• Title/Summary/Keyword: Fire protection Facilities

Search Result 194, Processing Time 0.027 seconds

Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity (단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발)

  • Joo, Nam-Kyu;Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.360-366
    • /
    • 2012
  • In the power distribution panel installed in airport or industrial facilities, MCCB has been used for main switch and ELCB for branch switch to perform human body and leakage-inducing fire protection as well as overcurrent and short circuit protection. Especially for the airport panel, increase in accident protection is needed for stable power supply due to rapid modernization with fast-growing users, higer capacity and diversification of equipment, the increase of power capacity and the breaker made slim is a main issue for now because the issue for installation space is standing out by making panel with two-row arrangement connection method, etc. due to a many use of branch ELCBs. In this thesis, we designed arc extinguishing mechanism, considered movement direction change of contact in mechanism design. Also, we designed the breaker to work stably in case of miniaturization of leakage detection circuit and reverse connection. We conducted short circuit test to verify its function and developed the breaker that can be improved protection against accidental current with slim size operating leakage function when reverse connection to help solve the problem in using space that is increasing in the airport distribution panel.

Reliability Analysis on Firewater Supply Facilities based on the Probability Theory with Considering Common Cause Failures (소방수 공급설비에 대한 공통원인고장을 고려한 확률론적 신뢰도 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.76-85
    • /
    • 2003
  • In this study, we write down the definitions, their causes and the techniques of analysis as a theoretical consideration of common cause failures, and investigate the limitation and the importance of the common cause failures by applying to the analysis on the fire protection as a representative safety facility. As you can know in the reliability analysis, most impressive cause is the malfunctions of pumping operations; especially the common cause failure of two pumps is dominant. In other words, it is possible to assess system-reliability as twice as actual without CCF From these, CCF is extraordinarily important and the results are highly dependent on the CCF factor. And although it would increase with multiple installations, the reliability are not defined as linear with those multiplications. In addition, the differences in results due to the models for analysis are not significant, whereas the various sources of data produce highly different results. Therefore, we conclude that the reliabilities are dependent on the quality of the usable data much better than the variety of models. As a result, the basic and engineering device for the preventions of CCF of the multiple facilities is to design it as reliably as to design the fire-water pump. That is to say, we must assess those reliabilities using PFD whether they are appropriate to SIL (Safety Integrity Level) which is required for the reliability in SIS (Safety Instrumented System). The result of the analysis on the reliability of the fire-water supply with CCF shows that PFD is 3.80E-3, so that it cannot be said to be designed as safely as in the level of SIL5. However, without CCF, PFD is 1.82E-3 which means that they are designed as unsafely as before.

Comparisons of the Consequences Based on the Damage Area and the Financial Loss in a Petrochemical Plant (석유화학공장에서 피해지역 및 재정적 손실에 의한 사고 피해크기 비교)

  • Kim, Bong-Hoon;Lee, Hern-Chang;Choi, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.20-27
    • /
    • 2011
  • The consequence analysis (CA) is widely using in the petrochemical plant through adoption of the process safety management (PSM) system, but it has not practical problem that the CA was not reflected effects for employee count, business interruption loss, utility usage, and etc.. In this study, to establish the practical emergency response plan and to achieve risk based management, the consequence based on the damage area and the financial loss were estimated and compared through application on facilities in the petrochemical plant. If the damage area is used, the consequence category must be determined by safety area considering simultaneously damage area, fatality area and toxic area. Also, the consequences based on the financial loss is more practical method for the case of considering process properties and circumstances.

Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection (합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현)

  • Park, No-Jin;Yu, Dong-Kuen;Yu, Hong-Kuen
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

Analysis on Factors of Importance and Performance in terms of Securing Customers of Farm Restaurants - Based on the Case of Bibijeong in Wanju-Gun - (농가레스토랑 이용고객의 중요도-만족도 분석 - 완주군 비비정을 사례로 -)

