• Title/Summary/Keyword: Fire-Diagnosis

Search Result 175, Processing Time 0.03 seconds

Development of Fire-Diagnosis Concrete using Composite Sensors (복합센서를 이용한 화재자현 콘크리트의 개발)

  • Choi, Young-Wha;Kim, Ie-Sung;Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.4
    • /
    • pp.85-92
    • /
    • 2010
  • Use of concrete has undoubtedly become widespread in construction and civil engineering. Sensors are used to add functional characteristics to concrete. Self-diagnosis concrete is also being developed. The thermal protector used in the study is a sensor using the linear expansion and cubical expansion of metal. The LED(Light Emitting Diode) is a phototransistor type, and to secure high-sensitivity light, the prices of these sensors are low. Rising temperatures of concrete elements can be predicted from LED of the external virtual beam due to operation of thermal protector sensors of concrete beam caused by fire load on the concrete specimen. In this study, the development of fire-diagnosis concrete using composite sensors are the fundamental study for damage detection using simply measurements.

  • PDF

Analysis for the Thermal Properties of the Electrical Wire according to Overload and Disconnection (과부하 및 물리적 손상(반단선)에 의한 전선의 열적특성 해석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.26-31
    • /
    • 2007
  • According to the statistical analysis on the electrical fire of 2005 years, most of electrical fire is generated from short circuit(4,985 cases), overcurrent(755 cases) leakage current(391 cases), poor contact(378 cases), disconnection(36 cases) on the electrical wiring device. The researches for the fire hazard about normal electric wiring have already been progressing in the advanced country such as USA and Japan, but Comparative study of the disconnection has not been conducted. Therefore, in this paper, we have simulated the thermal analysis for electrical wire according to deteriorating time in a normal state and disconnection with electrical wire using the electrical-thermal finite element method(Flux 3D). This paper acquire basis data of electricity fire signal by disconnection and wish to help for electrical fire cause diagnosis business.

An Experimental Study on the Engineering Properties of Deteriorated Concrete by Fire Damage According to Curing Conditions (화재피해를 입은 콘크리트의 폭력에 대한 양생조건의 영향성 검토에 관한 연구)

  • Na, Chul-Sung;Kim, Young-Sun;Kim, Jae-Hwan;Kwon, Yung-Jin;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.557-560
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, this study is willing to propose fundamental data for accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the curing conditions.

  • PDF

An Experimental Study on the Engineering Properties of Deteriorated Concrete by Fire Damage According to Design Compressive Strength (화재피해를 입은 콘크리트의 폭렬에 대한 설계기준강도의 영향성 검토에 관한 연구)

  • Na, Chul-Sung;Cho, Bong-Suk;Kim, Jae-Hwan;Kwon, Yung-Jin;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.465-468
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, this study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design compressive strength.

  • PDF

The Study about the Changes of the Fire and Heat Related Symptoms and Signs On the Acute Cerebral Infarction Patients. (급성기 뇌경색 환자에서 화열 관련 증상과 증후의 변화에 관한 연구)

  • Kwak, Seung-hyuk;Park, Su-kyung;Woo, Su-kyung;Lee, Eun-chan;Park, Joo-young;Jung, Woo-sang;Moon, Sang-kwan;Cho, Ki-ho;Cho, Seung-yeon;Park, Sung-wook;Ko, Chang-nam
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.24-31
    • /
    • 2011
  • Objective : Fire and heat related symptoms and signs are considered common in acute stage of diseases. The purpose of this study is to evaluate the occurrences and changes of fire and heat related symptoms and signs in acute cerebral infarction patients. Method & subjects : 40 acute cerebral infarction patients hospitalized in Oriental medicine hospital, Kyung-Hee University, who had examined and diagnosed 2 or 3 times based on oriental medical diagnosis were selected. We chose 23 as fire and heat related symptoms and signs from 94 diagnostic articles, and we added all those scores together of each patient. We analysed the scores of fire and heat related symptoms and signs as the time passed, and depending on oriental medical diagnosis. Result : In acute cerebral infarction patients of this study, 4 of fire and heat related symptoms and signs were took 1st, 2nd, 4th and 8th places in most changeable 10 articles of total 94 articles. The mean score of fire and heat related symptoms and signs of all patients were decreased significantly over the 3 times of measurements. The 8 patients diagnosed as fire and heat diagnosis at visit1 were samely diagnosed as fire and heat diagnosis at visit2, and at visit3 5 patients of them except for 3 patients excluded between visit2 and visit3, were still diagnosed as fire and heat diagnosis. At all of 3 measuring times, the scores of fire and heat related symptoms and signs of fire and heat diagnosis group were higher than non-fire and heat diagnosis group. Conclusion : This study indicated that fire and heat related symptoms and signs were very changeable phenomenon in acute cerebral infarction patients. And they decreased as time goes on.

