• 제목/요약/키워드: Fire gas

검색결과 1,030건 처리시간 0.027초

소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안 (Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station)

  • 박제섭;한동훈
    • 한국산업보건학회지
    • /
    • 제30권4호
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

가스계 소화설비의 개구부 보충량 추정에 대한 연구 (A Study on Estimating of Additional Gas for the Unencloseable Openings of The Gaseous Extinguishing Systems)

  • 정기신
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.1-6
    • /
    • 2012
  • 이산화탄소의 소화설비에는 개구부에 대한 소화약제 보충에 대해 구체적인 지침이 있다. 하지만 다른 가스설비, 청정소화약제 설비에는 필요한 경우 적용하라는 원칙 외에 구체적인 조항이 없다. 따라서 이 연구는 이산화탄소의 개구부 약제 추가 공식을 우리가 현제 사용하고 있는 다른 가스계 소화약제에 적용하는 것을 제시하였다.

다중가스센서를 이용한 화재의 조기검출에 대한 연구 (A Study on the Early Fire Detection by Using Multi-Gas Sensor)

  • 조시형;장향원;전진욱;최석임;김선규;강종위;최삼진;박찬원
    • 센서학회지
    • /
    • 제23권5호
    • /
    • pp.342-348
    • /
    • 2014
  • This paper introduced a novel multi-gas sensor detector with simple signal processing algorithm. This device was evaluated by investigating the characteristics of combustible materials using fire-generated smell and smoke. Plural sensors including TGS821, TGS2442, and TGS260X were equipped to detect carbon monoxide, hydrogen gas, and gaseous air contaminants which exist in cigarette smoke, respectively. Signal processing algorithm based on the difference of response times in fire-generated gases was implemented with early and accurately fire detection from multiple gas sensing signals. All fire experiments were performed in a virtual fire chamber. The cigarette, cotton fiber, hair, polyester fiber, nylon fiber, paper, and bread were used as a combustible material. This analyzing software and sensor controlling algorithm were embedded into 8-bit micro-controller. Also the detected multiple gas sensor signals were simultaneously transferred to the personnel computer. The results showed that the air pollution detecting sensor could be used as an efficient sensor for a fire detector which showed high sensitivity in volatile organic compounds. The proposed detecting algorithm may give more information to us compared to the conventional method for determining a threshold value. A fire detecting device with a multi-sensor is likely to be a practical and commercial technology, which can be used for domestic and office environment as well as has a comparatively low cost and high efficiency compared to the conventional device.

가스계 청정소화약제의 소화특성과 첨가제에 따른 영향 (Flame Extinguishing Characteristics of Clean Gaseous Agents and Effects of Additives)

  • 신창섭;김성민
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.95-99
    • /
    • 2008
  • Halon was known as a cause of the ozone layer destruction. In 1987, it was designated as one of the ozone-layer-destroying materials in the Montreal Protocol. Therefore substitutes of Halon agent has been developed including inert gas extinguish system, which is one of the most widely used fire extinguishing system. This study intended to increase the efficiency of inert gas extinguishing agent by using inert gas additives. As IG-541 shows high extinguishing power, the experiment was performed to measure the effects of gaseous additives to it. Cup-burner fire extinguishing apparatus was used with n-Heptane fuel. Among many of pure inert gaseous agents, Helium showed the most excellent extinguishing power. When Helium was added to IG-541, fire extinguishing power was increased and the concentration of oxygen in chimney also risen. By adding Helium to IG-541, the effectiveness of inert gas fire extinguishing system is able to be increased.

인화성액체를 촉진제로 사용한 방화화재의 감식기법에 관한 연구 (Arson Fire Analysis Involving the Use of Flammable Liquilds as Accelerants)

  • 최민기;한동훈;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.64-72
    • /
    • 2014
  • 본 연구에서는 연소잔류물에 남아있는 미세한 인화성액체의 성분을 검출하기 위해 가스검지관, Gas Chromatograph/Mass Spectrometer (GC/MS), 열분해분석장비를 활용하였다. 일반적으로 연소했을 경우와 인화성액체를 첨가하여 연소된 경우의 성분분석결과를 비교하였다. 결과적으로 인화성액체를 첨가하지 않고 연소 후 생성된 화재잔해물에서도 가스검지관이 반응하는 것을 확인할 수 있었다. 일반적인 연소와 열분해를 통해 생성된 화학성분의 차이가 있었으며, 이는 연소 환경의 차이로 인한 것으로 판단된다. 대표적인 석유화학제품인 우드데코타일(PVC) 시료는 인화성액체를 첨가하지 않고 일반적으로 연소시켰을 경우에도 감정인의 정확한 판단을 방해할 수 있는 방해물질인 Toluene, Ethylbenzene, Undecane, Dodecane 등이 검출되는 것을 확인하였다.

