3
    • /
    • 2018
  • When a fire is detected by a sensor of a fire detector, the fire is notified to the manager through the siren. However, if the manager is not indoors, prompt action may not be taken in the event of a fire. In this study, we would like to propose a platform system for fire prevention applying IoT to prevent problems that arise when building manager is absent. This paper presents the structure and operation principle of fire prevention platform system design using IoT, describes the overall system design through fire detector H/W design, micom S/W design and Android application development, and is expected to develop a system that can respond a little faster in case of fire.

  • PDF

Developing of Forest Fire Occurrence Probability Model by Using the Meteorological Characteristics in Korea (기상특성을 이용한 전국 산불발생확률모형 개발)

  • Lee Si Young;Han Sang Yoel;Won Myoung Soo;An Sang Hyun;Lee Myung Bo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.4
    • /
    • pp.242-249
    • /
    • 2004
  • This study was conducted to develop a forest fire occurrence model using meteorological characteristics for the practical purpose of forecasting forest fire danger. Forest fire in South Korea is highly influenced by humidity, wind speed, and temperature. To effectively forecast forest fire occurrence, we need to develop a forest fire danger rating model using weather factors associated with forest fire. Forest fore occurrence patterns were investigated statistically to develop a forest fire danger rating index using time series weather data sets collected from 8 meteorological observation centers. The data sets were for 5 years from 1997 through 2001. Development of the forest fire occurrence probability model used a logistic regression function with forest fire occurrence data and meteorological variables. An eight-province probability model by was developed. The meteorological variables that emerged as affective to forest fire occurrence are effective humidity, wind speed, and temperature. A forest fire occurrence danger rating index of through 10 was developed as a function of daily weather index (DWI).

Designing method for fire safety of steel box bridge girders

  • Li, Xuyang;Zhang, Gang;Kodur, Venkatesh;He, Shuanhai;Huang, Qiao
    • Steel and Composite Structures
    • /
    • v.38 no.6
    • /
    • pp.657-670
    • /
    • 2021
  • This paper presents a designing method for enhancing fire resistance of steel box bridge girders (closed steel box bridge girder supporting a thin concrete slab) through taking into account such parameters namely; fire severity, type of longitudinal stiffeners (I, L, and T shaped), and number of longitudinal stiffeners. A validated 3-D finite element model, developed through the computer program ANSYS, is utilized to go over the fire response of a typical steel box bridge girder using the transient thermo-structural analysis method. Results from the numerical analysis show that fire severity and type of longitudinal stiffeners welded on bottom flange have significant influence on fire resistance of steel box bridge girders. T shaped longitudinal stiffeners applied on bottom flange can highly prevent collapse of steel box bridge girders towards the end of fire exposure. Increase of longitudinal stiffeners on bottom flange and web can slightly enhance fire resistance of steel box bridge girders. Rate of deflection-based criterion can be reliable to evaluate fire resistance of steel box bridge girders in most fire exposure cases. Thus, T shaped longitudinal stiffeners on bottom flange incorporated into bridge fire-resistance design can significantly enhance fire resistance of steel box bridge girders.

Preventive Priority Methods Based on the Analysis of Fire Accident Causes in Construction Site (건설현장 화재 발생 요인 분석에 따른 예방우선순위 연구)

  • Kim, Hee-su;Jang, Sang-chul;Joo, Jin-gyu
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.2 no.2
    • /
    • pp.50-55
    • /
    • 2019
  • Currently, safety management is becoming important at domestic construction sites. Despite the importance of safety management, accidents at construction sites are steadily increasing. Fire accidents among safety accidents cause not only negative effects on schedule delay or work plans at construction sites, but also huge casualties. Therefore, the purpose of this research is to extract the causes of fire at the construction site through the case of fire at the construction site, and to prioritize prevention through the analysis of the factors to contribute to the prevention of fire. As a research method, we select fire factors through case, conduct surveys through expert group, and analyze survey through AHP technique. The results of the AHP analysis of the survey of expert groups showed that the workers and their sub-item ranked high. Therefore, the priority for fire prevention was given, and this research is believed to help prevent fire.

Verification of firefighters' heuristics through big data analysis (빅데이터 분석을 통한 소방관의 경험법칙 검증 및 화재예방 활용)

  • Park, Sohyun;Park, Jeong-Hoon;Shin, Eun-Ji;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.50-55
    • /
    • 2020
  • The heuristics accumulated in the field activities of firefighters were reviewed through big data analysis of fire occurrences in Gyeonggi-do and researched to be utilized for proper fire prevention activities according to time, day, and target through quantitative modeling. Empirical rules with high sympathy were collected through direct interviews with firefighters. Among them, the rule of thumb that "Friday is the most fire-prone" is considered to be the most important in terms of fire monitoring and prediction. A big data comparison analysis was conducted, including the number of fires and damages that occurred in Gyeonggi-do in 2018. Furthermore, fire occurrence patterns by region, day of the week, time of day, and building type were derived. Regarding empirical rules that have been validated through research, relatively inexperienced firefighters also can make decisions by relying on refined quantitative predictive modeling and empirical rules including local government and time-based factors that reflect big fire occurrence data.

조사연구-공기흡입 화재탐지설비(ADS)에 대한 고찰

  • Ryu, Eun-Yeol
    • Fire Protection Technology
    • /
    • s.19
    • /
    • pp.17-21
    • /
    • 1995
  • This is to study installation standards of aspirating devices and detectors, which are components of ADS(aspirating fire detection system). The BFPSA(British Fire Protection System Association) code was mainly referred is studying. ADS aspirated air and smoke through the pipe and then checks if there is fire or not. It is now in the limelight because it can early alarm in case of fire and prevent false-alarming.

  • PDF

A Study on the Fire Safety Measures of Korean Nuclear Power Plants (국내 원자력발전소 화재안전 대책에 관한 연구)

  • 김학중;손봉세;허만성
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2003.04a
    • /
    • pp.259-264
    • /
    • 2003
  • The fire protection system of Nuclear Power Plants(NPPs) is an integrated system that is applied multi-field technology. So, it needs synthetic design and analysis, that is, the plan of fire protection, fire compartment, fire detection, fire suppression, and success of safety shut down, etc. In case of a fire in NPPs, secure the safety of reactor and minimize the radioactivity contamination. For this purpose, perform the fire risk analysis and make up the deducted problem through the improvement of design or the change of operation process.

  • PDF

A Study on Developing the Educational Program for the Emergency Response against Fire Accidents in KTX (고속철도 화재사고 비상대응 교육프로그램 개발에 관한 연구)

  • Kim, Si-Gon;Park, Min-Kyu
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.41-49
    • /
    • 2009
  • In January, 2005, the "Railroad Safety Act" was presented, preparing the systematic equipment that allows several railroad operators to consider the railroad safety issue, and each of the railroad operative institutions accepted such situation that the construction of the emergent system of coping, resulting in the construction of the emergent system of coping with the railroad fire accident through the relevant study to improve the railroad security efficiency against fire. This study tried to present the on developing the emergent educational program for coping with the KTX fire accident, which is distributed to the spot, to the railroad emergency staff for improving the railroad security efficiency against fire through the education of systematic and efficient emergent countermeasure procedures against fire accidents the fire accident in KTX.