• Title/Summary/Keyword: Fire protection Facilities

Search Result 194, Processing Time 0.024 seconds

A Study on the Management and Application for Prevention Information Communication System (방재정보통신시스템 관리 운용 및 응용에 관한 연구)

  • Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.611-618
    • /
    • 2008
  • The development of information society together with information telecommunication's influence on the human society is a ripple effect and getting wider. Among those ripple effects the disaster prevention is in the public eye in the present day. On the way to the ubiquitous society the main techniques to be concerned in ubiquitous sensor networks are the field of damage of storm and flood, safety facilities, traffic safety, industrial safety, energy safety, fire fighting, specific safety of radioactivity escape incident, environmental pollution, sea pollution, mountain and forrest disaster so on. In this paper the USN technique based on the disaster prevention communication technology service and its requirement technology and application are studied.

  • PDF

Optimization of Heat exchanger Capacity to Maximize the Performance and Energy Efficiency of TEM Dehumidifiers (열전모듈 제습기의 제습 능력 및 에너지 효율 극대화를 위한 열교환기 용량 최적화)

  • Lee, Tae-Hee
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.3
    • /
    • pp.13-20
    • /
    • 2021
  • The capacity optimization of the heat exchanger of the TEM dehumidifier was performed through numerical analysis. If the ratio of the size of heat exchangers on the cold and hot surfaces of the TEM is not appropriate, the larger the size of the heat exchanger results the lower performance and efficiency. Optimizing the ratio of heat exchangers on the cold surface of TEM can improve the performance and the efficiency compared to when the ratio is 50%. The optimal proportion of cold surface heat exchangers is inversely proportional to the sum of the size of the heat exchangers on the cold and hot surfaces. When the optimum ratio of cold surface heat exchanger was applied, the larger the sum of size of the two heat exchangers results the greater the improvement of the performance and efficiency, compared to when the ratio of cold surface heat exchangers is 50%.

A Study on the Control System of Plant Growth Using IT Convergence Technology (IT 융합기술을 이용한 식물생장 제어시스템 연구)

  • Kim, Min-Soo;Jee, Seung-Wook;Kim, Min-Kyu;Cho, Young-Chang
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.959-964
    • /
    • 2018
  • In this study, a study is conducted on a monitoring system that can control the environment of plants using sensors in conjunction with the LED light system and the plant growth control system. To verify the performance of the developed plant growth system, an experiment was conducted on the characteristics of energy efficiency, data transmission rate, and light volume control. The experiment resulted in a satisfactory result by controlling more than 80% energy efficiency, 1Mb/sec wireless communication speed, and 5 levels of optical control. The proposed system can be applied to LED plant facilities and will contribute to the automation of agriculture by organizing an automated system for production efficiency and labor cost reduction for future commercialization.

Proposal of Analyis Method for PICV Characteristics Curve Using CFD in Hydronic System (밀폐형 수배관시스템에서 CFD를 활용한 복합밸브 특성곡선 해석 방법 제안)

  • Do, Gahyeon;Kim, Jinho;Park, Woopyeng;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.2
    • /
    • pp.20-29
    • /
    • 2021
  • In this study, it is proposed that an analysis method using charatersistics curve of PICV in the CFD simulation for hydronic system. From the results, the pressure drop characteristics appeared in the region of PICV at a specified flow rate. And the CFD results are in good agreement with the experimental results. Proposed analysis method is proved that the characteristics of PICV applied to the hydronic system were properly applied in the flow analysis. This result can be applied to PICV in the complex hydronic systems. Therefore, the optimal selection of PICV in hydronic system contribute the building energy saving.

A Study on the Effect of Customized Education for Small and Medium-sized Businesses Handling Hazardous Chemicals (유해화학물질 취급 중소사업장을 대상으로 한 맞춤형 교육 효과에 관한 연구)

  • Lee, Hyo-Eun;Kim, Min-Gyu;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.979-986
    • /
    • 2022
  • Chemical accidents are increasing day by day as the industry develops. To prevent such chemical accidents, Korea enacted the Chemicals Control Act. Through these laws, systematic management of chemical substances began. There are various positions in the companies. hazardous chemical supervisors, equipment and technical human, operators and employees. Chemicals-related education for each position should be provided. As a result of the survey, hazardous chemical supervisors and equipment and technical human liked the overall content of the Chemicals Control Act and the education subject on safety management standards for facilities. Conversely, the operators liked the course on how to wear personal protective equipment. The employees preferred subjects such as classification of chemical substances and prevention of chemical accidents. Currently, various modular textbooks are widely available. Rather than general education, it is necessary to select and provide customized subjects that are preferred and interested according to the position. Then it will be more effective in understanding harzardous chemical substances and in preventing chemical accidents.