[논문철회]화재용 방독면의 CO, HCl, HCN, SO2 연소생성물 제거효율 ([Retracted]Gas Mask Removal Efficiency of CO, HCl, HCN, and SO2 Gas Produced by Fire)

  • 공하성;공예솜;김상헌
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.57-60
    • /
    • 2015
  • 화재 시 발생하는 독성 가스인 CO, HCl, HCN, $SO_2$를 방독면에 의해 제거하는 효율은 화재로 인한 인명구조의 핵심 요소이다. 머리와 목끈이 없는 탄력있는 방독면은 전방을 주시할 수 있는 창, 탄력후드, 가스정화기와 공기 환풍구로 되어 있어서 화재 시 빠르고 쉽게 착용할 수 있다. 이 연구에서는 이러한 방독면의 CO, HCl, HCN, $SO_2$ 제거 효율에 대한 연구를 진행하였다. 실험결과 CO 제거 효율은 최초 농도가 2505.0 ppm인 경우 3.5분 후에 99.99%였고, 8.5분 후에는 99.98%로 나타났다. 8.5분 후에는 CO 농도가 급격히 증가하는 특성을 보였다. HCl, HCN, $SO_2$에 대해서는 최초 농도가 각각 1003.0, 399.0, 100.3 ppm인 경우 20분 동안 제거 효율이 100%로 나타났다.

유류화재의 감식기법의 실험적 특성에 관한 연구 (A Study on Experimental Characteristics in Fire Investigation Techniques of Flammable Liquids)

  • 황태연;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.7-14
    • /
    • 2012
  • 본 연구에서는 화재현장에서 유류와 관련되어 실화나 방화의 매개체로 사용되어 화재가 발생했을 때 석유류의 정확한 분석기법을 개발하기 위하여 발화지점 주변의 온도분포, 연소되고 남은 물질의 흔적과 GC/MS 분석으로 물질의 종류를 확인하는 것을 가연성 고체와 비교해서 실험하였다. 연구결과 천장에 도달하는 온도는 휘발유와 시너는 점화되자마자 불꽃이 생성되어 천장의 온도가 매우 빠르게 상승하여 그곳에 물질이 있을 경우 2차 화재발생이 전개될 것으로 나타났다. 연소된 후에 바닥에는 가연성 고체와 유류가 상이한 특징적인 패턴을 형성하였다. 연소된 장판은 탄화수소계열이지만 가스검지관을 통해 반응을 확인한 결과 가연성 고체는 아무런 반응을 띠지 않았으나 유류는 즉시 반응을 하였고 그 연소물질을 7일이 경과된 후에 GC/MS로 분석한 결과 유류의 존재를 확인할 수 있었다. 화재조사가 복잡한 과정이지만 물질의 특성을 통한 세밀한 조사는 유류화재를 입증하는 데 중요하고 GC/MS분석기기를 통해 실체를 확인하는 과정이 요구된다.

고압 매몰 천연가스 배관 누출사고 피해해석에 관한 연구 (A Study on the Consequences of Underground High Pressure Natural Gas Pipelines)

  • 이승국;신헌용
    • 한국가스학회지
    • /
    • 제17권2호
    • /
    • pp.44-49
    • /
    • 2013
  • 천연가스의 사용량이 날로 증가됨에 따라 고용량의 가스를 운송하기 위해 고압배관의 설치 운영이 불가피하고 이에 따라 고압의 매몰 천연가스배관에서 다양한 원인에 의한 결함 발생 시 대규모 누출로 이어지면 높은 압력의 가스 방출에 따른 대기 중 확산 그리고 점화원에 의한 화재 폭발로 인하여 큰 피해가 발생할 수 있다. 이 연구에서는 고압의 매몰 천연가스배관에서 결함 발생 시 매몰된 배관에서의 가스 누출 거동 분석과 가스 확산 및 지연점화에 따른 플래시 화재의 피해 거리를 예측하여, 사고 영향을 감소할 수 있도록 대피거리의 산정 등에 의한 비상조치계획을 세워 안전관리 활동에 도움이 되고자 한다.