• 제목/요약/키워드: Fire gas

검색결과 1,031건 처리시간 0.034초

기존 건축물을 용도변경한 노인의료복지시설의 화재 인명피해 예방과 피난 대책 -광주·전남 농촌지역을 중심으로- (Prevention of Human injury and Countermeasure of evacuation about Fire of Nursing Homes by Conversion of existing buildings - Focused on rural areas in Gwangju and Jeonnam -)

  • 김현태;김원진
    • 한국농촌건축학회논문집
    • /
    • 제20권1호
    • /
    • pp.27-36
    • /
    • 2018
  • At present, the elderly population in Korea is 14% of the total population and then We has entered an the society of advanced age. Along with this, elderly people with dementia and palsy are also increasing. The demand for elderly nursing homes for elderly people with severe diseases such as dementia and stroke is also increasing, and the existing buildings are being secured by Conversion of existing buildings. However, it is difficult to evacuate and fire due to the out of date of buildings by Conversion of existing buildings. For example, there is a fire in the Indukukwon, Pohang City and Hyosung Geriatric Hospital, Jangseong in Korea, which have changed the use of existing buildings. Many elderly people died in a night fire. It was because of the sandwich panel walls and PVC flooring material produced toxic gas instantly. In this study, we investigated the nursing home that changing the use and established fire prevention of human injury and countermeasure of evacuation. First, the sandwich panels which leading to deaths due to the toxic gas were installed in most nursing home. We recommend the RC, the masonry wall, and the glass fiber panel instead of the sandwich panels, In addition, the PVC flooring is most used in nursing home, the flooring material is considered such as the building stones, the tile, and the yellow soil closing instead of the PVC flooring. Second, we investigated the installation status of fire fighting equipment. As a result, the automatic-emergency open&shut equipment, the smoke ventilator and the evacuation slide were rarely installed. In order to secure the golden time in case of fire and to prevent the asphyxia caused by the toxic gas, the law should be amended to install the equipment.

중규모 도로터널의 제연경계벽 설치에 따른 연기확산특성 (Study of the Characteristics of Smoke Spread by an Installing Smoke Barrier in Medium Length Road Tunnel)

  • 백두산;이승철
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.9-17
    • /
    • 2016
  • 중규모 도로터널의 경우 제연설비 설치가 의무화 되어있지 않기 때문에 화재가 발생할 경우 이용객들이 많은 피해를 입을 수 있다. 따라서 본 연구에서는 연장 1,000 m 2차로 일방통행방식의 도로터널을 대상으로 3차원 수치해석, 정량적 위험도 평가를 통해 제연경계벽이 설치되지 않을 때와 설치간격이 100, 150, 200, 250 m일 때 화재에 의하여 발생되는 연기류 등이 시간에 따른 확산을 분석하였다. 그 결과 중규모 도로터널에 제연경계벽을 설치할 경우 설치하지 않은 경우보다 화재로부터 발생되는 고온의 공기와 독성가스의 확산이 지연되는 것을 확인할 수 있었다. 또한 수치해석 대상 중에서 제연경계벽의 설치간격이 100 m인 경우 화재로 인해 발생된 고온의 공기와 독성가스의 확산이 다른 경우보다 많이 지연되어 터널 이용객이 피난하는데 가장 적합한 것으로 나타났다.

LNG 저장 탱크의 Pool Fire에 의한 복사열 피해 (Radiation Damage by the Pool Fire of LNG Storage Tank)

  • 손정환;한윤봉
    • 한국가스학회지
    • /
    • 제2권1호
    • /
    • pp.14-22
    • /
    • 1998
  • 본 연구에서는 LNG 저장탱크에서 액면화재(pool fire) 발생시 복사열속(radiation flux)의 정량적인 예측과 복사열 피해를 줄이는 방법을 제안하기 위하여 RISC모델을 사용하여 여러 조건에서 복사열속을 계산하였다. 모델 예측결과 LNG 탱크의 액면화재에 의한 복사열 피해에 가장 큰 영향을 미치는 인자는 풍속임을 알 수 있었다. 화염과 피해 대상물사이의 복사피해 정도는 높은 풍속에서 보다 낮은 풍속에서의 풍속변화에 따라 크게 변하였다. 또한 액면화재 발생시 복사열 피해는 탱크 또는 공장 주위에 방풍시설을 함으로써 크게 줄일 수 있음을 알 수 있었다. 방풍시설은 다른 방법들 보다 경제적이기 때문에 냉각시설 및 소방시설과 연계하여 가스 저장탱크 주위에 설치하는 것이 바람직하다.

