• 제목/요약/키워드: Fire facilities

검색결과 834건 처리시간 0.032초

A Research on the Fire Safety for the Elderly Care Facilities in Japan

  • Kang, Shin-Wook;Ohnishi, Kazuyoshi
    • Architectural research
    • /
    • 제14권3호
    • /
    • pp.85-92
    • /
    • 2012
  • In Japan, there are over the 100's fires in the social welfare organs every years. People are interested in fire protection who live in an institution for the aged or weak person's places and worried about it. I surveyed the social welfare organs were safety from fire to firewarden who worked at an institution for the aged in Tokyo. In the paper, I asked how do you think about the fire safety problems and condition of the facilities. And base on firewarden's view, I reviewed(examined) the fire prevention measures, each facility's problems and how to improve the fire protection.

노인복지시설의 소방안전관리실태에 관한 연구 (Study on the Status of Fire Safety Management in Elderly Welfare Facilities)

  • 고왕열;허만성
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.108-115
    • /
    • 2018
  • 노인복지시설은 입소자들의 신체적, 정신적 능력이 쇠퇴하여 화재 등의 재난시 많은 인명피해가 발생한다. 본 연구에서는 현재 운영되고 있는 노인복지시설의 건축물 구조적 문제, 소방시설의 설치 및 관리에 관한 문제, 소방안전관리자 업무에 관한 문제점 등 소방안전관리실태에 대해 조사, 분석하였다. 최근 대형화재사고 발생 후 관련법령의 개정에 따른 소방시설의 소급적용 등으로 다소 보완되었으나 전반적으로 소방안전관리실태는 아직도 미비한 상태이다. 따라서 관련법령의 추가적인 정비를 통해 건축물 및 소방시설의 안전성과 소방안전관리실태를 개선해나가야 한다.

해양플랜트의 방화대책 및 설계기술 소개 (Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities)

  • 구명준;최재웅;윤호병
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제1권1호
    • /
    • pp.49-57
    • /
    • 2013
  • 해양플랜트의 설계는 위험요인을 정량적 위험성평가를 통해 계량화하여 그 결과를 설계에 반영하는 것이 일반화되어 있다. 대표적인 위험요소인 화재 위험에 대해서도 이는 마찬가지다. 계량화된 화재 위험에 대해 작업자들이 탈출하는 동안 안전설비의 기능을 유지하고 발생된 화재가 더 크게 전이(escalation)되는 것을 방지하는 것이 방화대책의 궁극적인 목적이다. 본 논문에서는 대표적인 방화대책인 능동방화대책과 수동방화대책의 적용사례를 살펴보고 수동방화대책의 설계기법들을 소개한다. 수동방화대책은 효과적인 방화기법이지만 초기 투자비가 많이 소요되고 운용과 유지보수에 애로사항이 크다. 따라서, 최근 들어 발주자들은 수동방화대책을 최적화하도록 해양플랜트 설계자에게 요청하는 추세이다.

방화구획 완화에 따른 PCB공장의 화재위험평가 및 스프링클러 요구살수유량 산정을 통한 기준개선안에 관한 연구 (A Study on a PCB Manufacturing Plant's Fire Risk Assessment due to the Mitigation of Fire Protection Zone and an Improvement Way through Estimation of Sprinkler Demand Water Flow Rate)

  • 오찬욱;오륜석;최준호
    • 한국화재소방학회논문지
    • /
    • 제33권2호
    • /
    • pp.56-62
    • /
    • 2019
  • 스프링클러는 방호구역에 설치된 감지기 또는 헤드가 화재를 감지하여 자동으로 화재를 진압하는 소화설비로 화재 초기에 뛰어난 소화효과가 있어 폭넓게 설치되고 있다. 하지만 국토교통부의 "건축물의 피난 방화구조 기준 등에 관한 규칙"에는 공장 또는 창고의 경우 스프링클러설비를 설치하면 방화구획을 3배까지 완화해 줄 수 있도록 그 근거를 제공하고 있다. 이에 본 연구에서는 스프링클러설비 설치로 방화구획을 완화한 실제 Printed Circuit Board (PCB) 공장 1개소를 대상으로 화재위험성을 분석하였고, 컴퓨터 시뮬레이션을 통한 스프링클러설비의 헤드 개방 특성 및 스프링클러 설비의 설치기준, 감열성능, 작동범위, 방수량 등을 분석하였다. 또한 이를 통해 화재 시 스프링클러 설비 작동의 문제점을 확인하고, 제도 개선을 위한 요구 살수유량 등 근거를 제시하고자 한다.

학교시설물의 노후화 현상 및 지진.화재.풍수해의 피해에 대한 사례 조사연구 (A investigation study on the site analysis damaged by disaster and deterioration reason of school facilities)

  • 윤유혁;신이철;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.21-26
    • /
    • 2008
  • We investigate the various factors such as earthquake, fire, flood and deterioration factors such as carbonation, salt attack, freezing thawing, alkali-aggregate reaction effects on the school facilities. As the consequence of this study we can see that there are very relative relation between deterioration factors and disaster factors. It is the aim of this study to investigate the site analysis damaged by disaster and deterioration factors of school facilities.