Risk Assessment of 30 MeV Cyclotron Facilities (30 MeV 사이클로트론 시설 위험성 평가)

  • Jeong, Gyo-Seong;Kim, Chong-Yeal;Lee, Jin-Woo
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.39-45
    • /
    • 2017
  • A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce $^{18}F$, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fires and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a fire. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI.

A Study for Deducing the Problems and Improvements of Health Safety and Welfare Policy for Korean Firefighters by Delphi (델파이 기법을 통한 소방공무원 보건안전정책의 문제점 및 개선방안 도출)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.34-43
    • /
    • 2020
  • Purpose: In this study, we will try to find out problems and improvements of the policies in order to verify whether the plans contribute to the health and welfare of the firefighters properly. Method: By the Delphi analysis by experts. Result: There are problems such as absence of Firefighters' hospital, insufficient mental health education program in fire department, lack of on-site risk assessment system, problem on ineffectiveness of mental and physical health care business, lack of substantiality on mental and physical stability program, absence of mental health education, ensuring the confidentiality for users of mental health programs, lack of support for parent firefighters, lack of firefighters' retirement design and insufficient treatment for female firefighters. Conclusion: There are Improvements such as establishing Firefighters' hospital, improving mental health education and training CISD leaders in the fire department, preparing disaster risk assessment system, effectiveness measurement for visiting psychological counseling projects, improving the program through customer satisfaction surveys, establishment of mental health education system, ensuring confidentiality by improving personnel systems, encourage childcare leave and introduce childcare facilities at fire stations, revitalizing retirement Firefighters and policy development for female firefighters.

A study on the Improvement Method of the Report and Reward System on an Illegal Behavior of the Emergency Exit (비상구 불법행위 신고포상제도의 개선방안에 관한 연구)

  • Kim, Myeong Sik;Lee, Tae Shik;Cho, Won Cheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.49-59
    • /
    • 2012
  • The safety management of the emergency exit, by directly related to the $civil^{\circ}$Øs dead in the fire situation, have limited by which the fire station take the on-side and control-centered way of business processing, it is expect to the effects in which the citizen have to concern and to take part. From 2010 years in the back-ground, it is operated nationally the report and reward system on an illegal behavior of the emergency exit, it is happened to the unfit operating situation in the mission and direction of the system up which the exit paparazzi act with intent to receive the reward payments. The study suggests solution through analyzing the illegal emergency exit operation result of sixteen counties and the Seoul metropolitan from year 2010 to 2011. Firstly, the report destination is adjusted to the multiple use establishments and the large-scale multiple use facilities over the limit level is limited under five times the report events of the same people in the minor endorsement. And the fine incomes should be invested to the disaster prevention acting related with the exit. Secondly, for upgrade of the report accuracy, a reporter is received the possible information for the confirmation of an illegal act, has become to lead the pre-monitoring act which the reporter is can to take the safety education and to guide the information about season and vulnerable business location. Finally, considering the support way about the encounter facility, the fire officer is not happen to occur the repetitive report in the same place, is related to the volunteer service system the report acts, consider as the volunteer service time, and must support them to act as the disaster prevention volunteer.

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.

Seismic Performance and Damage Prediction of Existing Fire-protection Pipe Systems Installed in RC Frame Structures (철근콘크리트 구조물 내 부착된 수계 관망시스템의 내진거동 및 손상예측)

  • Jung, Woo-Young;Ju, Bu-Seog
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.37-43
    • /
    • 2011
  • Reliability of piping systems is essential to the safety of any important industrial facilities. During an earthquake, damage to the piping system can occur. It can also cause considerable economic losses and the loss of life following earthquakes. Traditionally, the study of the secondary system was less important than primary structure system, however it has recently been emerging as a key issue for the effective maintenance of the structural system and to help reduce nonstructural earthquake damage. The primary objectives of this study are to evaluate seismic design requirements and the seismic performance of gas and fire protection piping systems installed in reinforced concrete (RC) buildings. In order to characterize the seismic behavior of the existing piping system in an official building, 10 simulated earthquakes and 9 recorded real earthquakes were applied to ground level and the building system by the newmark average acceleration time history method. The results developed by this research can be used for the improvement of new seismic code/regulatory guidelines of secondary systems as well as the improvement of seismic retrofitting or the strengthening of the current piping system.