• Title/Summary/Keyword: Fire occurrence

Search Result 431, Processing Time 0.026 seconds

A Study on Flame Retardant Characteristics of Wood Finished with Painting (단청목재의 방염특성에 관한 연구)

  • Kim, In-Beom;Hyun, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.184-188
    • /
    • 2008
  • This study was carried out to investigate the flame retardant characteristics of wood finished with painting by followed in exposure conditions and flame retardant application method. According to painting types and flame retardant application methods salting occurrences undergoing an influence about the wood finished painting, confirmed. And influence to flame retardant characteristics of exposure condition on large scale not to be and occurrence quantity of the combustion gas undergone and influence In application method of flame trtardant.

  • PDF

A Study on the Mechanism of Explosive Spalling and Spalling Prevention Methods of High-Strength Concrete in Fire Temperature (고강도 콘크리트의 폭렬발생 및 폭렬저감 메커니즘에 관한 문헌적 고찰)

  • Jung, Hee-Jin;Lee, Jae-Young;Kim, Jae-Hwan;Han, Byung-Chan;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.313-316
    • /
    • 2008
  • Nowadays, the use of high strength concrete has become increasingly popular. Thus, the theory of this study gives a definition of HSC mechanism through study factors of spalling occurrence of HSC and solutions of failure mechanism. During the fire goes on, building structure using HSC causes explosive spalling and finally it gets to the breaking of the structure down. As a result of this failure mechanism, it remains to be investigated to prevent from explosive spalling of HSC and needs to provide basic problems of HSC at high temperature.

  • PDF

A study on the confrontation plan of accident through the subway fire instance analysis (지하철 화재 사례분석에 따른 사고대응방안에 대한연구)

  • Kim Myeong-Kyu;Han Seong-Ho;Kim Hag-Reon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.997-1004
    • /
    • 2005
  • Representative of Korean accidents is that occurrence number of accidents is not many. But the extra-large size disaster like as Taegu subway accident are occurred continuously from multi place. It brings a big problem that people has spirit shock and a life damage nationally and socially. The problem point which brings like this tragic death is caused from the fire confrontation system of absent and human confrontation mistake. Therefore, we need the confrontation plan to overcome these accidents. It will be able to prepare favorably in accident confrontation. In this paper, we analyzed fire accidents case study on domestic and oversea and proposed the plan which confronts encounter to fire accidents in subway system urgently and properly.

  • PDF

Experiments of Smoke Behavior in an Underground Subway Station (지하역사에서의 화재연기거동 실험)

  • Kim, Dong-Hyeon;Jang, Yong-Jun;Park, Won-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.1 s.38
    • /
    • pp.67-73
    • /
    • 2007
  • Experiments were carried out to investigate smoke movement in platform of a subway station which currently is in service in Pusan, the second largest city in Korea. The recently constructed underground station of the "bank type" (two platforms on both sides of track) which is the popular layout of platforms in Korea, is chosen in Pusan. The smoke generator and heater are used for simulating the smoke movement at the fire break in the platform located in the 2nd basement of the station. Video recordings were used to monitor smoke lowering. In this study, the movements of smoke in the underground station are investigated under various smoke-control operating modes. Three tests wire conducted according to its operating mode of the ventilation systems in the platform: no operation of any ventilation systems, smoke extraction mode in occurrence of fire (presently running mode) and full capacity of smoke extraction where all vents are activated in the platform. The results can be used for comparing with the numerical prediction results of fire subway stations.

A Study on the Design of Microcomputer Processor Algorithm for Electrical Fire Prediction (전기화재 예측을 위한 마이컴 프로세서 알고리즘 설계에 관한 연구)

  • Kwak, Dong-kurl;Choi, Jung-Kyu;Lee, Bong-Seob;Choi, Shin-Hyeong
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.11-12
    • /
    • 2015
  • This study has looked into ways to cut the power supply by predicting electrical fire that may occur in low-voltage cable, which is most frequently used in industrial settings and households. In addition, we have designed a system that cuts off electricity to prevent the fire upon occurrence of events that may cause electrical fire, including short circuit, tracking and contact failure. A lot of previous researches have designed arc suppressors built in analog circuit, which left much to be desired such as difficulty in remote control and inability to identify the location of arc suppressor when it is activated. To address these issues, the study seeks to develop an arc suppressor using micom and to verify its performance through simulations designed to detect arc faults.

  • PDF

Establishment of the Method for Evaluating the Risk of Fire Spread to the Upper Floors due to Ejected Flame from an Opening in the Building Fires (건축물 화재시 개구분출화염으로 인한 상층부로의 화재확대 위험성평가 방법 구축)

  • Shin, Yi-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.216-217
    • /
    • 2020
  • As the fire inside the building grows rapidly, ejected flame from an opening occurs due to flashover. As a result, the number of cases where the flame spreads to the exterior of the building and rapidly expands to the upper floor is increasing. In particular, in the case of the fire in the Daebong Green Apartment, Uijeongbu in 2015, it was a case where the flame spread to adjacent buildings due to the opening eruption flame from the first ignited building, causing great damage to three apartments. Therefore, this study is to introduce an international standard under development that estimates the shape and properties of the ejected flame from an opening and quantitatively evaluates the radiant heat flux received by the exterior wall of the building by assuming the occurrence of the ejected flame from an opening.

