Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage (화재피해 감소 위한 자동소화장치 적용범위 개선)

  • Baek, Chang Sun;Park, In Seon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

Improvement Plan of Fire-Related Laws of Disaster Prevention Facilities of Road Tunnels (도로터널 방재시설의 소방관계법령 개선방안)

  • Seo, Hyo-Seon;Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.124-131
    • /
    • 2019
  • When a fire occurs in a road tunnel, it is likely to develop into a major disaster because of its sealed structural characteristics. Because of this, a range of disaster prevention facilities should be installed, and they should show their appropriate functions in fire prevention and response. In addition, the installation of essential disaster prevention facilities is missing due to the lack of considering an extension of continuous tunnels and soundproof tunnels. For these reasons, it was judged that an amendment to the law would be necessary. Therefore, this paper reviewed the changes in domestic laws related to the disaster prevention facilities of road tunnels, and the results of the study on the parts that need to be revised in the fire-related laws through a comparative analysis between laws are as follows. First, consecutive tunnels should consider the sum of the extensions of the individual tunnels and ensure that the soundproof tunnels are included in the category of tunnels in the law. In this way, the necessary disaster prevention facilities should be installed. Second, it is necessary to secure a legal justification for installing disaster prevention facilities in tunnels. Therefore, it is essential that water mist fire extinguishing system facilities, emergency broadcasting facilities, and leading lights, which are excluded from installation in tunnels, are specified in the Fire-related laws. Third, to specify in the law that air respirators must be provided in the tunnel is necessary from the viewpoint of the field response. Accordingly, it will make a great contribution to the fire-fighting activities and the life-saving efforts by fire-fighters.

Fire Protection Regulations for Ensuring Fire Safety during Decommissioning Nuclear Power Plants in Korea (해체원전 화재안전 확보를 위한 화재방호 규정 고찰)

  • Kim, Jung-Wun;Park, Chan-Geun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.134-140
    • /
    • 2020
  • Nuclear power plants (NPPs) in Korea are required to be maintained using a defense in-depth approach to prevent leakage of radioactive substances outside the plant and allow safe shutdown in the event of a fire. Periodic testing must be conducted to ensure that the fire protection facilities perform as required by the laws for various nuclear reactor types. In June 2017, for the first time in Korea, a nuclear plant, Kori Unit 1, was permanently shut down. It was prepared for decommissioning in accordance with the fire protection regulations imposed by the regulatory body. However, a standard protocol is necessary for systematically establishing the fire protection program for decommissioning of NPPs in the future. Therefore, the nuclear legal systems of countries with many operating nuclear power plants, such as the United States, Japan, Canada, and various European countries, were reviewed and guidelines for establishing a fire protection program for decommissioning NPPs was suggested; the fire protection requirements stated by Reg Guide 1.191 (Decommissioning fire protection program for NPPs during decommissioning and permanent shutdown) were used as a model. Suggestions for establishing legal regulations to optimize fire protection programs and secure basic technology for decommissioning NPPs were also made.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

A Study on Research Technique of the combustibles an Housing Facilities in Korea (국내 주거시설의 가연물 조사 기법에 관한 연구)

  • Shin, Yi-Chul;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.289-293
    • /
    • 2008
  • In performance-based on fire safety design of buildings, design fires are assumed to be relatively coarse information on potential combustible objects described by its name, weight, size and main constituent materials. As early as 1970s, researchers from Japan has employed various methods of research regarding combustibles investigations. In result, researchers came up with one method that is being presently used. Therefore, our country basis in collection of data for combustibles yielded average measure, receipt rate of furniture usage and execution of combustible investigations to occupancy zone of university respondents. We have found out problem about excessive usage of multi-outlet extensions through research.

  • PDF

Uniform Hazard Spectrum for Seismic Design of Fire Protection Facilities (소방시설의 내진설계를 위한 등재해도 스펙트럼)

  • Kim, Jun-Kyoung;Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.26-35
    • /
    • 2017
  • Since the Northridge earthquake (1994) and Kobe earthquake (1995), the concept of performance-based design has been actively introduced to design major structures and buildings. Recently, the seismic design code was established for fire protection facilities. Therefore, the important fire protection facilities should be designed and constructed according to the seismic design code. Accordingly, uniform hazard spectra (UHS), with annual exceedance probabilities, corresponding to the performance level, such as operational, immediate occupancy, life safety, and collapse prevention, are required for performance-based design. Using the method of probabilistic seismic hazard analysis (PSHA), the uniform hazard spectra for 5 major cities in Korea with a recurrence period of 500, 1,000, and 2,500 years corresponding to frequencies of (0.5, 1.0, 2.0, 5.0, 10.0)Hz and PGA, were analyzed. The expert panel was comprised of 10 members in seismology and tectonics. The ground motion prediction equations and several seismo tectonic models suggested by 10 expert panel members in seismology and tectonics were used as the input data for uniform hazard spectrum analysis. According to sensitivity analysis, the parameter of spectral ground motion prediction equations has a greater impact on the seismic hazard than seismotectonic models. The resulting uniform hazard spectra showed maximum values of the seismic hazard at a frequency of 10Hz and also showed the shape characteristics, which are similar to previous studies and related technical guides for nuclear facilities.

