• 제목/요약/키워드: Fire extinguishing systems

검색결과 81건 처리시간 0.023초

STEPS TOWARD HALON PHASE-OUT, PROPOSED SUBSTITUTES AND ALTERNATIVE FOR FIXED FIRE SUPPRESSION SYSTEMS

  • Msc.Fpe, Suprapto;Rahardja, Nugraha-B
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.564-572
    • /
    • 1997
  • Following the ratification of Vienna Convention for Ozone Layer Protection and Montreal Protocol, Indonesia will implement the phasing-out of to halon at end 1996. Questions are increasing especially from the users where halon has used for many years as the most effective fire extinguishing agent, concerning halon substitutes, alternative systems as well as the handling and utilization of the existing halon. Halon can still be used for critical and essential uses, however, such usage has been gradually eliminated, due to the emergence of halon-like replacement. A concept of halon banking system is proposed to considered, taking into account several aspects such as enforced regulation, institutional involvement technology as well as financing. This paper gives a general overview regarding phase-out implementation, alternative extinguishing systems and concept on halon banking system with special reference to Indonesian case.

  • PDF

Recent Progress in Methods of Generating Water Mist for Fire Suppression

  • Guangxuan, Liao;Xin, Huang;Beihua, Cong;Jun, Qin;Jianghong, Liu;Xishi, Wang
    • 한국분무공학회지
    • /
    • 제11권4호
    • /
    • pp.251-265
    • /
    • 2006
  • To prevent the ozonosphere from being destroyed by Halon, it is an urgent task to find out Halon replacement. As one of the replacements water mist have showed broad applications by its advantages: little pollution to environment (not destroying the ozone layer or bring green house effect), extinguishing fire quickly, consuming a small quantity of water and having little damage to the protected objects. The methods of generating water mist strongly influence fire suppression effectiveness, which determine the cone angle, drop size distribution, flux uniformity, and momentum of the generating spray. The traditional water mist nozzle included pressure jet nozzles, impingement nozzles and twin-fluid nozzles. All of them have more or less disadvantages for fire suppression. Therefore, many research institutes and corporations are taking up with innovations in mist generation. This article provided some recent studies in State Key Laboratory of Fire Science (SKLFS) of University of Science and Technology of China. SKLFS have investigated new methods of generating water mist (i.e. effervescent atomization and ultrasonic atomization). and self developed a series of nozzles and developed advanced DPIVS (Digital Particle Image Velocimetry and Sizing) technique. Characteristics of water mist (the distribution of droplet sizes, flux density, spray dynamics and cone angle) produced by these nozzles were measured under different conditions (work pressure, nozzle geometry, etc.) using LDV/APV and DPTVS systems. A series of experiments were performed to study the fire suppression effectiveness in different fire scenario (different kindsof the fuel, fire size and ventilation conditions). The fire extinguishing mechanisms of water mist was also discussed.

  • PDF

압축공기포(Compressed Air Foam) 소화시스템을 이용한 구난역 열차 화재 진압에 관한 실험적 연구 (Experimental study on the suppression of fire fighting by using Compressed Air Foam system)

  • 박병직;신현준;유용호;박진욱;김휘성;김양균
    • 한국터널지하공간학회 논문집
    • /
    • 제20권2호
    • /
    • pp.423-432
    • /
    • 2018
  • 대구지하철 화재사고가 발생한 이후에 국민의 안전에 대한 관심이 높아지고 열차 내부의 재료는 불연성 재질로 모두 변경되었지만 소화 설비에 관한 개발은 미비한 상태이다. 열차는 철판 재질로 둘러싸여 화재 시 일반적인 소화설비를 이용하면 소화하기 매우 어렵다. 본 논문은 실물화재 실험을 통하여 정차된 열차 화재를 압축공기포 소화설비를 활용하여 빠르고 손쉽게 소화할 수 있는 방안에 대하여 연구하였다. 구난역에 정차된 열차의 화재를 소화하기 위해서 창문 파괴장치를 이용하여 열차 유리창을 빠르게 파괴하고 압축공기포 소화설비를 열차 내부에 삽입하여 직접적으로 소화할 수 있도록 하였다. 창문 파괴장치를 이용하여 열차 유리창을 5초 만에 파괴하였으며, 압축공기포 소화설비를 열차 내부에 삽입하고 압축공기포를 방사하여 30초 만에 열방출량 11.88 MW 규모 화재를 진압하였다. 압축공기포 소화설비를 이용하여 화재 확산 방지와 터널 구조물 보호가 가능하도록 추가적인 실험 연구가 필요하다.

질식사고 방지용 CO2 소화설비의 선박 적용성 (Applicability of CO2 Extinguishing System for Ships)

  • 하연철;서정관
    • 대한조선학회논문집
    • /
    • 제54권4호
    • /
    • pp.294-300
    • /
    • 2017
  • The offshore installations and ships are the structures most likely to be exposed to hazards such as hydrocarbon fire and/or explosion. Developing proactive measures to prevent the escalation of such events thus requires detailed knowledge of the related phenomena and their consequences. $CO_2$ extinguishing systems are extensively used for fire accidents of on-and offshore installations because of outstanding performance and low cost. There is, however, the risk of carbon dioxide system which enumerates many of the fatalities by suffocation associated with industrial fire protection requirements. Therefore, the aim of this study is to perform the prediction of fire suppression characteristics of the carbon dioxide system in realistic enclosed compartment area of ships and propose $CO_2$ extinguish fire fighting system for preventing suffocation accidents during fire fighting. According to CFD calculations, it can be observed and assessed that various fire profiles with $CO_2$ and $O_2$ mole fraction in the target enclosed compartment area are applicable within the proposed system. Additionally, the design of fire safety system of ships and offshore installations can utilize ventilation system and/or layout arrangement through the proposed system.

