• 제목/요약/키워드: Fire gas

검색결과 1,030건 처리시간 0.023초

동굴 공간의 안전과 방재차단벽 (Embodiment of Firewall Block for Safety in the Cave)

  • 김보수;김강원;김태환;박정호;이영재;소대화
    • 동굴
    • /
    • 제87호
    • /
    • pp.8-13
    • /
    • 2008
  • The automatic firewall block and fire alarm system was embodied by using gas circuit and wireless communication equipment, using a smoke sensor (ST-QA1A) and RF Module. OR-CAD was also used for testing circuit system and experiment circuit after assembling circuit. As a result in experiment, the gas sensor detected well an imaginary smoke and worked reliably for driving action of firewall block motor and wireless warning alarm. Through the smoke sensitive perception from the fire, the warning alarm and the preventing fire propagation from the specific closed region were verified reliably. The gas sensor and RF module for firewall and fire alarm system were actually available.

알루미늄 호일 부착 발포 폴리스티렌 단열재의 열전도율, 열방출시험 및 가스 유해성 시험 (Heat Transfer Coefficient, Heat Release and Gas Hazard Tests for Expanded Polystyrene Heat Insulating Materials with Aluminum Foil)

  • 공하성
    • 대한안전경영과학회지
    • /
    • 제20권4호
    • /
    • pp.15-19
    • /
    • 2018
  • The purpose of this study is to enhance heat insulation effect and to decrease fire hazard by attaching aluminum foil to expanded polystyrene, which is mainly used for insulating materials, to have fire retardant. The result of the test confirmed that the insulating materials, expanded polystyrene of $10kg/m^3$ and $14kg/m^3$ of density attached aluminum foil on both sides, showed 12%, 14% of improved heat transfer coefficient respectively compared to existing expanded polystyrene of the same density. Besides, they met all the standards for the testing of heat release and gas hazard. On the other hand, the one made of general expanded polystyrene could not meet the standards of the heat release test and the gas hazard test.

활성탄 입자 조건에 따른 정화통의 압력손실 특성에 관한 연구 (Pressure Loss in Canisters with Conditions of Activated Carbon Particles)

  • 김민욱;김영수;박용환
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.7-11
    • /
    • 2017
  • 각종 화재, 폭발, 누출, 테러 사고 시 발생되는 유해가스로부터 작업자나 소방대원들의 안전을 확보하고 원활한 구조활동을 위하여 입자형 활성탄을 여과재로 사용하는 특수 방독면의 필요성이 크게 증가하고 있다. 본 연구에서는 CFD 유동해석을 통하여 활성탄 정화통에 대한 압력손실 특성을 규명하였으며, 해석 결과 호흡유량에 대한 압력손실은 유속이 빠를수록, 여과재의 입자가 작을수록, 공극률이 작을수록 커지지만, 특정 조건 이상에서는 그 변화가 매우 크게 나타나 활성탄 여과재의 선택 시 이를 충분히 고려하여야 하는 것으로 분석되었다.

가스사고 통계 및 분석에 관한 고찰 (A Gas Accident Statistics and Analysis)

  • 권혁진;박찬옥;박찬일;여창훈;이장우;홍지룡
    • 한국화재조사학회논문지
    • /
    • 제11권1호
    • /
    • pp.59-65
    • /
    • 2008
  • 각종 화재사고 분류 중 대표적으로 나타나는 가스사고는 그 형태와 원인이 다양하다고 할 수 있다. 가스사용량은 사용가구수가 증가와 사용 장소 및 가스기기의 다양화로 증가하고 있으며, 2007년도 가스사용량은 35,078천톤으로서 연평균 9.4%증가하였다. 가스사고는 95년 557건을 최고로 하여 2007년도에는 123건 발생하여 연평균 11.5%감소되었다. 가스의 종류에 따른 사고건수는 LP가스의 경우 전체 가스사고중 약 80%를 차지하고, 도시가스와 고압가스가 약 20%를 차지하고 있다. LP가 많았고, 특히 공급자부주의에 의한 사고가 끊이지 않고 증가하고 있는 추세이다. 가스사고는 사용자취급부주의, 공급자 취급부주의, 시공불량 및 노후제품으로부터 사고가 발생하여 인명과 재산피해가 발생하고 있다. 본 논문에서는 가스사고의 분류와 형태별, 원인별, 지역별 등에 대한 사고분포를 통해 가스사고의 원인에 대한 이해를 하고 가스안전사고를 예방하는 자료로 활용되도록 하였다.