  • PDF

Improvement of Fire Detection in Rack-type Warehouses using FDS (FDS를 이용한 랙크식 창고의 화재감지 개선에 관한 연구)

  • Choi, Ki-Ok;Park, Moon-Woo;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.55-60
    • /
    • 2019
  • The occurrence of fire in rack-type warehouses may either lead to the warehouses getting entirely burned up or collapsing. This can be attrubuted to the high height of rack-type warehouses, in which combustibles are generally vertically stacked. These characteristics make it difficult to detect a fire early; because detectors are installed on the ceiling, these fires cannot be extinguished at an early stage. In this study, the flow of heat and smoke generated by a fire in a rack-type warehouse was analyzed using a fire dynamic simulator. Through this analysis, the optimal installation conditions of fire detectors for the early detection of fire in rack-type warehouses were confirmed. The analysis results confirmed that complex detection of heat and smoke is required for the early detection of fire in rack type warehouses. Furthermore, it was found that fixed temperature detectors are not suitable for these warehouses, resulting in the need to install heat-smoke hybrid detectors at every three rack levels.

A Study on a Development of Automated Measurement Sensor for Forest Fire Surface Fuel Moistures (산불연료습도 자동화 측정센서 개발에 관한 연구)

  • YEOM, Chan-Ho;LEE, Si-Young;PARK, Houng-Sek;WON, Myoung-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.6
    • /
    • pp.917-935
    • /
    • 2020
  • In this study, an automated sensor to measure forest fire surface fuel moistures was developed to predict changes in the moisture content and risk of forest fire surface fuel, which was indicators of forest fire occurrence and spread risk. This measurement sensor was a method of automatically calculating the moisture content of forest fire surface fuel by electric resistance. The proxy of forest fire surface fuel used in this sensor is pine (50 cm long, 1.5 cm in diameter), and the relationship between moisture content and electrical resistance, R(R:Electrical resistance)=2E(E:Exponent of 10)+13X(X:Moisture content)-9.705(R2=0.947) was developed. In addition, using this, the software and case of the automated measurement sensor for forest fire surface fuel moisture were designed to produce a prototype, and the suitability (R2=0.824) was confirmed by performing field monitoring verification in the forest. The results of this study would contribute to develop technologies that can predict the occurrence, spread and intensity of forest fires, and are expected to be used as basic data for advanced forest fire risk forecasting technologies.

A Study on Introduction of Student Volunteer Fire Department in Dormitory far from Fire Station (근접성이 불리한 대학 기숙사의 학생 의용소방대 도입에 관한 연구)

  • Baek, Doo-San;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.65-69
    • /
    • 2015
  • The university dormitory have various functions and large floating population so in the occurrence of fire, there could be heavy casualties. Also, when university dormitory is located far from fire station, it is difficult to fire brigade arrives on Golden Time. Therefore, university dormitory need response capabilities for fire by itself. This study conducted a simulation experiment on those residing in K University dormitory in Gangwon-do, where site proximity is unfavorable, to observe evacuation characteristics of the occupants. As a result, evacuation is delayed due to a lack of evacuation routes and administrator, some students lack of fire awareness. Also fire brigade didn't arrive on Golden Time. Therefore, to resolve problems it is proposed that a student fire volunteer department.

Investigating the Effect of Prior Damage on the Post-earthquake Fire Resistance of Reinforced Concrete Portal Frames

  • Ronagh, Hamid Reza;Behnam, Behrouz
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.209-220
    • /
    • 2012
  • Post-earthquake fire (PEF) can lead to a rapid collapse of buildings that have been partially damaged as a result of a prior earthquake. Almost all standards and codes for the design of structures against earthquake ignore the risk of PEF, and thus buildings designed using those codes could be too weak when subjected to a fire after an earthquake. An investigation based on sequential analysis inspired by FEMA356 is performed here on the immediate occupancy (IO), life safety (LS) and collapse prevention (CP) performance levels of two portal frames, after they are pushed to arrive at a certain level of displacement corresponding to the mentioned performance level. This investigation is followed by a fire analysis of the damaged frames, examining the time taken for the damaged frames to collapse. As a point of reference, a fire analysis is also performed for undamaged frames and before the occurrence of earthquake. The results indicate that while there is minor difference between the fire resistances of the fire-alone situation and the frames pushed to the IO level of performance, a notable difference is observed between the fire-alone analysis and the frames pushed to arrive at LS and CP levels of performance and exposed to PEF. The results also show that exposing only the beams to fire results in a higher decline of the fire resistance, compared to exposing only the columns to fire. Furthermore, the results show that the frames pushed to arrive at LS and CP levels of performance collapse in a global collapse mode laterally, whereas at the IO level of performance and fire-alone situation, the collapse mechanism is mostly local through the collapse of beams. Whilst the investigation is conducted for a certain class of portal frames, the results confirm the need for the incorporation of PEF into the process of analysis and design, and provide some quantitative measures on the level of associated effects.