소화약제 누기 감시장치의 모듈개발 및 성능검증에 관한 연구 (A Study on the Development of a Fire Extinguishing Agent Leakage Monitoring Module and its Performance Assessment)

  • 손봉세;홍성호;고아라
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.43-48
    • /
    • 2016
  • 가스계소화설비는 소화약제의 자연 누기와 소화설비 노후로 인한 누기 등으로 화재진압 능력이 저하되는 문제점이 발생하고 있다. 이에 본 연구에서는 소화약제의 누기를 실시간으로 감지하는 압력누기 체크센서 모듈을 개발하였으며, 개발 모듈에 대한 성능평가를 하였다. 국내 외적으로 압력누기 감시 시스템에 대한 명확한 시험기준이 마련되어 있지 않다. 따라서 국외 유사 기준 ISO 7240, FM 1421와 국내 수신기 형식승인 및 제품검사의 기술기준을 참고하여 개발 모듈에 맞게 기본 성능과 내환경성에 대한 기준을 마련하고 평가를 실행하였다. 기본 성능 평가는 압축공기를 모듈에 인가하는 방식으로 최저작동 압력이 0.3 bar인 것을 확인하였다. 내환경성 검증은 통상적으로 발생할 수 있는 기후변화에도 오작동 없이 정상적으로 작동하는지를 확인하였다. 그 결과, 고온($50^{\circ}C$) 및 저온($-10^{\circ}C$) 환경 기준에서 이상 없이 정상 작동하였다.

항공기 엔진베이 내 소화장치 성능예측을 위한 연구 (A Study on the Performance Prediction of Fire Extinguish System in Aircraft Engine Bay)

  • 박영하;김형식;김진환;조수용
    • 한국항공우주학회지
    • /
    • 제40권8호
    • /
    • pp.718-725
    • /
    • 2012
  • 항공기 엔진베이에 누유된 연료나 오일이 고온의 엔진 표면에 닿게 되면 점화되어 화재를 야기시킬 위험성이 높다. 이를 방지하기 위하여서는 소화제를 화재방지영역에 신속하게 분사하고 소화제의 농도가 높이 유지되도록 화재방지시스템을 설계하여야 한다. FAA에서는 소화제가 화재방지영역 전체에 6%의 농도를 0.5초 이상 유지하는 것으로 규정하고 있다. 이러한 요구를 만족할 수 있는 화재감지시스템의 개발을 위하여, 본 연구에서는 엔진베이에 소화제의 분사와 농도측정에 대한 수치적인 연구와 실험적인 연구를 수행하였다. 분사된 소화제의 분사시간이나 농도유지에 대하여 실험과 수치적인 연구의 결과는 유사한 경향을 보이나, 실험에서 센서의 응답성으로 인하여 소화제의 농도가 늦게 측정되었다.

실내 화재 진압 및 인명구조 기술 개발 (Development of Eire Extinguishment and Life-saving Technology for Indoor Environment)

  • 오주환;최재석;이우준
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.108-113
    • /
    • 2007
  • The robot introduced in this paper is the Fire-Extinguishing Rescue Robot for indoor work which is considered to be a part of the Operation for Future Developmental Power. It is briefly introduced about the background of how we began this project, our goals, where we are today and what we would like to achieve from now on. Main contents include introduction to the equipments for Fire-Extinguishing Rescue robots that have been developed in advanced countries and the compositional concept of the developmental process, the GUI schematic, searching methods for fire inside a house, mechanical schematic and the present conditions of how the core technologies are developing through.

선박용 미분무수 소화설비의 성능평가연구 (A Study on the performance test of Water mist system as a fire extinguish system for Ships)

  • 김성윤;안병호;김동석;김유택
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.155-156
    • /
    • 2006
  • Developed and conducted a performance test of the Water mist system that is satisfied with the requirement of a fire test requiring Class 3 Engine Mock-up exceeding net volume $3,000m^3$ as per IMO's MSC/Circ. 668 Appendix B(Test method for fire testing equivalent water-based fire-extinguishing systems for machinery spaces of category A and cargo pump rooms).Even though fuel atomizing was continued for 15 sec. after stopping of the system according to the test method relating to the atomizing fire type, no fire was reignited. This result shows the excellence of the system. There was no damage to the contents of the system after the test.

  • PDF

압축공기포 소화설비의 소화성능 평가에 관한 연구 (A Study on Fire Extinguishing Performance Evaluation of Compressed Air Foam System)

  • 이장원;임우섭;김성수;이동호
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.73-78
    • /
    • 2012
  • 본 연구는 압축공기포 소화설비의 소화성능을 평가하기 위해 포헤드 설비를 이용하여 실험을 진행 하였다. 압축공기포 소화설비는 포수용액에 압축공기를 혼입하여 포를 발생시키는 방식으로 해외에서는 원거리 방수가 가능하고 물 사용량을 줄여 수손피해를 최소화할 수 있는 압축공기포 소화설비(CAFS: Compressed Air Foam System)가 많이 활용되고 있다. 본 연구에서는 UL162 기준으로 수성막포 3 % 포 소화약제를 적용하여 기존의 공기 혼입 방식에 의한 포 소화설비와 압축공기포 소화설비간 비교 실험을 통하여 소화 성능 효과를 비교 분석하였다. 압축공기포 소화설비의 공기 혼입 비율은 포 수용액과 1 : 1의 부피 비율로 하였으며 발포유량은 각각 140 L/min, 160 L/min, 180 L/min, 200 L/min으로 변화를 주면서 소화효과를 검증하였다. 그 결과 소화 성능면에서는 압축공기포 소화설비가 공기 혼입 방식보다 모든 유량 조건에서 소화시간이 빠르게 나타났다.