  • PDF

플레어스택의 화염 형상 분석 (Analysis of Flame Shape in Flare Stack)

  • 이헌석;김범수;정상용;유진환;박철환;고재욱
    • 한국가스학회지
    • /
    • 제13권3호
    • /
    • pp.49-53
    • /
    • 2009
  • 릴리프시스템은 공정 내에 과압 방지하여 공정의 안전성을 높여주는 역할을 한다. 릴리프 시스템에서 방출되는 폐가스로 인한 폭발, 복사열, 독성가스 확산을 막기 위하여 플레어스택을 설치한다. 플레어스택에서는 공정의 안전성 향상을 위하여 안전한 연소가 가장 중요한 요소이며, 안전한 연소를 위하여 방출되는 가스량과 속도 제어는 API 521 code의 기술기준을 따르며, 플레어스택에서 발생하는 화염의 형상은 방출되는 가스의 압력과 질량유속에 의하여 jet fire의 형상을 하고 있다. 이는 화염의 형상은 완전 연소와 열 방출에 영향을 미치는 요소로 이 논문에서는 화염의 형상을 분석하였다. 화염의 길이는 API code와 jet fire 모델이 유사한 값을 보였으며, 화염은 지면에 더 많은 영향을 미치는 것으로 분석되었다.

  • PDF

반도체 및 FPD 분야에 사용되는 $SiH_{4}$ 가스의 공정 안전 고찰 (Review on the Process Safety of $SiH_{4}$ Gas used in Semiconductor and FPD Field)

  • 김중조;김홍
    • 한국안전학회지
    • /
    • 제22권4호
    • /
    • pp.32-36
    • /
    • 2007
  • When the vacuum system for the process of $SiH_{4}$ gas used in the semiconductor and FPD field is partially vented from vacuum to atmospheric state, a fire often occurs due to auto-ignition of $SiH_{4}$ gas. In order to prevent the fire, the concentration of $SiH_{4}$ should be kept under LFL. This means that the higher capacity pump is needed to meet the process conditions as well as the condition that the concentration of $SiH_{4}$ should be kept under LFL. In this article, we conducted the injection of the dilution gas at the manifold between booster pump and dry pump compared with the typical method that the dilution gas was injected into inlet port of booster pump using computer simulation. According to the result, we can flow further more purge gas for safety without any change of the condition in the process chamber, which means that the higher capacity pump is not required for safety in some cases.

LPG 충전소 내 설치된 방호벽의 효용성 평가 (An Availability Assessment of Protection Wall Installed in LPG Filling Station)

  • 이진한;조영도;문종삼;김래현
    • 한국가스학회지
    • /
    • 제22권5호
    • /
    • pp.38-45
    • /
    • 2018
  • LPG충전소 내에서 발생하는 주요 사고는 제트화재, 풀화재, 증기운 폭발로 구분된다. 방호벽을 충전소 내에 설치하면, 제트화재 시나리오에 대해서는 복사열로 인한 피해를 경감할 수 있고 풀화재 시나리오에 대해서는 풀의 확장을 제한하는 효과를 얻을 수 있다. 또한 증기운 폭발 시에는 증기운의 확산과 폭발과압으로 인한 인명피해를 경감하는 효과를 얻을 수 있다. 본 연구에서는 제트화재, 풀화재, 증기운 폭발 등 LPG충전소에서 발생 가능한 사고 시나리오별로 방호벽의 피해경감 정도를 평가할 수 있는 방법을 제안하였으며, LPG충전소 내 방호벽의 효과성에 대해 사례연구를 수행하였다. 이를 통해 제트화재와 증기운 폭발 발생 시 방호벽 뒤에 위치한 수용체의 사망확률을 효과적으로 줄일 수 있다는 것을 보여준다.

