An Experimental Study on the Fire Hazards in Electric Heater (전기히터의 화재위험성에 관한 실험연구)

  • Hong, Sung-Ho;Lee, Bock-Young;Park, Sang-Tae;Yu, Hyun-Jong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.2 s.80
    • /
    • pp.36-40
    • /
    • 2007
  • This study presents on the analysis fire hazards of electric heater. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition. The abnormal condition experiment is simulated in which combustibles are placed near by electric heater. Vertical burning test(UL 94) is conducted for the fire retardant experiment. The results show that fire hazard is high in case of abnormal condition. And Material of electric heater has not fire retardant performance. In this paper, we suggest to add temperature fuse in electric heater for reducing fire hazard.

A Experimental Study on the Fire Safety of Drum-type Electric Washing Machine (드럼세탁기 화재안전성 확보를 위한 실험연구)

  • Hong, Sung-Ho;Lee, Sang-Hyun;Park, Sang-Tae;Yu, Hyun-Jong;Jeon, Woong-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.131-133
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

  • PDF

ANALYSIS OF FIRE CHARACTERISTICS IN APARTMENT BUILDING THROUGH FULL SCALE EXPERIMENT AND ZONE MODEL SIMULATION

  • Yoon, Myong-O;Park, Jin-Kook;Kim, Choong-Ik;Ryou, Hong-Sun;Kim, Jin-Gon;Kim, Myung-Bae;Choi, Jun-Seok;Kim, Kwang-Il
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.413-422
    • /
    • 1997
  • Fire characteristics of a typical apartment building in Korea was studied through full scale experiment and zone model simulation. The fire was ignited at the living room and allowed to spread to other parts of a single unit in a five storied apartment building. Various data including temperatures, species concentrations, and images were collected in the experiment. A zone model(CFAST) was used to analyze the same apartment building that represents the average households in Korea. The results were compared with a full scale experiments. While CFAST allows one compartment involved with fire, the experiment allowed the fire to spread to other compartments. Therefore, the comparison between experimental data and Zone-Model data is valid until the living-room fire spread to other parts of the apartment. Flashover occurred at approximately 380 seconds in a fire experiment, and at approximately 420 seconds in Zone-Model. Based on all of data between experimental data and Zone-Model data, it is concluded that the safe escape time is about 250 seconds.

  • PDF

Forest fire experiment toward the detection of forest fires using RS - Thermal and reflectance environment change observation at ground level -

  • Tanpipat, Veerachai;Honda, Kiyoshi
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.690-695
    • /
    • 2002
  • In this forest fire experiment the ThermoViewer was set up on the platform built on a tree and observed the temperature change, before, during and after the fire. The fire experiment had been carried out not only the day of the forest fire experiment but also continued for four months after the forest fire had been gone. The results from the experiment showed that the temperature difference is significant in the afternoon; therefore, afternoon satellite passing is better and suitable time for active forest fires and burnt scars detection; moreover, after 83 days, the burnt and un-burnt vegetation become almost the same condition, fully regenerated and the temperature difference become nearly 0$^{\circ}$ Celsius, so there is not enough temperature different between burnt and un-burnt vegetation for current sensors to distinguish the difference anymore.

  • PDF

An Experimental Study on the Fire Hazard of Electric Heating Pad (전기장판의 화재위험성 실험연구)

  • Lee, Bok-Young;Park, Chan-Ho;Park, Sang-Tae;Hong, Sung-Ho;Yu, Hyun-Jong
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.113-117
    • /
    • 2006
  • This study presents analysis of fire hazard of electrical heating pad. In order to analyze fire hazard fire experimental and flammability experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition such as breakdown of thermostat. Vertical burning test(UL 94) is conducted for the fire retardant experiment. Kinds of electric heating pad used for experiment are electric mat, fabric pad, vinyl pad. The results show that fire hazard is high in case of breakdown of thermostat with the rating voltage supply. And Material of electric heating pad has not fire retardant performance.

