A study on the Means of Egress Codes for Interior Architecture in the United States - Focused on Evacuation Elements in the Interior Architectural Design - (미국의 실내건축 피난 규정에 관한 연구 - 실내건축계획에 있어 피난 요소를 중심으로 -)

  • Kim, Young-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.3
    • /
    • pp.24-32
    • /
    • 2018
  • The law reflects the situation of the times, understands the society, and shows the will of the state and the community. The Means of Egress should be maintained from design to construction, supervision, as well as use, in order to protect the lives and property of the residents as well as the safe use of the facilities. However, Interior Architects are think that evacuation and safety regulations are complex elements that change frequently and may inhibit the idea of design. The purpose of this study is to propose a design method for the use of safe facilities in the interior architectural design on the evacuation regulations affecting the actual design by the IBC(the International Building Code) and NFPA(National Fire Protection Association) LSC (Life Safety Code). The research method is to investigate and analyze the provisions related to the evacuation of interior architecture in the US and to understand the current regulations and the evacuation regulations. We suggest to design method to the details of the hallway, corridors, aisle accessway, door way, exit path, In particular, the design of furniture, tables and chairs layout that could be obstacles to evacuation situations is presented.

A Study on the Safety and Improvement of Small Theatres in Korea (소규모 공연장 안전실태 및 개선방안에 대한 연구)

  • Park, Yong Gyu;Kim, Dong Kyun;Park, Jin Kyu;Kim, Kyung Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.22-27
    • /
    • 2014
  • The market of performance arts industry such as concert, musical and opera etc is now expanding in Korea. However, the inadequate safety management in theatres often causes some accidents. The guarantee of safety in theatres is very important since the accidents in theaters can lead to many casualties and serious property damages. In particular, the small theatres which have no obligation of safety inspection by law are very vulnerable to safety mattes. This study has done the research into the improvement of safety in small theaters through the inspection and analysis of their safety status. For the purpose, this study has inspected and analyzed the safety status of small theaters over 120 in the field of theater management and operation, fire protection, electrical facilities, ceiling structure and etc. Moreover, this study had investigated the law and technical standards related to theatre safety. This study shows that the essentials to make sure of the safety in small theaters are (1) the education to improve the sense of security of people who work in theaters (2) the training to strengthen the operating skills of the facilities in theaters (3) the cooperation and support of the related organization such as technical research center, central and local government.

A Study on the Planning Direction for Social Communication in a High-density Residential Environment (고밀 주거환경에서의 사회적 소통을 위한 계획 방향 연구)

  • Lee, Jae-Young;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • The purpose of this study is to present the direction of the plan to transform the residential complex into a space that can provide an open residential environment that can lead to social communication and exchange without being closed to the urban residential environment, especially in the apartment complex environment, which is becoming more dense. As a result of the Openness analysis of the 'Codan Shinonome Canal Court', the overall accessibility was good in terms of space utilization, and the openness was low in terms of the spatial composition, which is a physical environment due to the dense block type. When looking at the overall openness of the Codan Sinonome complex in terms of analysis by block, the corrected openness index (C.O.I) for all six blocks was 0.245, the corrected accessibility index (C.A.I) was 1.447 and the openness composite index (O.C.I) was assessed at 1.692. This was due to the formation of high-density block-type urban dwellings and the introduction of S-shaped streets and the layout of low-rise urban support facilities and commercial facilities. The Codan Sinonome Canal Court, which is considered an "open city residence," quantitatively confirmed that it embodies macro-space structure and human-scale space environment even in high-precision environments.

A Study on the Large Experiments (ISO 13785-2) for Vertical Fire Behavior Analysis of Aluminum Composite Panels in General and Flame-retardant Material (일반재와 난연재 알루미늄복합패널의 수직화재 성상분석을 위한 실대형시험(ISO 13785-2)에 관한 연구)

  • Choi, Chui-Kyung;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.92-98
    • /
    • 2012
  • In this sturdy, large experimental (ISO 13785-2) was performed to analyze the building materials used in fire retardant materials for aluminum composite panel and in general properties. As a results, maximum temperature in the case of the general materials was measured in 210 seconds $1,021^{\circ}C$, the retardant materials was measured in 1,200 seconds early $1,190^{\circ}C$. The retardant material of aluminum composite panel, Fire behavior if the ignition is slow and the general materials in aluminum composite panel, fire ignition and combustion at the same time was growing rapidly. The general materials and flame-retardant material of aluminum composite panel was an obvious difference to the combustion ignition but after ignition combustion mode showed a similar pattern of the rapidly vertical spread of flame. The results of this study, in order to reduce the risk of aluminum composite panels for fire and the retardant materials used for ignition the slow should be actively encouraging. Also after the ignition, there is an urgent need to put out a fire in exterior materials for extinguishing facilities.

A Study on Enhancing Efficiency of the Safety Certification and Diagnosis System for Buildings (건축물의 안전성 관련 인증 및 진단 제도의 효율성 제고를 위한 연구)

  • Sang-Pil Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.73-78
    • /
    • 2023
  • It is very important to evaluate how the functions of products, facilities, and spaces affect human life. The evaluation of these actions has legal regulations such as certification, inspection, and diagnosis, and the degree of quality, safety, and excellence of the results is announced. This study sought to secure safety through efficient system operation by reviewing safety-related certification systems established and implemented by each government department in Korea and analyzing the characteristics of each system and similarities between systems. There was also an aspect of cross-checking safety through the certification and diagnosis system implemented by each ministry, but it was confirmed that the efficiency of the system should also be considered in terms of overlapping application. Therefore, when securing safety is confirmed based on each safety-related law, active alternatives such as exemption, substitution, delegation, etc. should be presented.