  • PDF

가스소화약제 압력누기감시장치의 안전성 분석을 위한 수치적 연구 (A Numerical Study to Analyze Safety of Pressure Leakage Monitoring System of Gas Extinguishing Agent)

  • 고아라;임동오;손봉세
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.103-110
    • /
    • 2016
  • 가스계소화설비의 수요는 매해 증가하고 있으나, 늘어나는 수요에 대비한 시스템의 안전성 및 신뢰성등 소화성능에 필요한 안전대책이 미흡하여 사회적인 문제가 되고 있는 실정이다. 본 연구에서는 이러한 문제점을 해결하기 위하여 가스 소화시스템의 사고발생 원인 중에서 가장 심각한 문제인 소화약제 저장용기에서 발생하는 압력누기는 화재진압의 성패를 좌우하는 중요한 요소로 시급한 대책이 요구되는 문제점로 판단하여 연구를 하였다. 새로 개발한 압력누기감시장치는 화재진압에 중요한 요소인 소화농도와 관련이 있는 저장용기의 약제확보상태와 압력 및 누기, 방출상태 등을 감시하는 장치로 $CO_2$와 HFC-23 시스템에 적용할 수 있도록 개발하였다. 즉, 압력누기감시장치를 가스소화설비에 적용하였을 때 발생할 수 있는 구조적 안전성 분석을 위하여 유체-구조연계해석을 통하여 안전성능을 검증하였다. 해석에 사용한 프로그램으로 전산유체해석은 Mentor Graphics사의 FloEFD 프로그램을 사용하였고, 구조해석 프로그램은 Dassault systems사의 ABAQUS를 사용하였다. 수치해석결과 $CO_2$용의 구조에서는 소성변형이 발생하지 않아 안전성을 확인하였으나 HFC-23용 감시장치에는 소성변형 및 이탈문제가 발생하여 설계수정과 3차례의 수치해석 조건을 수정하여 얻은 데이터를 기본으로 압력누기감시장치의 구조적인 안전성을 확인하였다.

플레어스택의 정량적인 복사열 분석 (Quantitative Analysis of Thermal Radiation in Flare Stack)

  • 정상용;이헌석;김범수;유진환;박철환;고재욱
    • 한국가스학회지
    • /
    • 제14권1호
    • /
    • pp.37-41
    • /
    • 2010
  • 공정내의 가연성 혹은 독성가스를 연소시켜 안전한 물질로 전환시키는 것을 목적으로 플레어시스템이 설치되어 있다. 플레어시스템은 공정의 안전성 향상을 위하여 폐가스의 안전한 연소가 가장 중요한 요소이다. 연소의 복사열이 공정의 위험요인이 되지 않도록 API 521 Code에 규정되어 있다. 플레어스택에서 발생하는 화염의 형상은 방출되는 가스의 압력과 질량유속에 의하여 jet fire의 형상을 하고 있으며, 이를 API 521 Code 방식이 아닌 Chamberlain Model을 이용하여 화염의 형상을 확인하고, 이로 인한 복사열을 분석하였다.

카본블랙 제조공정의 안전성 향상에 관한 연구 (A Study on the Safety Improvement of Carbon Black Manufacturing Process)

  • 주종율;정필훈;이성은
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.153-161
    • /
    • 2023
  • Carbon black is a material in the form of fine black powder obtained by incomplete combustion or pyrolysis of hydrocarbons, and is composed of 90-99% carbon, and the rest is composed of hydrogen and oxygen. In the event of an emergency during the manufacture of carbon black, the generated tail gas should be safely discharged through an emergency line to prevent fire, explosion, and environmental pollution accidents caused by the tail gas. If the pressure continues to rise, the pressure control valve shall operate and the rupture plate shall be ruptured sequentially and the tail gas shall be discharged to the vent stack through the emergency line. As an emergency emission system, even if some untreated substances in the tail gas are released into the atmosphere, they are lighter than air, so it is safe to discharge them to a safe place through the Vent Stack. If the gas pressure is rising or worse, it is discharged from the Vent Stackine, and discharging fuel.

LNG 저장탱크 강재지붕의 충격 및 화재에 대한 안전성평가기법 개발 (Development of Impact and Fire Hazard Analysis on the Steel Roof of LNG Storage Tank)

  • 이승림;박장식;이영순
    • 한국가스학회지
    • /
    • 제13권1호
    • /
    • pp.34-39
    • /
    • 2009
  • 지금까지 한국에 도입된 LNG 저장탱크의 지붕형식은 지상식 탱크 및 지중식 탱크를 막론하고 모두 콘크리트 지붕형이었다. 그러나 저장탱크의 대형화와 경제성 측면에서의 장점으로 강재 지붕형 탱크의 도입이 적극적으로 검토되고 있다. 본고에서는 최적 설계된 200,000$k{\ell}$ 강재 지붕형 LNG 저장탱크의 강재지붕에 대한 충격 및 화재 안전성 평가기법을 개발하여 이를 표준화하고 기존의 콘크리트 지붕형 탱크와 비교 평가함으로써 강재 지붕형 탱크의 충격 및 화재에 대한 정량적인 안전성 자료를 확보하였다. 각각 도출된 4가지의 충격하중 및 화재 시나리오에 대해 유한요소해석기법을 이용해서 안전성평가를 수행하였다.