  • Han, A-Reum;Han, Jin;Lee, In-Jae;Jang, Dong-Heon
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.2
    • /
    • pp.163-175
    • /
    • 2015
  • This study aimed to analyze factors of importance and performance picked by customers of Bibijeong, a farm restaurant operated by the local community of Wanju-gun. Major points include: Recognition paths mostly were word of mouth and mass media, types of visit were in the company of friends, family members or work colleagues, and purposes of visit included consumption of meal and identifying features of the restaurant. Secondly, factor analysis showed that level of facility, atmosphere/cleanness, diversity of menu, employees, ingredients and network. The Cronbach Alpha coefficient was +0.6. Thirdly, average of importance of factors was 3.861 while average performance was 3.429. IPA analysis showed that employee(communication, customer contact) in the first quadrant proved the need for fast improvement through training. Atmosphere/cleanness (interior atmosphere, table clean, kitchen cleanliness, clean dishes, interion design) and employee(proficiency, menu recognition), foodstuff(freshness, origin, safety) in the second quadrant showed that the marketing strategy of improvement as well as maintaining current status is needed, including regular training and hygiene inspection. The third quadrant contains facilities(disability, baby, fire protection) and food menu(food packing, various menu, creative menu, menu description), network(village economic links), which showed the need for gradual improvement. The forth quadrant contains network(sights's near contains. The results so far can be summed into the statement that overcoming the basic functionality of providing meals and linking the restaurant with local attractions and local economy would be need, as well as building up the image of unique farm restaurant with local features, so that Bibijeong can serve as the centerpiece of community and foundation of exchange with other areas.

A Study on the Analysis of Hazardous Risk Factors for Component in Hydrogen Station with Water Electrolysis Device (수전해 수소충전소 부품별 유해위험요인 분석)

  • Seo, Doo-Hyoun;Rhie, Kwang-Won;Kim, Tae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.33-38
    • /
    • 2019
  • In order to invigoration the hydrogen economy, production of hydrogen needed for hydrogen charging stations and hydrogen fuel cells is needed. Generally, it is reforming used to coal fuel or natural gas. Other technologies include water electrolysis using pure water. Among these water electrolysis technologies, development is mainly carried out using PEM(Polymer Electrolyte Membrane electrolysis). In this study, the company aims to identify potential harmful hazards to PEM electrolysis hydrogen stations in the development stage among hydrogen charging stations. In order to find the hazardous factors in the facilities of the electrolysis and hydrogen charging stations, we were analyzed by Failure Mode & Effect Analysis(FMEA).

Uncontrolled Landfill Maintenance Plans through the Environmental Evaluation (환경성평가를 통한 비위생 매립지 정비방안)

  • Lee, Hae-Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.59-71
    • /
    • 2008
  • In this study, we intend to present the uncontrolled landfill maintenance plans by diversely reviewing the operating conditions of landfill and environmental effects and economical issues resulted from the operation of landfill for the purpose of suggesting the optimal maintenance plans applicable to the uncontrolled landfill and unused landfill located in Korea. We perform the basic and precise surveys against three landfill sites showing the biggest problem out of 8 unsanitary landfills sites located in Y County. We compare and review the treatment plans prepared and operated by the N Landfill. The compared and reviewed results show that the local stabilization plan is more effective than the excavation and transfer treatment plan when considering the economic efficiency only. However, the excavation and transfer treatment plan is valid when considering the diverse elements. The G Landfill is operated with separated into living waste landfill section and construction waste landfill section. However, some landfill gas collection bores or holes are installed in its living waste landfill section, which has not been used for about 20 years, as a part of follow-up control. The element causing the environmental damage is considerably reduced in its living waste landfill section. However, the effort to keep the follow-up control through the local stabilization work is required. The landfill is under processing in the construction waste landfill section. However, most of buried wastes are the inorganic wastes such as waste materials and concrete, so the maintenance plan focused on the use of top land by installing the local stabilization facilities is considered as an effective plan. The landfill is under processing in the K Landfill. It seems to be difficult to maintain this landfill through the local stabilization. The excavation and transfer treatment plan to completely remove the potential environmental pollution source is considered as the valid plan.

