• Title/Summary/Keyword: Fire smoke

Search Result 1,099, Processing Time 0.026 seconds

Experimental Study on Ignition and Explosion Hazard by Measuring the Amount of Non-volatile (NVR) and Explosion Limit of Biodiesel Mixture (바이오디젤 혼합물의 가열잔분측정과 폭발한계 측정을 통한 발화 및 폭발위험성에 대한 실험적인 연구)

  • Kim, Ju Suk;Koh, Jae-Sun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.182-193
    • /
    • 2022
  • Purpose: By measuring and evaluating the risk of biodiesel through non-volatile residue (NVR) and flash point and explosion limit measurement at a specific temperature according to ASTM test standards, the risk of chemical fire causative substances is identified and a universal evaluation method By derivation and securing the risk-related data of the material, it can be used for the identification and analysis of the cause of the fire, and it can be applied to the risk assessment of other chemical substances Method: In order to measure the risk of biodiesel, it was measured using the non-volatile residue(NVR) measurement method, which measures how much flammable liquid is generated at a specific temperature. Heating was tested by applying KS M 5000: 2009 Test Method 4111. In addition, the flash point was measured using the method specified in ASTM E659-782005, and the energy supply method was measured using the constant temperature method. In addition, the explosion limit measurement was conducted in accordance with ASTM E 681-04 「Standard test method for concentration limits of flammability of chemicals(Vapors and gases)」 test standard. Result: As a result of checking the amount of combustible liquid by the non-volatile residue (NVR)measurement method, the non-volatile residue(NVR) of general diesel when left at 105±2℃ for 3 hours was about 30% (70% of volatile matter) and about 4% of biodiesel. In addition, similar results were obtained for the non-volatile residue(NVR)heating temperature of 150±2℃, 3 hours and 200±2℃ for 1 hour, and white smoke was generated at 200℃ or higher. In addition, similar values were obtained as a result of experimentally checking the explosion (combustion) limits of general diesel, general diesel containing 20% biodiesel, and 100% biodiesel. Therefore, it was confirmed that the flammability risk did not significantly affect the explosion risk. Conclusion: The results of this study suggested the risk judgment criteria for mixtures through experimental research on flammable mixtures for the purpose of securing the effectiveness, reliability, and reproducibility of the details of the criteria for determining dangerous substances in the existing Dangerous Materials Safety Management Act. It will be possible to provide reference data for the judgment criteria for flammable liquids that are regulated in the field. In addition, if the know-how for each test method is accumulated through this study, it is expected that it will be used as basic data in the research on risk assessment of dangerous substances and as a basis for research on the determination of dangerous substances.

Fluid Simulations in Academy Awarded Movies (아카데미상 영화에서 유체 시뮬레이션 기술)

  • Kim, Myung-Gyu;Oh, Seung-Taik;Choi, Byoung-Tae
    • Journal of the Korea Computer Graphics Society
    • /
    • v.14 no.3
    • /
    • pp.19-30
    • /
    • 2008
  • Fluid simulation for computer graphics is a field of generating the realistic movements of water, smoke, fire, explosion, sand and related phenomena to be used in motion pictures and video games. In this paper we review the fluid simulation technologies and present a trend analysis for the simulation methods used in the recent movies. First of all, for this purpose, the two methods that are most widely used for fluid simulation are explained as well as their technical issues. These two methods are classified into Eulerian grid-based and Lagrangian particle-based approaches. Next, focusing on the achievements of the scientists and engineers that the 2008 Sci-Tech Oscar Awards are given to, the features of their fluid simulation technologies are analyzed. Finally, we anticipate that there are and will be the needs for visualizing fluid interaction with rigid and soft bodies and topological change among solid, fluid and gas, creating digital creatures based on fluid simulation and presenting interaction between creature and fluid.