Problems and Solutions for Securing Fire Resistance Performance in Fire Protection doors (방화문 내화성능 확보에 대한 제도적 문제점 및 해결방안)

  • Kim, Juseong;Kim, Siwon;Cho, Youngduk;Kim, Jaejun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.2
    • /
    • pp.22-29
    • /
    • 2020
  • Among many fire-related laws and standards such as fire protection, fire doors are important facilities that play a role in preventing the spread of fire and smoke in the event of fire, thereby minimizing human casualties. Accordingly, the standards for performance required by applicable laws and regulations and related enforcement rules and notices have been continuously raised and the corresponding performance must be secured. However, due to the shortcomings of the relevant laws and systems, the test results of the fire doors confirmed that there was a risk of passing products. In this study, the criteria for fire-related performance were analyzed, and the performance required by other laws, in addition to simple fire protection, was identified, the criteria were organized, and the complex performance required was clearly.

A Study on Improvement of Discharge Pressure Measurement of Indoor Fire Hydrant System (옥내소화전설비의 방수압 측정 개선에 관한 연구)

  • Min, Se-Hong;Jeong, Sang-Ho
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.67-72
    • /
    • 2012
  • Indoor fire hydrant facilities and sprinkler system applied to the initial fire suppression for buildings' interior fire are pivotal roles in extinguishing the fire in the early stage. The roof shapes of recent buildings combined with distinctive local culture and design are being constructed. Distinctive roof forms, i.e. gable roof buildings are planned and built, View point planning with the roof gardens also restricts measurement of the discharge pressure on the indoor fire hydrant, It is too narrow to gauge the water discharge pressure with deploying up to 5 water hoses. To resolve these problems improvement for the efficient management of indoor fire hydrant system and the effective early stage flame extinguishment is suggested.

A Study on the Escape Measures and Fire Protection System Improvement in Discount Stores (대형할인점의 피난대책 및 소방시설 개선방안에 관한 연구)

  • 홍성우;이영재
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.20-27
    • /
    • 2002
  • This study in focused on proposing the improvement plans for refuge and fire-fighting facilities in large shopping malls that are radically spreading. The main subjects are as follows. - The refuge measure for large shopping malls - Problems of installing the refuge facilities in stores and the solutions - Problems of installing the incendiary facilities in stores and the solutions - Problems of installing the indoor fire plug in stores and the solutions As result of the study, it has turned out that escape stairs which are set up according to the standard of size in the process of design plan, have to be decided for their amount, position, specification, etc, in consideration of the number of residents. It is also required to tighten a standard of installing a sprinkler instead of lightening the fire-fighting section in stores, considering obstacles due to facilities installed and procurement of the escape path. In addition, it needs to lighten a standard of installing the indoor fire plug, which is voluntarily set up at the store section incase of installing a sprinkler to make a practical fire-fighting facility available.

A Study on the Reform of the Evacuation Planning in the Nursing home for the Elderly (노인요양시설 피난계획 제도적 개선방안 연구)

  • Kim, Yoon-Jeong;Kim, Seok-Jun;Yoon, Miong-O
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.15 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The nursing home for the elderly has a weak point for evacuation from the fire because most of all the users are suffering from a dementia or paralysis. When it comes to night shift, it is much difficult to get them evacuated due to the lack of staffs. In addition to that, the nursing home for the elderly has such a strict control system for access that does not have a utility for escape opening. That is why they need the differentiated evacuation planning. This study is to consider the point at issues on the present conditions of law, system, and evacuation plans for the nursing home for the elderly that has some difficulties because of impaired functions of residences. This study dealt with the point at facilities and operations of the emergency evacuation system. First of all, for the point at the facilities, I found that it need to be considered on the characteristics of the elderly who has any difficulties of the self evacuation. And the established regulation did not reflect the characteristics of closed area of the nursing home for the elderly. The second, for the point at the operation of the institutions, it is pointed that there seems to be a lack of ways to manage to a emergency situation and educations on the operation staff. And the last, for the point at the operation, the requirement for the managers of fire prevention facilities are similar to that of a normal building. Furthermore there is a lack of corporation with the fire station.