• Title/Summary/Keyword: Fire escape

Search Result 233, Processing Time 0.024 seconds

A Study on Design Improvement for Smoke-Control System Using the Pressurization of the Elevator Shaft (승강로 가압 제연설비의 설계개선에 관한 연구)

  • Kim, Il-Young;Kim, Kyung-Jin;Hong, Ji-Hwan;Kwon, Chang-Hee;Yoo, Chul-Kwon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.74-83
    • /
    • 2019
  • In the U.S., the pressurization of elevator shaft was developed in 1972 to allow vulnerable people, such as the elderly and weak who could not use escape stairs in case of fire, to evacuate. It is an advantage in terms of space saving by not using vertical ducts. This study drew the problem of the pressurization of elevator shaft based on the existing domestic patents and proposed improvements. The smoke control volume calculation method is proposed by using vertical modeling. Leakage gaps in elevator doors need to be reviewed through experimental data or actual data. The evacuation floor was divided, the openings in the elevator machine room were automatically closed to the fire signal and the relief damper was installed to improve the performance. The improved method functions as the smoke control damper supplying the air flow rather than maintaining the differential pressure. To increase reliability of the research results, the procedure was performed to verify by using Contam.

Combustional Characteristics of Living Leaves for Five Shrubs in Youngdong Areas (영동지역 관목류 5가지 수종 생엽의 연소특성)

  • Lee, Hae-Pyeong;Lee, Si-Young;Park, Young-Ju
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.81-87
    • /
    • 2009
  • In this study, we have investigated the combustibility of five shrubs growing in Youngdong area such as Lindera obtusiloba, Lespedeza maximowiczii, Zanthoxylum piperitum, Zanthoxylum schinifolium, and Corylus heterophylla var. thunbergii using the ignition temperature tester, the cone calorimeter and the smoke density chamber in order to estimate the danger of a forest fire. The results showed that Lespedeza maximowiczii has the lowest ignition temperature, the fastest ignition time and the highest average release concentrations of CO and $CO_2$. Zanthoxylum piperitum and Zanthoxylum schinifolium showed the highest level in heat release and smoke release, respectively. Therefore, we have concluded that Lespedeza maximowiczii has the highest ignitibility, Zanthoxylum piperitum the most intensive fire spread and fire intensity, and Zanthoxylum schinifolium and Lespedeza maximowiczii most difficult to escape from a forest fire.

A Study on the Architectural Planning of the Refuge Areas in Geriatric Hospitals Considering Horizontal Evacuation of the Elderly (노인요양병원에서 고령자의 수평 피난을 고려한 대피공간의 건축계획에 관한 연구)

  • Kim, Mijung;Kweon, Jihoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.3
    • /
    • pp.7-15
    • /
    • 2023
  • Purpose: This study was conducted with the aim of presenting spatial planning directions for evacuation spaces based on an analysis of the performance of horizontal evacuation during the early stages of fire incidents in a geriatric hospital. Methods: Based on a review of previous studies, the research model was designed by establishing occupancy conditions, evacuation, and fire scenarios. The analysis model was developed by considering vulnerable areas in terms of evacuation movement and analyzing the results of evacuation performance. Furthermore, the study analyzed the improvement in evacuation performance by arranging refuge areas. Results: The results of the study are as follows. Firstly, vulnerability spots were identified in terms of evacuation performance by schematizing Required Safe Egress Time, Available Safe Egress Time, and their differences. Secondly, the Required Safe Egress Time in the adjacent public spaces along the escape routes of occupants was found to be higher compared to the Available Safe Egress Time. Thirdly, the results of the correlation analysis between the difference in Available Safe Egress Time and Required Safe Egress Time during the early stages of a fire, as well as their constituent factors, demonstrated that user congestion is a more significant factor in compromising evacuation safety than the physical changes in the fire condition. Fourthly, the analysis of evacuation time was conducted by designating refuge areas where occupants can evacuate within a sufficient timeframe. This led to a decrease in the Required Safe Egress Time. Implications: This study is expected to be used as data on the direction of evacuation space planning to improve the evacuation performance of Geriatric Hospital.