  • PDF

Retrieval of Aerosol Microphysical Parameter by Inversion Algorithm using Multi-wavelength Raman Lidar Data (역행렬 알고리즘을 이용한 다파장 라만 라이다 데이터의 고도별 에어로졸 Microphysical Parameter 도출)

  • Noh, Young-Min;Kim, Young-Joon;Muller, Detlef
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.1
    • /
    • pp.97-109
    • /
    • 2007
  • Vertical distribution and optical properties of atmospheric aerosols above the Korean peninsula are quite important to estimate effects of aerosol on atmospheric environment and regional radiative forcing. For the first time in Korea, vertical microphysical properties of atmospheric aerosol obtained by inversion algorithm were analyzed based on optical data of multi-wavelength Raman lidar system developed by the Advanced Environmental Monitoring Research Center (ADEMRC), Gwangju Institute Science and Technology (GIST). Data collected on 14 June 2004 at Gwangju ($35.10^{\circ}N,\;126.53^{\circ}E$) and 27 May 2005 at Anmyeon island ($36.32^{\circ}N,\;126.19^{\circ}E$) were used as raw optical data for inversion algorithm. Siberian forest fire smoke and local originated haze were observed above and within the height of PBL, respectively on 14 June 2004 according to NOAA/Hysplit backstrajectory analysis. The inversion of lidar optical data resulted in particle effective radii around $0.31{\sim}0.33{\mu}m$, single scattering albedo between $0.964{\sim}0.977$ at 532 nm in PBL and effective radii of $0.27{\mu}m$ and single scattering albedo between $0.923{\sim}0.924$ above PBL. In the case on 27 May 2005, biomass burning from east China was a main source of aerosol plume. The inversion results of the data on 27 May 2005 were found to be particle effective radii between $0.23{\sim}0.24{\mu}m$, single scattering albedo around $0.924{\sim}0.929$ at 532 nm. Additionally, the inversion values were well matched with those of Sun/sky radiometer in measurement period.

Development of Programmable and Rechargeable Moxibustion Device (전자식 구치료 시스템 개발 연구)

  • Kim, Tae-Jun;Lee, Yong-Jae;Kim, Young-In;Eom, Il-Kyu;Chae, Han;HwangBo, Min;Yang, Gi-Young;Lee, Byung-Ryul;Kim, Byoung-Chul
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.49-55
    • /
    • 2011
  • Objectives : This study was to develop programmable and rechargeable electronic moxibustion device as an interdisciplinary research focusing on traditional Korean medicine. Methods : This device deployed several advances on safety and conveniences with the advantage of programmable heat stimulation, heating material and recharging method. The gradient of heat stimulation was programmed with the reference of previous studies and own measurements. The heat curve reached its efficacious stimulus temperature after three minutes, and maintained until 13 minutes with $42^{\circ}C$. We also incorporated feedback from field hospital experiences with the help of hospital staffs. Results : This device can prevent damages from skin burn and fire accidents, and control the smoke, smell and residue of moxa itself. Conclusions : This study will contribute for the development and improvement of efficacious and safe treatment methods for the traditional Korean medicine.

The Embody of the Direction Escape Algorithm for Optimization Escape (최적 비상대피로 유도를 위한 방향성 유도 알고리즘 구현)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Dong-Woo;Mun, Hyun-Wook;Gil, Hyung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.115-120
    • /
    • 2009
  • In this parer, we design the artificial intelligent direction escape light control system to improve/complete the defects of the existing fire fighting system, and sketch an optimum escape guide algorithm for its implementation. It intends to minimize human casualties and injuries by calculating/predicting moving line of the optimum emergency escape, by means of interlocking the sensor and the reception group and analyzing the data of the combustion point and the smoke movement. The optimum escape algorithm is designed by FLOYD algorithm which calculates the shortest distance. It consists of the measuring method which calculates the shortest distance by using hazardous factors for each condition in danger which is judged by the sensor installed in each area.

Implementation of Intelligent Home Service Robot Using Wireless Internet Platform (무선인터넷 플랫폼을 이용한 지능형 홈서비스 로봇의 구현)

  • Kim, jin-hwan;Kim, dong-gyu;Son, ki-young;Shin, dong-suk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.201-205
    • /
    • 2007
  • This thesis aims to realize an intelligent home service robot that alerts the user to dangerous situations such as fires and gas leaks by utilizing wireless internet platforms in a cellular phone. The intelligent home service robot is composed of the following parts: The robot part consists of a gas sensor, a fire detector, a smoke sensor, ultrasonic sensors, motors, a camera and a Blue-tooth module and perceives various danger circumstances; The middleware part connects the robot part with the mobile part through the middleware applications, monitors the robot and notifies an emergency situation using SMS modules; The mobile part communicates with the middleware using TCP/IP protocol and controls the robot through various commands; The proposed scheme is to control the sensors of the robot part through and Atmega128 processor, and the mobile part was developed based on the WIPI platform. The robot and middleware parts will be installed in the household, and will be controled by mobile part from the outside.