  • PDF

A Study on the Improvement of Repair and Reinforcement Quantity Take-off in Fire-damaged Area Using 3D Laser Scanning (3D Laser Scanning을 활용한 화재 손상 부위의 보수·보강 물량 산출 방식 개선에 관한 연구)

  • Jeong, Hoi-Jae;Ham, Nam-Hyuk;Lee, Byoung-Do;Park, Kwang-Min;Kim, Jae-Jun
    • Journal of KIBIM
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 2019
  • Recently, there is an increase in fire incidents in building structures. Due to this, the importance of fire-damaged buildings' safety diagnosis and evaluation after fire is growing. However, the existing fire-damaged safety diagnosis and evaluation methods are personnel-oriented, so the diagnostic results are intervened by investigators' subjectivity and unquantified. Thus, improper repair and reinforcement can result in secondary damage accidents and economic losses. In order to overcome these limitations, this study proposes using 3D laser scanning technology. The case analysis of fire-damaged building structures was conducted to verify the effectiveness of accuracy and manpowering by comparing the existing method and the proposed method. The proposed method using 3D laser scanning technology to obtain point cloud data of fire-damaged field. The point cloud data and BIM model is combined to inspect the fire-damaged area and depth. From inspection, quantified repair and reinforcement quantity take-off can be acquired. Also, the proposed method saves half of the manpowering within same time period compared to the existing method. Therefore, it seems that using 3D laser scanning technology in fire-damaged safety diagnosis and evaluation will improve in accuracy and saving time and manpowering.

An Experimental Study on the Engineering Properties of Deteriorated Concrete using Recycled Fine Aggregate by Fire Damage (재생잔골재를 활용한 화재피해를 입은 콘크리트의 공학적 특성에 관한 실험적 연구)

  • Kwon, Yung-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.190-196
    • /
    • 2006
  • In the existed study, a fire outbreak in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the Properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. Therefore, This study is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with making variable concrete test specimen, exposing high temperature environment, observing the explosive spalling and examining engineering property.

Development of Hardware and Monitoring Software for Stable Operation of Fire Pumps (소방펌프의 안정적 운영을 위한 하드웨어 및 모니터링 소프트웨어 개발)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.28-35
    • /
    • 2022
  • This study is aimed to develop a safety diagnosis system for fire pumps that detects normal and abnormal signals for the stable operation of the system. Hence, the following activities were carried out: first, a threshold value was identified for the normal operation and six abnormal operations (adherence of impeller, absence of water source, separation of pump and motor, run-stop operation, air inflow into the casing, and reverse-phase loss of the power line) reflecting changes in the current, flow and pressure of fire pumps; secondly, based on the identified signals, an algorithm capable of detecting three abnormal signals was developed and in terms of hardware, a current, pressure and flow sensor suitable for the analogue input values of NI-6009 was designed and installed. This combination of the hardware and software is applicable as a diagnosis system to ensure the stable operation of fire pumps.

Diagnosis for damage of fire hydrant with long valve stem in power plant. (발전소내 긴 밸브 stem을 갖는 옥외 소화전의 파손 현상 규명)

  • Sohn, Seok-Man;Lee, Sang-Guk;Lee, Wook-Ryun;Lee, Jun-Shin;Kim, Ki-Tae
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3512-3517
    • /
    • 2007
  • Nuclear power plant has many external fire hydrants that have to operate in the state of emergency such as facility fire, forest fire. The valve stem of one among them was broken 3 times for 4 years. It had long valve stem and operated under high water pressure. The elongation and the tensile strength for the broken valve stem was measured to examine the defect of material property. And the vibration level and the natural frequencies was detected to check the resonance. As the result of a diagnosis, the cause of this fault is proven buckling of long valve stem.

  • PDF

The Standardized Methods for Improvement of Maintenance Deterioration caused by Fire damage (국제 표준화를 위한 화재이후의 유지관리 시스템 개발)

  • Kwon, Young-Jin;Koo, In-Hyuk;Kim, Dong-Eun;Seo, Dong-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.230-231
    • /
    • 2013
  • A fire outbreak in a reinforcement concrete structure looses the organism by different contraction and expansion of hardened cement pastes and aggregate, and causes cracks by thermal stress, leading to the deterioration of the durability. So, concrete reinforcement structure is damaged partial or whole structure system. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary for accurate diagnosis of deterioration. In this study, consider case of investigation methods and repair work in fire damaged structure concrete.

  • PDF