• Title/Summary/Keyword: Fire protection Facilities

Search Result 194, Processing Time 0.024 seconds

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care (노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.50-59
    • /
    • 2018
  • Recently, huge life losses occurred in the elderly long-term medical care fires due to lack of escape safety. As part of the measures to enhance the effectiveness of fire escape safety, while they prolong the available safe egress time (ASET) of non fire compartments, a measure to shorten fire-fighter's arrival time by fire alarm notifying device should be implemented in these facilities. The four categories from the aspects of fire prevention/protection engineering were provided with the necessary component technologies for carrying out these helper-guided evacuations. Fire prevention engineered technology was presented by two provisions; one for ensuring small compartment sections by installing the fire rated wall between bed rooms and another for ensuring the fire retardant or/and non-flammable performance of finishing materials. Also fire protection engineered technology was presented by two items; one for imposing cooling effects by sprinklers and another for providing automatic fire alarm notifying functions to fire stations. In order to improve the escape safety of these facilities in Korea, alternative revisions may presented by considering insufficient provisions in the architectural/fire law provisions by analyzing the provisions of Japanese and domestic laws in detail.

A Study on the Improvement of Dangerous Goods Safety Management in Maritime Terminal (항만 옥외저장소 위험물의 안전관리 개선 방안)

  • Lee, Bong-Woo;Shin, Se-Cheol;Park, Kyung-Jin;Choina, Yeong-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.393-401
    • /
    • 2020
  • According to the research and investigations performed on Port Facilities for cargo-works of hazardous materials around the Port of Busan, a conclusion was drawn that the manually operating foam tower monitors are ineffective as they are hard to access due to the radiant heat under contingency circumstances such as a fire. Moreover, in some cases, the effective range of Foam Tower Monitors are insufficient to reach docked ships and manifolds where hazardous materials are being unloaded. In addition, Dangerous Goods freights are inadequately and inefficiently stored regardless properties of hazardous substances due to complicated local regulations, and some are equipped with inapplicable facilities for docked ships. Therefore, in order to effectively counteract the contingencies and obtain safety, it would be recommended to install adequate facilities.

Analysis on Shielding Effectiveness of Electromagnetic Wave in Fire Pipes (물이 채워진 소화 배관의 전파 차폐도 해석)

  • Kim, Yoon-Jeung
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.94-102
    • /
    • 2016
  • When establishing shielding facilities for EMP protection, WBC effect is used to protect fire pipes and honeycomb cells are inserted into the fire pipes to improve the shielding effectiveness. At this point, the smaller unit cell of honeycombs becomes, the more likely it interrupts the flow of water, which ends up clogging the fire pipes with sediment. To prevent this phenomenon, I would suggest a design method due to the pilarization loss of water molecules that contributes to increasing the size of honeycomb cells and remaining thin-walled sufficient for required shielding effectiveness.

A Study on Fire and Evacuation in the Public Relations Room of Waste Treatment Facilities (폐기물 처리시설 홍보실내 화재 및 피난에 관한 연구)

  • Lee, Jae-Young;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.17-22
    • /
    • 2021
  • The public relations room of the waste disposal facility is a space that can be visited by a large number of unevaluated personnel. Therefore, it is essential to design against fire, and research on fire and evacuation is essential. In this study, in order to evaluate the safety of the occupants in the event of fire and evacuation based on the life safety standards of occupants, the increase in risk due to heat, visible distance, and toxic gases on a plane 1.8m from the floor, which is the limit of breathing of the evacuee, over time. It was analyzed by location. As a result, the RSET of the P-01 exit was 93.0 seconds and the ASET was 272.6 seconds, the RSET of the P-02 exit was 45.8 seconds, the ASET was 147.7 seconds, the RSET of the P-03 exit was 106 seconds, and the ASET was 182.9 seconds.

A Study on the Fire Safety Measure of Pumped Storage Power Plant (양수발전소의 화재안전 대책에 관한 연구)

  • Kim, Yoo-Shik
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.125-130
    • /
    • 2006
  • Pumped storage power plant is a system of generating electricity with hydroelectric power, in which at times of low electrical demand such as during nights, excess generation capacity of many power plants is used to pump water into the higher reservoir, and when there is higher demand, water is released back into the lower reservoir through a turbine, generating electricity. As pumped storage power plants across the nation are not on building registry under "the Article 6 of the Special Act by the Development of Power Resources", they are classified as a structure, not as a building. As a result, permit of fire protection facility is unnecessary, and fire protection administration is excluded from approval to completion of construction. Therefore, this study is to improve problems in accordance with the application of "he Article 6 of the Special Act by the Development of Power Resources", repair of facilities and problems with safety control to effectively prevent similar damages from repeatedly happening to pumped storage power plants in operation or under construction nationwide during a fire.