Escape Route Prediction and Tracking System using Artificial Intelligence (인공지능을 활용한 도주경로 예측 및 추적 시스템)

  • Yang, Bum-suk;Park, Dea-woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.225-227
    • /
    • 2022
  • Now In Seoul, about 75,000 CCTVs are installed in 25 district offices. Each ward office in Seoul has built a control center for CCTV control and is building information such as people, vehicle types, license plate recognition and color classification into big data through 24-hour artificial intelligence intelligent image analysis. Seoul Metropolitan Government has signed MOUs with the Ministry of Land, Infrastructure and Transport, the National Police Agency, the Fire Service, the Ministry of Justice, and the military base to enable rapid response to emergency/emergency situations. In other words, we are building a smart city that is safe and can prevent disasters by providing CCTV images of each ward office. In this paper, the CCTV image is designed to extract the characteristics of the vehicle and personnel when an incident occurs through artificial intelligence, and based on this, predict the escape route and enable continuous tracking. It is designed so that the AI automatically selects and displays the CCTV image of the route. It is designed to expand the smart city integration platform by providing image information and extracted information to the adjacent ward office when the escape route of a person or vehicle related to an incident is expected to an area other than the relevant jurisdiction. This paper will contribute as basic data to the development of smart city integrated platform research.

  • PDF

Prototype Implementation of a Personalized Warning Notification System based on Geosocial Information (지오소셜 정보 기반 개인 맞춤형 경보 시스템 원형 구현)

  • Tiep, Vu Duc;Quyet, Nguyen Van;Kim, Kyungbaek
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.332-334
    • /
    • 2015
  • Nowadays a disaster event such as a building on fire, an earthquake or typhoon could occur any time, and any where. In such event, a warning notification system is a vital tool to send warning notifications to at-risk people in advance and provide them useful information to escape the dangerous area. Though some systems have been proposed such as emergency alert system using android, SMS or P2P overlay network, these works mainly focus on a reliable message distribution methods. In this work, we introduce a full prototype implementation of a personalized warning notification system based on geosocial information, which generates a personalized warning message for each user and delivers the messages through email or an android application. The system consists of four main modules: a web interface, database, a knowledge-based message generator, and message distributor. An android application is also created for user to receive warning messages on their smart phone. The prototype has been demonstrated successfully with a building-on-fire scenario.

Analysis of Change of Event Related Potential in Escape Test using Virtual Reality Technology

  • Hyun, Kyung-Yae;Lee, Gil-Hyun
    • Biomedical Science Letters
    • /
    • v.25 no.2
    • /
    • pp.139-148
    • /
    • 2019
  • The role of electroencephalography (EEG) in the development of brain-computer interface (BCI) technology is increasing. In particular, the importance of the analysis of event related potential (ERP) in various situations is becoming more significant in BCI technology. Studies on past maze and fire situations have been difficult due to risks and realistic problems. Nowadays, according to the development of virtual reality (VR) technology, realistic maze and fire situation can be realized. In this study, ERPs (P300, and evented related negativity) were analyzed to collect objective data on case determination in an emergency situation. In order to overcome the limitations of previous methods that evaluating the EEG frequency change, ERPs were derived by setting epochs for stimulation and standardizing them, and evaluated for ERPs in this study. P3a and P3b, which are subcomponents of P300, were analyzed and the evented related negativity (ERN) was analyzed together with error positivity (Pe). As a result of the study, statistically significant changes of ERPs were observed, this result, which has little related research, is considered to be meaningful as medical basic statistics.

A Study on the Effects of an Increase in the Height of Ship's Accommodation Area on Safe Evacuation in Emergency Situation (선박 거주구역의 높이가 피난안전에 미치는 영향에 대한 연구)

  • Kim, Won-Ouk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.1
    • /
    • pp.69-73
    • /
    • 2011
  • Unlike land fires, Fires on board a ship are not likely to be extinguished by skilled human resources using a variety of fire fighting equipments, but have to be brought under control on board a ship itself despite of difficult task. There are more cases of deaths from suffocation by smoke than from an increased temperature by heat in fires on board ships, because crew fail to secure a sufficient visibility range enough to escape from the scene of a fire or to leave the ship as early as possible. On the assumption that the height of ship's accommodation area increases from 2.0m to 2.3m comparable to the height of apartments on the ground in Korea, behaviors of fire smokes between the cases of 2.0m and 2.3m heights were compared and analyzed. Based on the blue print of the existing Training Ship "Hanbada", a new blueprint with the 30 cm height adjustment was additionally created. FDS (Fire Dynamic Simulator), which was created by the NIST in the United States and is the most widely distributed simulator for fires, was used to conduct a simulation and predict results. The results of simulation on the basis of temperature of $60^{\circ}C$ showed a safe evacuation period of time at the position 10m apart from the scene of a fire to increase by 55.8 seconds, when the height of ship's accommodation area increased from 2.0m to 2.3m. The results of simulation on the basis of visibility range of 6m showed the safe evacuation periods of time at the positions 10m, 20m and 30m apart from the scene of a fire to increase by 27.1 seconds, 109.2 seconds and 73.3 seconds, respectively, as the height of ship's accommodation area increased from 2.0m to 2.3m. This means that crew can escape more safely from a scene of fires on board when the height of ship's accommodation area is increased and equal to the height of living room in a building on land.

