• Title/Summary/Keyword: Fire spread

Search Result 473, Processing Time 0.024 seconds

A Phenomenological Study on the Flame Spread of Air Conditioner Indoor unit by Fire Tests (화재 실험을 통한 에어컨 실내기의 화염확산에 관한 현상학적 연구)

  • Choi, Seung-Bok;Lee, Seung-Hun;Choi, Min-Ki;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.89-96
    • /
    • 2013
  • The purpose of this study is to check the fire origin and cause of the fire by observing the shape of the flame propagation in air-conditioner indoor unit through the fire tests. We supposed that the flame is spread from the surroundings to the top of the air-conditioner and ignited on top of the air-conditioner with n-heptane. And then repeated this experiment twice under the same conditions. After the ignition, refrigerant filled in air-conditioner and lubricating oil exploded with large explosion and flame having high temperature and pressure belched out rapidly due to bursting refrigerant pipe linked air-conditioner between 734 seconds and 559 seconds. After result of checking the combustion residue we found that almost all of that was lost except a part of the evaporator, motor and metal. The position of short-circuit traces of wiring for the air-conditioner ignited itself is similar to that of fire damage by external flame. Therefore, we verified that it is not certain to determine the ignition cause and point by only the shape of the combustion residues.

A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes - (필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 -)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.48-54
    • /
    • 2016
  • Pilotis are support columns that lift a building above the ground. Thus, they can elevate the lowest floor to the secondfloor level and, in Korea, are used to leav a parking area below multifamily housing. However, if there is a fire in the piloti area, the cars and main entrance door are wrapped in flames. Due to the inflammability of the materials, the combustion of the cars and insulation at the ceiling of the pilotis, having a high heat release rate, can quickly destroy the front entrance of the building and spread heat, flames and a poisonous gas to the stairs and elevator pit. Therefore, the fire can quickly spread to the whole building, putting the lives of the residents in danger. This study was an in-depth accidental case study of the "Uijeongbu Fire Accident" that killed 5 residents and injured 139 others. The study identified the relationships between the fire at the piloti structure of multifamily housing and the vulnerability of this structure and its inherent weaknesses.

An experimental study of convective smoke filling (유동에 의한 연층 확산에 관한 실험적 연구)

  • 김명배;한용식
    • Fire Science and Engineering
    • /
    • v.11 no.3
    • /
    • pp.3-14
    • /
    • 1997
  • An experimental investigation of smoke spread in a corridor is made using thermocouples and visualization technique with a laser beam sheet. A speed of smoke front under a ceiling is measured by thermocouple trees. Visualization of the ceiling jet formation and of smoke filling process is carried out to observe lowering of the smoke layer. From the results, a large-scale convective motion the corridor plays dominant roles for smoke spread from visualized photos together with temperature records. A circulating motion of fluid transports some smokes to some regions where its momentum is effective. It is therefore showed that the conventional concept of lowering smoke with two-layer zone model has some restrictions for the corridor because the lowering of smoke layer has been thought to be mass transport due to relatively small scale motion such as decrease of buoyancy, mass diffusion and momentum exchange.

  • PDF

A Study on the Improvement of Performance Standard and Classification for the Firestop Accreditation System (내화충전구조 인정제도의 성능기준 및 등급분류 개선에 관한 연구)

  • Lee, H.D.;Choi, Y.J.;An, J.H.;Jeong, A.Y.;Seo, H.W.;Park, Jin O
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.32-39
    • /
    • 2020
  • The fire compartments with fire-resistant construction are installed in the principal structural parts of a building in order to reduce damage in the event of a building fire. As a fire may spread through a crack in the fire compartment, the firestop with secured performance is used according to the procedure, methods, and standards specified in the detailed operation guideline. According to the current detailed operation guideline, vertical members (wall penetration) and horizontal members (floor penetration) are classified into different categories respective to each other for the classification of the firestop. Therefore, an accreditation applicant must apply for the performance test for each structure even if the wall and the floor have the same structure. Also, Grade T is used for the firestop that penetrates the fire compartment. However, in the case of foreign countries, the use of Grade F for the firestop is allowed even if it penetrates the fire compartment. The result of the precedent studies also showed that there was a significantly low possibility of fire to spread even if Grade F was applied for a metallic duct that penetrated the fire compartment. In this study, the improved scheme for the classification and performance standard of firestops was presented by analyzing the results of precedent studies regarding the firestop and domestic and overseas firestop qualification systems.