Pool proof safety through the old apartments redesigned to ensure safety study (노후아파트 안전관리를 통한 풀 푸르프 재설계로 안전성 확보에 관한 연구)

  • Baek, Dong Seung;Lee, Jong Hyun;Park, Sung Bong
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.280-287
    • /
    • 2018
  • Purpose: The study is based on comparative review of the actual inspection of apartments and aims at proposing easy accessible and useful safety control which is enhanced from pre-existing safety apparatus. Method: On the basis of preceding research data of apartment buildings, the study presents reported problems and real condition of apartment buildings based on Housing Related Legislation and Housing Act. Results: Safety management plans and safety inspection for buildings are needed. When conducting a safety check, traceability management system for internal/exterior facilities should be available. Most important of all, 24 hour a day of self-management system for elevators, fire protection, and security cameras is necessary. Conclusion: Through the study, there should be a process of confirming problems of building security management; such as checking the management condition through apartments' resident representatives, and seeking improvement measures.

A Case Study of Risk Assessments and Safety Measures in a PCB Manufacturing Process (인쇄회로기판 제조 공정에서 위험성평가와 안전조치 적용 사례 연구)

  • Lee, Young Man;Lee, Inseok
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.120-128
    • /
    • 2022
  • Printed circuit boards (PCBs) are a basic component in the electronics industry and are widely used in nearly all electronic products, such as mobile phones, tablet computers, and digital cameras, as well as in electric equipment. PCB manufacturing involves the use of many chemicals and chemical processes and therefore has more risks than other manufacturing sectors. This study aims to identify the causes of possible accidents during PCB manufacturing through risk assessment, develop and implement safety measures, and evaluate the effectiveness of these measures. Note that the safety measures developed to mitigate the risks of a certain process were also implemented for other similar processes. The risk assessments conducted over seven years, from 2015 to 2021, at a PCB manufacturing company identified 361 hazardous processes. Between 2016 and 2019, 41-56 hazardous processes were identified per year; such processes decreased to fewer than 20 per year after 2020. Application of the risk assessment results to the improvement of the hazardous processes with the similar characteristics seems to be effective in decreasing the risks. Equipment-related factors such as lack of appropriate maintenance, low work standards, and defective protection devices were responsible for 59.8% of all possible accidents. Because PCB manufacturing involves many chemicals, skin contact with hazardous substances, electric shock, fire, and explosion were the most common types of possible accidents (81.7%). In total, 505 safety measures were implemented, including 157 related to purchase and improvement of equipment and devices for safety (31.1%), 147 related to the installation/modification of fire prevention facilities (29.1%), and 69 related to the use of standard electrical appliances (13.7%). Risk assessment conducted after implementing the safety measures showed that these measures significantly decreased risk; 247 processes (68.4%) had a risk level of 3, corresponding to "very low," and 114 processes (31.6%) showed a risk level of 4, corresponding to "low." In particular, risk assessment of 104 processes with risk scores of 12 and 10 other processes with risk score of 16 showed that the risk decreased to 4 after implementing the safety measures. Thus, implementing these measures in similar manufacturing sectors that involve chemical processes can mitigate risk.

Uniform Hazard Spectra of 5 Major Cities in Korea (국내 5개 주요 도시에 대한 등재해도 스펙트럼)

  • Kim, Jun-Kyoung;Wee, Soung-Hoon;Kyung, Jai-Bok
    • Journal of the Korean earth science society
    • /
    • v.37 no.3
    • /
    • pp.162-172
    • /
    • 2016
  • Since the Northridge earthquake in 1994 and the Kobe earthquake in 1995 occurred, the concept of performance based design has been introduced for designing various kinds of important structures and buildings. Uniform hazard spectra (UHS), with annual exceedance probabilities, corresponding to the performance level of each structure, are required for performance-based design. The probabilistic seismic hazard analysis was performed using spectral ground motion prediction equations, which were developed from both Korean Peninsula and Central and Eastern US region, and several seismotectonic models suggested by 10 expert panel members in seismology and tectonics. The uniform hazard spectra for 5 highly populated cities in Korea, with recurrence period of 500, 1,000, and 2,500 years using the seismic hazard at the frequencies of 0.5, 1.0, 2.0, 5.0, 10.0 Hz and Peak ground acceleration (PGA) were analyzed using the probabilistic seismic hazard analysis. The sensitivity analysis suggests that spectral ground motion prediction equations impact much more on seismic hazard than what seismotectonic models do. The uniform hazard spectra commonly showed a maximum hazard at the frequency of 10 Hz and also showed the similar shape characteristics to the previous study and related technical guides to nuclear facilities.