A survey of the Types of Burns in Children and Mother's Preventive Attitudes to, and Knowledge of Burns (어린이 화상사고 유형과 어머니의 예방, 태도, 지식에 대한 실태조사)

  • Han Jung Suk;Kim Dong Hee
    • Child Health Nursing Research
    • /
    • v.4 no.1
    • /
    • pp.97-104
    • /
    • 1998
  • Burns in children result in the loss of precious life, or if the child survives, in much suffering from physical, emotional, social, and economic problems. These burn accidents to children happen in the bustle of family life and frequently without any warning. With this background information, this study was designed to identity types of burns in children and mothers' attitudes towards, and knowledge of burn prevention, in order, to not only, in still a safety consciousness regarding the seriousness of burn accidents and the strengthening prevention, but also as basic data towards the development of an educational program aimed at prevention. From May 1 to May 25 in 1997, data were collected from the mothers of children attending five day care centers and kindergartens located in Seoul, which had been selected for the study. The tools used for the study, which were developed by the researchers, surveyed the type of burns suffered by children, mothers' knowledge of burns and attitudes toward burn accidents. The data were analyzed through real numbers percentages and analysis was done using SPSS computer programs. The results of the study show that the most frequent type of burn accidents were those caused by hot water(55.4%) and these were frequently related to everyday habits that easily lead to danger. Further, the first aid treatment following a burn was weak. The majority of the mothers had not instructed their children on who to contact in the case of a fire, first aid for burns, or how to take escape in the case of a fire. This left the children in a defenseless position in case of a fire. The mothers showed a lack knowledge, on what to do when a blaze is discovered, how to put out a fire, first aid for burns, escaping from a fire and appropriate water temperature, in that 50% of the time they answered incorrectly. From this study a prevention program, HIPP (Home Injury Prevention Program) could be developed that includes fire prevention habits and first aid for burns. This program can be used with kindergarten and elementary school children for group education on fire prevention and can be used as a foundation for construction of a system of facilities and equipment to prevent fires and also prevent injury from fires.

  • PDF

Experimental Study on the Designed Ventilation System Performance at Rescue Station in Tunnel Fire (터널 내 화재발생시 구난역 내의 설계된 환기 시스템 성능에 대한 실험적 연구)

  • Kim, Dong-Woon;Lee, Seong-Hyeok;Ryou, Hong-Sun;Yoon, Sung-Wook
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • In this study, the l/35 reduced-scale model experiment were conducted to investigate designed ventilation system performance at rescue station in tunnel fire. A model tunnel with 2 mm thick of steel, 10 m long, 0.19 m high and 0.26m was made by using Froude number scaling law. The cross-passages installing escape door at the center. were connected between accident tunnel and rescue tunnel. The n-heptane pool fire, $4cm\times4cm$, with heat release rate 698.97W were used as fire source. The fire source was located in the center and portal of accident tunnel as Worst case.. An operating ventilation system extracted smoke amount of 0.015 cms. The smoke temperature and carbon monoxide. concentration in cross-passage were measured to verify designed ventilation system. The results showed that, in center fire case without ventilation in accident tunnel, smoke did not propagated to rescue station. In portal tire case, smoke spreaded to rescue station without ventilation. But smoke did not propagated to rescue station with designed ventilation.

Ubiquitous system for fire escape: architecture and prototype (유비쿼터스 화재 대피 시스템: 구조 설계 및 프로토타입 개발)

  • Um, Ju-Myung;Yoon, Joo-Sung;Jeong, Su-Ho;Suh, Suk-Hwan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.05a
    • /
    • pp.806-809
    • /
    • 2007
  • 최근 화재, 수해, 테러 등의 안전사고가 증가하면서 건물 안전 시스템 구축을 위한 관심이 높아지고 있다. 이러한 시스템을 개발하는데 있어 유비쿼터스 컴퓨팅은 핵심 기술로 떠오르고 있다. 특히 화재시 건물 내 생존자를 안전한 경로로 대피하기 위한 시스템은 이미 여러 프로젝트에서 시범으로 보이고 있다. 이에 필요한 기능은 사용자 위치 인식, 화재 감지, 안전 경로 안내로 구성된다. 각 기능을 구현하기 위해 사용되는 장비는 생존자의 개별 인식에 이용하는 RFID 태그, 건물 내 각 방의 화재 상황을 감지하기 위한 센서네트워크 그리고 사용자 이동을 확인 할 수 있는 카메라로 구성되어 있다. 본 논문은 화재 상황에서 생존자를 대피하기 위한 안전 경로 시스템을 설계하고, 센서 네트워크와 RFID를 활용하여 프로토타입을 구축하며, 시뮬레이션을 통해 제안된 시스템의 유효성을 검증한다.

  • PDF