• Title/Summary/Keyword: Fire location

Search Result 384, Processing Time 0.028 seconds

Numerical Investigation on Fire of Stage in Theater: Effects of Natural Smoke Vent Area and Fire Source Location (공연장 무대부 화재에 대한 전산해석 연구: 자연 배연구 면적과 화원 위치 영향)

  • Park, Min Yeong;Lee, Chi Young
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • This numerical study investigates the effects of the size of the natural smoke vent area (10% and 1% of the floor area) and the location of the fire source (i.e., at the side and center of the stage) on the temperature distribution in the compartment and velocity distribution and mass flow rate of flow through a natural smoke vent for a reduced-scale model of a theater stage. Then, the mass flow rate of outflow through the natural smoke vent in the event of a fire for a real-scale theater stage was examined. The case with the larger natural smoke vent area and central fire source location showed lower temperature distributions and higher mass flow rates of outflow and inflow than the case with the smaller natural smoke vent area and side fire source location. The trends of the temperature distributions were closely related to those of the mass flow rates for the outflow and inflow. Additionally, the case with the larger natural smoke vent area and central fire source location exhibited the most non-uniform flow velocity distribution in all cases tested. A bidirectional flow, in which the outflow and inflow occur simultaneously, was observed through the natural smoke vent. In the event of a fire situation in a real-scale theater stage, it was predicted that the case with the larger natural smoke vent area and central fire source location would have a mass flow rate of outflow that is 43.53 times higher than that of the case with the smaller natural smoke vent area and side fire source location. The present results indicate that the natural smoke vent location should be determined by considering the location in a theater stage where a fire can occur.

Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver (재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Yang, Seung-Hyun;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

THE STUDY ON THE CHARACTERISTICS OF FIRE DRIVEN SMOKE-FLOW FOR DIFFERENT FIRE-LOCATION IN DEEPLY UNDERGROUND SUBWAY STATION (대심도 지하역사에서 화원 위치에 따른 연기거동 특징 연구)

  • Kim, H.B.;Jang, Y.J.;Lee, C.H.;Jung, W.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.202-207
    • /
    • 2009
  • In this study, Numerical simulations were performed to analyze the characteristics of fire driven smoke flow for different location of fire source in the deeply underground subway station with using FDS code. The fire driven smoke-flow which was simulated by using Parallel Computational Method for fast calculation and LES for turbulence model. In this research, the fire location to obstruct a suitable egress from the fire disaster were discussed.

  • PDF

The Study for the Optimal Location of Fire Stations in Seoul (서울시의 소방서 최적입지에 관한 연구)

  • Kim, Geun-Young;Kang, Sung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.153-159
    • /
    • 2002
  • Disasters are the phenomena that we have to prevent the occurrence in order to keep the safety to human lives and properties, and if occurred, we have to minimize the economic, social, and mental costs of the occurred disasters or incidents. This research analyzes the optimal location of fire stations in terms of served population maximization in Seoul. This research introduces "the maximal covering location problem(MCLP)," one of the optimization techniques, as the primary research method. This research also applies a geographic information system into spatial distribution analyses of existing fire stations and observed fire incidents. Results from the analyses show that the existing location of fire stations and branches need to be improved. The dispatch location of fire engines should be reconsidered for rapid services of fire fighting.

Development of a Server-independent System to Identify and Communicate Fire Information and Location Tracking of Evacuees (화재정보 확인과 대피자 위치추적을 위한 서버 독립형 시스템 개발)

  • Lee, Chijoo;Lee, Taekwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.677-687
    • /
    • 2021
  • If a fire breaks out in a building, occupants can evacuate more rapidly if they are able to identify the location of the fire, the exits, and themselves. This study derives the requirements of system development, such as distance non-limitation, a non-additional device, a non-centralized server system, and low power for an emergency, to identify information about the fire and the location of evacuees. The objective is to receive and transmit information and reduce the time and effort of the database for location tracking. Accordingly, this study develops a server-independent system that collects information related to a building fire and an evacuee's location and provides information to the evacuee on their mobile device. The system is composed of a transmitting unit to disseminate fire location information and a mobile device application to determine the locations of the fire and the evacuee. The developed system can contribute to reducing the damage to humans because evacuees can identify the location of the fire, exits, and themselves regardless of the impaired server system by fire, the interruption of power source, and the evacuee's location. Furthermore, this study proposes a theoretical basis for reducing the effort required for database construction of the k-nearest neighbor fingerprint.