  • PDF

화재피해 감소 위한 자동소화장치 적용범위 개선 (Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage)

  • 백창선;박인선
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

설계도서 전수조사를 통한 소방시설분야 성능위주설계 현황조사 (A Survey on the Performance-based Design Status of Fire-fighting Facilities through the Whole Design Drawings and Specifications)

  • 전은구;배영훈;안성호;황철홍;홍원화;최준호
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.155-162
    • /
    • 2019
  • 우리나라에서는 건축물의 화재안전을 확보하기 위해 관련 법령을 개정하여 2011년 이후 대규모 특정소방대상물을 대상으로 성능위주설계를 시행하고 있다. 하지만 아직 우리나라 성능위주설계는 기존의 방식과 비교해보았을 때 화재·피난 시뮬레이션을 통한 인명안전성평가가 추가된 수준에 그치고 있다. 성능위주설계 의무화 이전부터 관련 연구 또한 지속적으로 이루어져 왔으나 주로 행정·제도적 개선방안이나 컴퓨터 시뮬레이션에 치우쳐 소방시설의 설계나 시공 등과 관련된 내용에 대해서는 상대적으로 아쉬움이 큰 것도 사실이다. 이에 본 연구에서는 실제 시행 초기단계인 2016년까지 전국적으로 수행된 91편의 성능위주설계 사전심의도서를 수집하여 소방시설에 대한 성능위주설계 현황을 분석하여 문제점을 도출하였다. 그 결과, 소화설비를 제외한 소방시설들은 성능위주설계가 제대로 이루어지지 않고 있었고, 설계자들은 기존의 법규위주설계에 비해 추가적으로 해당설비를 더 설치하거나 업그레이드된 성능을 가진 상위설비를 설치하면 성능위주설계를 수행하였다는 판단을 하고 있는 것으로 나타났다.

산림화재로부터 문화재를 보호하는 소방시설에 관한 연구 -미분무수설비를 중심으로- (A Study of the Suppression System based on the Fire Protection System the Korea Cultural Property due to the Forest Fire -About Water Mist System-)

  • 공하성
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.44-51
    • /
    • 2007
  • 우리나라 대부분의 문화재인 사찰은 목조 건축물로 가연성이 높고 도심과 떨어진 산속에 있어 화재 진화에도 소방력의 접근성이 용이하지 않아 초기 진화가 어렵다. 또한 장기 지속적인 화원으로부터 문화재 보호를 위한 수원의 확보 및 자체 소방시설도 한계가 있다. 따라서 본 연구에서는 산불로 인한 화재의 초기 진화 및 장기 지속적인 화원으로부터 문화재를 보호하고자 기존의 수계설비보다 피해를 최소화 할 수 있는 미분무수 설비를 적용하여 우리나라 문화재의 지형적 위치를 고려한 가연물의 발화에너지를 제거하는 방식의 소방시설과 차단벽을 활용한 방식의 소방시설을 제안하였다.

Study on Hazard of Toner Cartridge at Recycle Facilities

  • Koseki, Hiroshi;Iwata, Yusaku;Lim, Woo-Sub
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.15-18
    • /
    • 2012
  • Because of development of printing technology, toner cartridge particle becomes smaller and more dangerous. And sometimes we had incidents with dust explosion of toner cartridge particle at recycling facilities in Japan. Therefore we studied on hazard of toner particle relating with dust explosion. We found that toner particle is so dangerous compared with most organic solids, even though it does not belong to hazardous materials in the UN regulation and the Japanese Fire Service Law.

고성산불로 인한 시설물피해특성 연구 (A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun)

  • 염찬호;이시영;박흥석;권춘근
    • 한국재난정보학회 논문집
    • /
    • 제15권4호
    • /
    • pp.469-478
    • /
    • 2019
  • 연구목적: 본 연구는 산불에 의한 시설물피해 특성연구를 위하여 2018년 3월 28일 강원도 고성군 간성읍 탑동리 산16(야산)에서 발생한 산불(피해면적 40ha)을 대상으로 시설물피해 현황을 조사 하였다. 고성산불은 산림 및 농작물 피해는 물론이고, 사람이 거주하는 주택, 공공시설, 창고, 군사시설 등 17건의 시설물에 피해를 주었다. 본 연구의 목적은 이 피해 시설물들의 세부적인 피해원인을 분석하여, 산림인접 시설물들에 대한 산불피해 방지 방안을 제시하기 위하여 수행하였다. 연구방법: 고성산불발생시 기상을 분석하기 위해 산불발생과 진화완료시(2018.3.28 06:19 ~ 22:00)의 기상상황(기온, 풍속, 풍향, 습도)을 1분단위로 분석하였고, 시설물 피해 사례조사를 위해 고성산불로 인해 발생한 17건의 시설물 중 군사시설 등을 제외한 10건의 피해 시설물 주변의 경사도, 사면향, 지세특성, 산림과의 이격거리, 주요수종, 수관화발생 유무, 주택방위, 주택재질 등 9개 항목에 대한 현장조사를 실시하여 산불피해특성을 분석하였다. 연구결과:고성산불 발생과 진화완료시(2018.3.28 06:19 ~ 22:00)의 기상상황(간성 517AWS)은 기온 및 습도가 고온 건조한 상태였으며, 풍속은 평균 4.1m/s, 최대 11.6m/s의 강한 바람이 불었다. 주풍향은 W(225~315°)방향이었으며, 산불의 확산 방향과 일치하였다. 또한 산불피해 시설물들은 급경사지와 능선의 산정부에 위치하였고, 시설물주변 산림은 수관화 발생지역의 소나무 밀임분 지역이었다. 산림과 시설물과의 이격거리는 평균 13.5m이었으며, 시설물의 재질이 불에 강한 콘크리트였을 경우 경미한 피해를 입었지만, 샌드위치판넬 등 산불에 약한 재질은 모두 전소한 것으로 나타났다. 결론: 본 연구를 통해 얻은 결과인 주택주변의 숲 가꾸기 실시와 이격거리 확보, 시설물들의 불연재 재질로의 개선 등을 통해 산림인접 시설물들에 대한 산불방지 대책수립에 기여 할 것으로 기대된다.