  • PDF

Design of Smart Device Assistive Emergency WayFinder Using Vision Based Emergency Exit Sign Detection

  • Lee, Minwoo;Mariappan, Vinayagam;Mfitumukiza, Joseph;Lee, Junghoon;Cho, Juphil;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.101-106
    • /
    • 2017
  • In this paper, we present Emergency exit signs are installed to provide escape routes or ways in buildings like shopping malls, hospitals, industry, and government complex, etc. and various other places for safety purpose to aid people to escape easily during emergency situations. In case of an emergency situation like smoke, fire, bad lightings and crowded stamped condition at emergency situations, it's difficult for people to recognize the emergency exit signs and emergency doors to exit from the emergency building areas. This paper propose an automatic emergency exit sing recognition to find exit direction using a smart device. The proposed approach aims to develop an computer vision based smart phone application to detect emergency exit signs using the smart device camera and guide the direction to escape in the visible and audible output format. In this research, a CAMShift object tracking approach is used to detect the emergency exit sign and the direction information extracted using template matching method. The direction information of the exit sign is stored in a text format and then using text-to-speech the text synthesized to audible acoustic signal. The synthesized acoustic signal render on smart device speaker as an escape guide information to the user. This research result is analyzed and concluded from the views of visual elements selecting, EXIT appearance design and EXIT's placement in the building, which is very valuable and can be commonly referred in wayfinder system.

Real-time Intelligent Exit Path Indicator Using BLE Beacon Enabled Emergency Exit Sign Controller

  • Jung, Joonseok;Kwon, Jongman;Jung, Soonho;Lee, Minwoo;Mariappan, Vinayagam;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • Emergency lights and exit signs are an indispensable part of safety precautions for effective evacuation in case of emergency in public buildings. These emergency sign indicates safe escape routes and emergency doors, using an internationally recognizable sign. However visibility of those signs drops drastically in case of emergency situations like fire smoke, etc. and loss of visibility causes serious problems for safety evacuation. This paper propose a novel emergency light and exit sign built-in with Bluetooth Low Energy (BLE) Beacon to assist the emergency self-guiding evacuation using devices for crisis and emergency management to avoid panic condition inside the buildings. In this approach, the emergency light and exit sign with the BLE beacons deployed in the indoor environments and the smart devices detect their indoor positions, direction to move, and next exit sign position from beacon messages and interact with map server in the Internet / Intranet over the available LTE and/or Wi-Fi network connectivity. The map server generate an optimal emergency exit path according to the nearest emergency exit based on a novel graph generation method for less route computation for each smart device. All emergency exit path data interfaces among three system components, the emergency exit signs, map server, and smart devices, have been defined for modular implementation of our emergency evacuation system. The proposed exit sign experimental system has been deployed and evaluated in real-time building environment thoroughly and gives a good evidence that the modular design of the proposed exit sign system and a novel approach to compute emergency exit path route based on the BLE beacon message, map server, and smart devices is competitive and viable.

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.

Interference and Re-Inflow of Contaminated Air in Successive Tunnel (연속터널에서의 오염물질 재유입 및 환기영향평가)

  • Kim, Young-Geun;Kim, Woo-Sung;Wye, Yong-Gon;Kim, Nam-Yung;Lee, Ho-Suk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.2
    • /
    • pp.115-134
    • /
    • 2003
  • Recently, there are many cases in the roadway design for successive tunnel with small distance between two tunnels. In this case, the degree of interference for successive tunnels is a significant consideration in the design of ventilation systems. Also, Re-inflows of contaminated air in successive tunnel make serious ventilation problems in case of fire accident in the tunnel. In this study, for successive tunnels in Donghae highway project, the concentration of contaminant such as CO, NOx and Smoke were calculated by numerical analysis using 1D and 3D-CFD analysis. And, the rate of re-inflow at the portals of successive tunnel according to the direction of wind were analysed.

  • PDF