• Title/Summary/Keyword: Fire extinguishing test

Search Result 92, Processing Time 0.018 seconds

A Study on the Confirmation of non-flammabikity of the Cast Resin Mold Transformer in Subway Substation (지하철 변전실용 진공주형형 몰드변압기의 난연성 확인에 관한 연구)

  • 정용기;장성규;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 1998
  • This dissertationhas confirmed the non-flam mability of cast mold transformer that is increasingly used lately. As a research progress, the investigation has been performed on the installation status and each line of the subway system which have the most mold transformer accidents, and the impediment status of the transformer for rectifier and the high-voltage distribution transformer per each manufacturer. Then, a high voltage mold of the actual mold transformer has been installed in the horiwntal heating furnace and the heat has been applied by the standard heating temperature curve of KSF 2257(Fireproof testing meth od of the construction structures: 1993). Accordingly, the combustibility of the mold transformer based on the test results has been found that 78 minutes has been required for the complete burning per the KSF 2257 combustion test curve and that, after stopping the heat application of the horizontal furnace after ignition, the flame progress has not been made but shown as the self-extinguishing characteristics when the flame progress has been checked. Thus, the non-flammability and self-extinguishability of the mold transformer have been confirmed. The result of this dissertation has indicated that the accident involving mold transformer has been progressed and expanded by the dielectric breakdown or void due to the crack in the mold rather than a fire accident caused by a short-circuit or an overload.r an overload.

  • PDF

Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity (단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발)

  • Joo, Nam-Kyu;Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.360-366
    • /
    • 2012
  • In the power distribution panel installed in airport or industrial facilities, MCCB has been used for main switch and ELCB for branch switch to perform human body and leakage-inducing fire protection as well as overcurrent and short circuit protection. Especially for the airport panel, increase in accident protection is needed for stable power supply due to rapid modernization with fast-growing users, higer capacity and diversification of equipment, the increase of power capacity and the breaker made slim is a main issue for now because the issue for installation space is standing out by making panel with two-row arrangement connection method, etc. due to a many use of branch ELCBs. In this thesis, we designed arc extinguishing mechanism, considered movement direction change of contact in mechanism design. Also, we designed the breaker to work stably in case of miniaturization of leakage detection circuit and reverse connection. We conducted short circuit test to verify its function and developed the breaker that can be improved protection against accidental current with slim size operating leakage function when reverse connection to help solve the problem in using space that is increasing in the airport distribution panel.