GIS Application for 1-1-9 Caller Location Information System (GIS를 이용한 신고자 위치표시 시스템 개발)

  • Hahm, Chang-Hahk;Jeong, Jae-Hu;Ryu, Joong-Hi;Kim, Eung-Nam
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.8 no.1 s.15
    • /
    • pp.97-103
    • /
    • 2000
  • The main purpose of 1-1-9 Caller Location Information System is to identify and display the precise location of emergency incidents such as natural or man - made fires, medical emergencies and accidents. The state - of- the - art technologies such as Am (Automatic Number Identification), GIS(Geographical Information System) and GPS (Global Positioning System) were applied and integrated in the system for efficient and effective location identification. It displays a radius of 25M, 50M and 100M on the map after location identification. The system can also provide the shortest path to an incident location from a fire station or a fire engine. In case of a fire breakout in or near a building, the attribute information of the building, called a building attribute card, is displayed along with the map location. The system then matches the information with the fire situation and sends an alert to a responsible fire station by phone or fax in order to help promptly react to the problem. An attribute card includes the critical information of a premise such as building's location, number of stories, floor plans, capacity, construction history, indoor fire detection and Prevention facilities, etc.

  • PDF

A Study on the Use of Wireless Signals of Mobile Phones for Effective Rescue Activities at Fire Sites (화재 현장에서 효과적인 구조활동을 위한 휴대전화의 무선 신호 활용 방안 연구)

  • Kim, Younghyun;Kim, Boseob;Jung, Jongjin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.235-236
    • /
    • 2021
  • As a result of analyzing the fire accident of the Jecheon complex that occurred at the end of 2017, there have been many casualties due to delays in checking the location information of isolated people. In order to prevent such an accident, various research has been conducted to estimate the location of requesters by means of detecting wireless communication information of mobile phones existing at disaster sites. The main concept is to detect an RF signal of a mobile phone at fire sites and, based on this, precisely estimate the location of the mobile phone on the LOS/NLOS. However, it is difficult to get visibility at fire sites due to smoke and the fire. Therefore, apart from estimating the location of requesters, a research is also needed to determine the direction of entry within fire sites. In this paper, we propose a method to determine a direction of entry to provide effective rescue activities using wireless communication information of mobile phones.

  • PDF

A Study on the Prediction of Combustion Gas Behavior Induced by Fire in a Building (건물내 화재에 의한 연소가스 거동 예측에 관한 연구)

  • Pak, H.Y.;Park, K.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.267-281
    • /
    • 1994
  • The Combustion gas behavior induced by fire in a building is numerically investigated. The typical building for this analysis is partially divided by a vertical baffle projecting from the ceiling. The solution procedure includes the low Reynolds number ${\kappa}-{\varepsilon}$ model for the turbulent flow and the discrete ordinates method is used for the calculation of radiative heat transfer equation. The effects of the location and size of fire source and baffle length on velocity and temperature distributions, species mass fraction and flame location are analyzed. As the results of this study, it is found that the case when the fire source is located at the vertical wall is more dangerous than at the bottom wall in view of the combustion products and flame location. It is also found that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF

A Numerical Study of the Backdraft Behavior with the Variation of the Ignition Location and Time (점화원 위치 및 점화시간 변화에 따른 백드래프트 거동에 관한 수치적 연구)

  • Ko, Min Wook;Oh, Chang Bo;Han, Yong Shik;Do, Kyu Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.1-8
    • /
    • 2016
  • The behavior of backdraft in the compartment with different ignition locations and times was numerically investigated. The Fire Dynamics Simulator (FDS) v5.5.3 with a model-free simulation option was used in the numerical simulation of backdraft. The ignition source was located near the inside wall, at the compartment center and near the window opening, respectively. The ignition was started at the instance when the fresh air reached the ignition location or when a sufficient time passed compare to the instance of the arriving of the fresh air to the ignition location. As a result, for the ignition source was located near the inside wall, a strong fire ball was observed at once and the result was similar to the previous experimental result. For the ignition source was located at the center of the compartment, a strong fire ball was occurred and two strong fire balls were observed consecutively for the ignition time was delayed. For the ignition source was located near the window opening and longer time was given for the ignition compare the duration of the fresh air arriving to the ignition location, the rapid temperature variation was not observed because there was no flame. However, for the ignition was started at the instance when the fresh air reached the ignition location, the ignition could be initiated and a intensive fire ball was observed. The pressure measured at the upper inside part of the window opening provided a similar trend with the previous experimental result of compartment backdraft.

Analysis of Smoke Spread Effect Due to The Fire Location in Underground Subway-Station (대심도 역사의 화재위치에 따른 연기확산 영향 분석)

  • Jang, Yong-Jun;Koo, In-Hyuk;Kim, Jin-Ho;Nam, Seong-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2885-2890
    • /
    • 2011
  • Simulation study were performed for fire location effect on the smoke spread in the deeply-underground subway station(DUSS). In this research, Shingumho station (The line # 5, Depth: 46m) has been selected as case-study for the analysis of smoke-spread effect with the different fire location. Field test data measured for actual fan in DUSS was applied as a condition of a simulation. The whole station was covered in this analysis and 4 million grids were generated for this simulation. The fire driven flow was analyzed case by case to compare the smoke-spread effect according to the fire location. In order to enhance the efficiency of calculation, parallel processing by MPI was employed and LES(large eddy simulation) method in FDS code was adopted.

  • PDF