A Experimental Study on the Fire Hazards in Drum-Type Electric Washing Machine (건조일체형 드럼세탁기의 화재위험성에 관한 실험연구)

  • Hong, Sung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.328-331
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

Fire Suppression Experiment for Road Tunnel Low Pressure Water Spray Systems (도로터널 저압 물분무설비 화재진압 실험)

  • Choi, Byung-Il;Han, Yong-Shik;Kim, Myung-Bae;So, Soo-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.218-221
    • /
    • 2008
  • The real scale fire suppression test inside a road tunnel were carried out for water spray systems. The dimension of the tunnel is 7.5m in height and 11.6m in width. 3 different water spray nozzle systems with low operating pressure less than 3.5 bar were used in the experiment. Two types of fires were tested. One is a $1.4m^2$ heptane pool fire and the other is a 2000CC passenger car fire. From the experiment, the spray densities of tested systems were about $6.0\;l/min/m^2$ which is currunt domestic guideline. Although all the systems cannot extinguish the tested fires, it was found that they can reduce the tunnel temperature and have a capability to control and suppress the tested fire.

  • PDF

An Intelligent Fire Detection Algorithm for Fire Detector

  • Hong, Sung-Ho;Choi, Moon-Su
    • International Journal of Safety
    • /
    • v.11 no.1
    • /
    • pp.6-10
    • /
    • 2012
  • This paper presents a study on the analysis for reducing the number of false alarms in fire detection system. In order to intelligent algorithm fuzzy logic is adopted in developing fire detection system to reduce false alarm. The intelligent fire detection algorithm compared and analyzed the fire and non-fire signatures measured in circuits simulating flame fire and smoldering fire. The algorithm has input variables obtained by fire experiment with K-type thermocouple and optical smoke sensor. Also triangular membership function is used for inference rules. And the antecedent part of inference rules consists of temperature and smoke density, and the consequent part consists of fire probability. A fire-experiment is conducted with paper, plastic, and n-heptane to simulate actual fire situation. The results show that the intelligent fire detection algorithm suggested in this study can more effectively discriminate signatures between fire and similar fire.

Validity Analysis of Scale Model Experiment for Wetting Agent Performance Evaluation (침윤소화약제 성능평가를 위한 축소실험의 타당성 분석)

  • Kim, Nam-Kyun;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.14-19
    • /
    • 2014
  • A current standard exist only on the surface tension in the current domestic wetting agent technology standards, so it is difficult to the performance evaluation of the wetting agent through the standard. So this study presents the optimized performance evaluation methods by scale model experimental equipment in order to present techniques for performance evaluation of wetting agents. The purpose of this study is to investigate validity of experimental results of the self-designed scale model experiment equipment by a comparative analysis of experimental results of the NFPA 18 experiment and the experiment using the self-designed scale model experiment equipment. As a result of a comparative analysis of experimental results of the NFPA 18 experiment that evaluate only the permeation performance on the contton and the experiment using the self-designed scale model experiment equipment that evaluate the permeation performance and fire extinguishing performance on wood flour, the discrimination of the permeation performance was confirmed in both the NFPA 18 experiment and the self-designed scale model experiment equipment. And a result of self-designed experiment equipment have clear discriminatory more than NFPA 18 by internal temperature measurement using the thermocouples.

화재감지기의 경년도에 상관한 감응특성 실험.연구

  • Lee, Bok-Yeong;Yu, In-Ho
    • Fire Protection Technology
    • /
    • s.16
    • /
    • pp.13-19
    • /
    • 1994
  • An Experimental study on the relation between responsiveness and elapse of years This experiment study is to appraise a fire detector's durability & reliability. Fire detector is located in office, temp range 10-27 고 65 15%, installed in the ceiling with power on. This is the experiment report of elapsed 5 years.

  • PDF