불균일 농도 LPG의 폭발 특성에 관한 연구 (A Study on the LPG Explosion Characteristics of Non-uniform Concentration)

  • 오규형
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.111-116
    • /
    • 2003
  • 가로, 세로, 높이가 각각 100cm, 60cm, 45cm로 내용적이 $270\ell$인 폭발 용기를 이용하여 불균일 농도 상태의 LPG-공기 혼합가스의 폭발특성을 측정하였다. 폭발은 vented-explosion과 closed explosion의 조건에서 실시하였다. 실험의 변수로는 점화원의 위치, 노즐직경 및 유속으로, 시료가스를 주입하는 노즐의 직경과 유속을 변화시키면서 용기 내에서의 불균일 혼합정도를 조절하였다. 폭발압력은 strain형 압력센사를 사용하여 측정하였고 폭발화염의 거동은 비디오카메라로 측정하여 분석하였다. 실험결과 유속과 가스 주입 시간이 용기 내 가스 혼합에 중요한 요소임을 알 수 있었으며, 불균일 정도가 심화될 수록 폭발압력과 압력상승속도가 감소하였으나 용기 내 폭발화염의 체류시간은 크게 증가하였으며 이로 인하여 가스 폭발 후 화재로의 전이 위험성이 증가함을 알 수 있었다.

CFD를 활용한 수소-천연가스 혼합연료에 대한 피해영향 분석 (Consequence Analysis of Hydrogen Blended Natural Gas(HCNG) using 3D CFD Simulation)

  • 강승규;방효중;조영도
    • 한국가스학회지
    • /
    • 제17권5호
    • /
    • pp.15-21
    • /
    • 2013
  • 본 연구는 3차원 위험성평가 시뮬레이션 툴(FLACS)을 활용하여 연료의 종류에 따른 위험성을 비교 평가하였다. 일반적인 고압가스 충전소 레이아웃을 활용하여 연료를 CNG, 수소, 30%HCNG로 하였을 경우 충전소에서 가스누출에 의한 화재 폭발 상황을 모사하여 피해영향을 비교 분석하였다. 그리고 가스별 누출제트에 의한 피해영향을 평가하였다. 동일한 조건에서 수소, CNG, HCNG가 누출되어 화재폭발이 발생할 경우 수소는 최대과압이 30kPa, HCNG는 3.5kPa 그리고 CNG는 0.4kPa의 과압이 측정되었다. HCNG의 과압이 CNG에 비해 7.75배 높게 측정되었으나, 수소에 비해서는 11.7%에 불과했다. 화염 전파에 있어서 수소는 매우 빠른 화염전파 특성을 가지는 반면 HCNG와 CNG는 수소에 비해 전파속도 및 전파거리에서 비교적 안전한 경향을 보였다. 제트화염에 의한 화염경계거리는 수소가 5.5m, CNG가 3.4m이고 HCNG는 CNG보다 약간 확장된 3.9m로 예측되었다.

카본제조 부생가스 배출 안전성에 관한 연구 (A Study on the Safety of Carbon Manufacturing By-product Gas Emissions)

  • 주종율;정필훈;김상길;이성은
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.99-106
    • /
    • 2024
  • In the event of an emergency such as facility shutdown during process operation, the by-product gas must be urgently discharged to the vent stack to prevent leakage, fire, and explosion. At this time, the explosion drop value of the released by-product gas is calculated using ISO 10156 formula, which is 27.7 vol%. Therefore, it does not correspond to flammable gas because it is less than 13% of the explosion drop value, which is the standard for flammable gas defined by the Occupational Safety and Health Act, and since the explosion drop value is high, it can be seen that the risk of fire explosion is low even if it is discharged urgently with the vent stock. As a result of calculating the range of explosion hazard sites for hydrogen gas discharged to the Bent Stack according to KS C IEC 60079-10-1, 23 meters were calculated. Since hydrogen is lighter than air, electromechanical devices should not be installed within 23 meters of the upper portion of the Bent Stack, and if it is not possible, an explosion-proof electromechanical device suitable for type 1 of dangerous place should be installed. In addition, the height of the stack should be at least 5 meters so that the diffusion of by-product gas is facilitated in case of emergency discharge, and it should be installed so that there are no obstacles around it.