Monitoring the Reoccurrence of Fire Blight and the Eradication Efficiency of Erwinia amylovora in Burial Sites of Infected Host Plants Using Sentinel Plants (미끼식물을 이용한 화상병 감염 기주 매몰지 내 화상병균 제거 효율 검증 및 병 재발 모니터링)

  • In Woong, Park;Yu-Rim, Song;Nguyen Trung, Vu;Eom-Ji, Oh;In Sun, Hwang;Hyeonheui, Ham;Seong Hwan, Kim;Duck Hwan, Park;Chang-Sik, Oh
    • Research in Plant Disease
    • /
    • v.28 no.4
    • /
    • pp.221-230
    • /
    • 2022
  • The fire blight caused by Erwinia amylovora (Ea) was first reported in 2015 in Korea, and the disease has rapidly spread to 22 regions until 2021. In Korea, all host plants in the apple and pear orchards where fire blight occurred should be eliminated and buried by the Plant Protection Act. To prevent the spread of the disease, all burial sites were prohibited from planting the new host plants for the next three years. To confirm the eradication efficiency of Ea and the reoccurrence of fire blight, the surveillance facilities were established on three burial sites from 2019 to 2020 in Anseong-si, Gyeonggi-do, and Chungju-si, Chungcheongbuk-do. As host plants, five apple trees of fire blight-susceptible cultivar 'Fuji', were planted in each facility. All facilities were enclosed with fences and nets and equipped with two CCTVs, motion sensors, and several other sensors for recording weather conditions to monitor the environment of the sentinel plants in real-time. The sentinel plants were checked for the reoccurrence of fire blight routinely. Suspicious plant parts were collected and analyzed for Ea detection by loop-mediated isothermal amplification polymerase chain reaction and conventional polymerase chain reaction. Until November 2022, Ea has not been detected in all sentinel plants. These results might support that the burial control of infected plants in soil works efficiently to remove Ea and support the possibility to shorten the prohibition period of host plant establishment in the burial sites.

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.

A Study on the Disaster Prevention Technology of the Switchboard with Upper and Lower Bending Type Seismic Pads (상하굴절형 내진패드를 설치한 수배전반 방재기술에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;Lee, Jaewon;Kim, Taejin;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2017
  • The purpose of this study is to investigate the effect of vertical and horizontal refraction on the lower part of the power supply and control system of various facilities and machinery that use electricity, so that the power distribution system, which is an important electric facility installed in buildings and public facilities, Type earthquake resistant pads to protect the substructure and prevent short-circuiting on the upper part of the system. The GR-63-CORE (Scale 8.3 class) It is earthquake disaster prevention and disaster prevention technology that satisfies seismic performance. As a research result, it is possible to protect the electricity and communication infrastructure, which can contribute to shortening the time for recovering the electric facilities to the normal state in case of an earthquake, and preventing the fire caused by the destruction of the electricity supply facility in case of an earthquake. As a result, it is possible to minimize the spread of fire that occurs when a large-scale earthquake occurs and to minimize the damage of people and damage to property, and it can contribute to the securing of electric infrastructure that enables citizens to quickly recover to daily life even after suffering a major earthquake. In addition, the technology can be applied to ensure the seismic resistance of the equipment in the communication and computer room, and it can be applied to various fields where the facility function can be stopped due to the shaking of the earthquake base.

Improvement of Citadel Structure on Board Ship Using FDS (화재 시뮬레이션을 이용한 선원대피처의 구조 개선에 관한 연구)

  • Kim, Won Ouk;Kim, Jong Su;Park, Woe Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.306-311
    • /
    • 2015
  • Recently, vessel hijacking by pirates has been a big issue around the world. In case of the hostages of M/V "SAMHO Jewelry" on January 20, 2011, the Korean Navy has rescued 21 seafarers by first naval operation with somalia pirates since establishment of the Navy. Also, in case of the "HANJIN Tianjin", all crews evacuated to the Citadel promptly when being attacking by pirates and were safely rescued by the navy. By the accident, Necessity of Citadel for seafarer on board ship came to the fore against pirates. Taking in account increasing pirates accident at sea, many research relating to pirates has been implementing with a view to responding to them so far. By amending the ship facility regulation in the domestic law on Jan. 2011, the installment of Citadel on board ship became mandatory for ocean going vessel serving pirates area. Hence, this paper provides new model of Citadel structure based on an Fire Dynamic simulation in order to improve personal safety in case of vessel hijacking.

A Study on the Analysis and Protection of Lightning Accident in Petrochemical Plant Wastewater Storage Tank (석유화학공장 폐수 저장 탱크의 낙뢰사고 분석과 보호방안에 관한 연구)

  • Song, Bang-Un;Oh, Gil-Jung;Woo, In-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.107-113
    • /
    • 2019
  • Recently, due to global warming, the trend shows an increase in number of lightning strikes which increase risk regarding industry infrastructures. Especially in case where the lightning strikes infrastructures including refinery, petorchemical plant facilities or storage tanks, it can cause power failures, electrical machine malfunction and damage which can lead to fire explosion and multiple calamities. Therefore, detailed case studies must be conducted through a systematic research regarding lightning strike accidents in order to understand its mechanism and devise preventive measures. This paper aims to study cases of explosion regarding waste water storage tanks in refineries and petrochemical plants in order to analyze its root cause and provide preventive measures for avoiding lightning related incidents.