A Study on Damage Assessment for Fuel Cell Facilities in Gas Stations (주유소 내 연료전지설비에 대한 사고피해예측 연구)

  • Sung Yoon Lim;Jang Choon Lee;Jae Hoon Lee;Seung Ho Choi
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.1
    • /
    • pp.71-80
    • /
    • 2023
  • Fuel cells are low-carbon power sources that can expand distributed energy system and electric vehicle charging infrastructure when installing fuel cells in gas stations. In order to ensure safety for fuel cells in gas stations, quantitative risk assessments were conducted after deriving accident scenarios based on accident data of domestic and foreign gas stations and fuel cells. It calculates the expected extent of damage from fire and explosion that can occur in reality, not the worst accident scenario, and analyzes the damage impact. The separation distance of more than 9.0 m from a dispenser, 15.5 m from a car under refueling, 4.1 m from the ventilation pipe, 1.1 m from the gas adjustment device prevent the severe damage caused by the expected accident. This study result can be used to deploy fuel cells in gas stations and establish safety measures.

A Study on the Analysis of Operation Reliability of Fire Doors and Fire Shutters Using Fire Statistical Data (화재통계자료를 활용한 방화문, 방화셔터 작동신뢰성 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.119-120
    • /
    • 2020
  • In order to establish an evaluation method that can quantitatively evaluate the fire safety of existing buildings in Korea, a stochastic approach is needed to consider the extent of damage in the event of actual fire, along with the operation and installation of facilities. Accordingly, as a basic study for the establishment of fire safety assessment methods for buildings, this study aims to analyze the results of safety inspection and the degree of damage caused by the operation of fire doors and fire shutters in order to derive the reliability of fire doors and fire shutters. As a result, the results of inspection of fire shutters and fire doors and the results of operation using fire statisticians are as follows. As a result of the inspection, the positive rate of fire doors was about 82% and 98% of normal operation was derived from the fire investigation.

  • PDF

A Study on the Basic Investigation for the Fire Risk Assessment of Education Facilities (교육시설 화재위험성 평가를 위한 기초조사에 관한 연구)

  • Lee, Sung-Il;Ham, Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.351-364
    • /
    • 2021
  • Purpose: Fire load analysis was conducted to secure basic data for evaluating fire risk of educational facilities. In order to calculate the fire load through a preliminary survey, basic data related to the fire load of school facilities were collected. Method: The basic data were the definition and types of fire loads, combustion heat data for the calculation of fire loads. The fire load was evaluated by multiplying the combustion heat by the weight of the combustibles in the compartment when calculating the fire load. Result: As for the fixed combustible materials of A-elementary school, the floor was mainly made of wood, in consideration of emotion and safety in the classroom, music room, and school office, and the rest of the compartments were made of stone. The ceiling and walls were made of gypsum board and concrete, so they were not combustible. The typical inflammable items in each room were desks, chairs, and lockers in the classroom, and the laboratory equipment box and experimental tool box were the main components in the science room, and books, bookshelves, and reading equipment occupied a large proportion in the library room. Conclusion: 'The fire loads of A-elementary' schools according to the combustibles loaded were in the order of library, computer room, English learning room, teacher's office, general classroom, science hall, and music room.

A Study to Prevent the Forest Fire in Forest Facilities and Forests (산림과 산림시설물의 산불 피해 예방에 관한 고찰)

  • Park, Kyong-Jin;Kim, Hye-ree;Lee, Bong-Woo;Park, Shin-young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.301-306
    • /
    • 2020
  • In this study, analyzed national forest fire statistics by cause, year, region, and damage scale based on the National Fire Data System. as a result, the main cause of forest fires was the most frequent human error. forest fires occurred in areas with high population density. and it was confirmed that the Widest area of forest damage was Gang-Won province, which is rich in forestry resources. by season, it occurred a lot in spring because of the warm temperature and strong wind and low humidity. such disasters directly damage forest facilities such as house and cultural properties as well as destruction of natural resources. therefore in this study, made a suggestion plan for prevention from forest fire with forest fire prevention comprehensive plan of MFOA.