Comparative Analysis of Forest Fire Danger Rating on the Forest Characteristics of Thinning Area and Non-thinning Area (숲 가꾸기 실행 및 미 실행지의 임분특성에 따른 산불위험성 비교분석)

  • Lee, Si-Young;Lee, Myung-Woog
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.52-58
    • /
    • 2007
  • The effect of stand-growing-stock characteristics of thinning area and non-thinning area on forest fire was studied in this work. 14 spots were selected from 3 counties such as Yangyang, Injae, and Gapyeong and on-the-spot investigations were performed to evaluate the effect of forest fire. The stand-growing-stock characteristics on the spots were analyzed through the height of tree, breast height diameter, clear length, mortality of branch, forest tree standing crop density, degree of closure, and shrub and grass cover degree. The relation between forest fire and the risk of spread of forest fire were analyzed from the analysis of the stand-growing-stock characteristics. It is considered from this work that the possibility of forest fire is decreased on the thinning area compared to the non-thinning area because of higher clearlength, lower number of tree, lower mortality of branch and higher shrub and grass cover degree.

Introduction of Fire Research in China

  • Weicheng, Fan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.35-43
    • /
    • 1997
  • Fire research is urgently needed so as to mitigate fire damage with moderate costs. A system of fire research consisting of basic research, applied research and development of new technology for fire prevention and protection is being formed in China. A general structure of organizations related to fire research is outlined. Typical research work in the State Key Lab of Fire Science is given as an example of fire research in China including: Field-Zone-Network modeling of building fire, mechanism of boilover, forest fire behavior, computer modeling of fire spread in micsogravity, and duality of fire rules and its application.

  • PDF

A Study on the Analysis of Fire Risk according to the Operation Scenario of Fire Safety Equipment (화재안전설비 작동 시나리오에 따른 화재위험분석에 관한 연구)

  • Jin, Seung-Hyeon;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.139-140
    • /
    • 2022
  • This study aims to present basic data for fire risk assessment. In the existing fire risk assessment, the operation of fire safety facilities is not considered. In addition, there is a lack of data on the fire growth rate to predict the spread of fire. Therefore, this study intends to build a fire scenario using fire statistics data. In addition, the fire growth rate is to be derived in consideration of the floor area of burnout and the cause of fire.

  • PDF

A Study on the Oxygen Index of Interior Wallpapers at Elevated Temperature (실내 내장 벽지의 고온산소지수에 대한 연구)

  • Oh, Kyu-Hyung;Lee, Sung-Eun;Kim, Hwang-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.57-62
    • /
    • 2008
  • Most of all the Korean home use a wallpaper as a decoration and finishing of interior. One of the fire spread factor in a house is a combustion of wall paper. There were some research concerning oxygen index in a ambient temperature. The purpose of this study is to investigate the difference of oxygen index of a wallpaper between ambient and high temperature and a effect on the fire spreading. Based on the result, the difference of oxygen index between ambient temperature and high temperature showed $5{\sim}8%$. Difference of 0.1% of oxygen index show big differences in combustion length of sample. Therefore, it was found that the decrease of oxygen index at elevated temperature is a important factor in fire spread.

Survey for Early Detection Techniques of Smoke and Flame using Camera Images (카메라 영상을 이용한 연기 및 화염의 조기 감지 최신 연구 동향)

  • Kang, Sung-Mo;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.4
    • /
    • pp.43-52
    • /
    • 2011
  • With the rapid development of technology, skyscrapers are widely spread and they are tightly coupled. If fire occurs in a building, it is easily spread to neighboring buildings, resulting in the large number of victims and property damages. To remove fire disasters, the need for early fire detection techniques is increasing. To detect fire, detecting devices for heat, smoke, and flame have been used widely. However, this paper surveys and presents the latest research which focuses on early smoke and flame detection algorithms and systems with camera's input images. In addition, this paper implements and evaluates the performance of these flame and smoke detection algorithms with several types of movies.

Smoke Movement by a Fire in an Enclosure (밀폐 공간내에서의 화재에 의한 연기의 유동)

  • 노재성;유홍선;김충익;윤명오
    • Fire Science and Engineering
    • /
    • v.10 no.3
    • /
    • pp.10-18
    • /
    • 1996
  • In foreign country such as USA and Japan, considerable research has been done regarding the spread of smoke in room of fire involvement by using computer. but, in our country it has not been, so, this paper presents a detailed qualitative description of phenomena which occure during typical fire scenarios through numberical analysis. The governing equations are solved by using FVM method with non-staggered grid. The SIMPLE method for pressure-velocity couple and power-law scheme for convention terms are used. It shows that a plume is formed, hot plume gases impinge on the ceiling and they spread across it. then, it eventually reaches the bounding walls of the enclosure. It takes 20s for smoke to fill the enclosure.

  • PDF