  • PDF

국내 LP 및 천연가스사고 Database 구축 및 분석에 관한 연구 (Constructing a Database Structure for the Domestic LP Gas and Natural Gas Accidents and its Analysis)

  • 고재선;박선영;김효
    • 한국가스학회지
    • /
    • 제12권3호
    • /
    • pp.56-63
    • /
    • 2008
  • 본 연구에서는 1991년부터 최근까지 16년간 발생된 3,593건의 가스사고[천연가스(NG) 및 액화석유가스(LPG)]사례를 수집하여 Database를 구축하였으며, 이를 근거로 사고의 발생건수를 형태 및 원인별로 분석하였다. 분석결과를 살펴보면 사고의 형태로는 누출, 폭발, 그리고 화재의 순서로 많이 발생하였다. 사고발생위치로는 화재는 밸브부위에서, 폭발은 호스부위에서, 그리고 누출은 배관부근에서 가스사고가 많이 발생한 것으로 나타났다. 또한 화재, 폭발, 누출의 각각의 경우에 Poisson 분석법을 적용하여 향후 5년 이내의 화재, 폭발 및 누출에 대한 가장 가능성이 높은 발생확률을 예측하였다. 향후 본 연구에서 구축한 국내가스사고 Database를 매년 지속적으로 보완 개정을 하면 국내 가스사고 예측에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있어 효과적인 가스안전관리 대책수립에 기여할 것으로 기대된다.

  • PDF

HTML5 웹 기반 가연성 물질 누출 피해영향평가 시스템 개발 (A Development of Consequence Analysis System for Combustible Materials Release Events Based on HTML5 Web)

  • 이우귀연;지현민;오정석;조완수
    • 한국가스학회지
    • /
    • 제23권6호
    • /
    • pp.39-60
    • /
    • 2019
  • 한국가스안전공사는 진단 기반기술 국산화와 진단 역량 강화를 위해 자체적인 피해영향평가 시스템을 구축하고 있다. 유사 프로그램인 DNV PHAST나 TNO EFFECTS와 달리, API-581 기준을 근간한 ETA 분석을 통해 최종 피해영역 산출 기법을 구현하였으며, HTML5 기반 차세대 웹 기술을 기반으로 편리한 사용자 인터페이스를 구축하였다. 또한, 혼합물질 분석이 가능하도록 3차 상태방정식(Peng-Robinson, SRK, RK)과 퓨게시티를 활용한 상평형 모듈이 구현되었고, 공기보다 무거운 가스에 대한 확산 분석을 위해 SLAB Dispersion 알고리즘을 적용하였다. CCPS와 TNO Yellow Book에서 소개된 피해영향평가 알고리즘을 채용하여 누출분석 모듈, Fireball, Pool Fire, Jet Fire, Flash Fire, Vapor Cloud Explosion 영향 평가 모듈을 개발하였다. 그 외 EIGA 기준, PAC 기준 농도, Bevi Reference Book 등에서 제시된 기준 값들을 활용하여 안전거리 산출 조건을 마련하였다. 현재 전체 계산 모듈의 알고리즘 구현은 완료되었으며, 기본적인 사용자인터페이스 구축까지 완료되었다. 향후, 사용자 인터페이스 보완과 더불어, 모듈 각각에 대한 개별적인 검증과 동일한 사고 시나리오에 대한 유사 프로그램 구동 결과를 비교하여 전체 시스템의 정확도를 보완할 예정이다.

연소시 생성된 CO가스의 고찰을 통한 인명피해 최소화 방안에 관한 연구 (A Study on the ways to minimize Casualties through a consideration of the CO gas generated during combustion)

  • 최만철;김병석
    • 대한안전경영과학회지
    • /
    • 제15권1호
    • /
    • pp.133-140
    • /
    • 2013
  • Recently developed a variety of architectural interior decoration according hwadoeme type of toxic gases generated during fire also are becoming diversified, resulting in fatal casualties occurred in the trend is also being increased. During a fire, toxic gas that is generated varies depending on the combustible material occurs. However, all combustible materials, including carbon, incomplete combustion of carbon monoxide which is generated in the most common toxic gases can be seen as one. Accordingly, in this study of organic solids that are generated in case of fire toxic gases, and briefly discuss the characteristics of the risks and, by far the most common Co gas for measures to prevent human casualties, seolbijeok, the temperature dependence, divided into four aspects of administrative daechaekdeung explained.